{"title":"FuseBox RCBOs, MCBs \u0026 Circuit Protection","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eComplete your distribution board with FuseBox protective devices designed to work alongside the FuseBox consumer unit range.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eCircuit protection options include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eType A RCBOs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMini RCBOs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBidirectional RCBOs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMCBs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRCDs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAFDDs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eType 2 surge protection devices\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMain switches\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFused switches\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstallation contactors\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThis extensive product range enables electricians to create a coordinated circuit protection solution using components designed as part of the FuseBox system.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"fusebox-6a-30ma-type-a-b-curve-6ka-rcbo-rta060630b","title":"FuseBox 6A 30mA Type A B Curve 6kA RCBO | RTA060630B","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eFuseBox 6A 30mA Type A B Curve 6kA RCBO | RTA060630B\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2\u003eSingle Module 6A Type A RCBO for FuseBox Consumer Units\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTA060630B\u003c\/strong\u003e is a \u003cstrong\u003e6A 30mA Type A RCBO\u003c\/strong\u003e designed to provide combined \u003cstrong\u003eovercurrent and residual current protection\u003c\/strong\u003e within FuseBox consumer units and compatible modular enclosures.\u003c\/p\u003e\n\u003cp\u003eCombining the functions of an \u003cstrong\u003eMCB and RCD in a single device\u003c\/strong\u003e, this RCBO protects against overloads, short circuits and earth leakage faults. Its \u003cstrong\u003eType A residual current characteristics\u003c\/strong\u003e allow detection of both AC and pulsating DC residual currents, making it suitable for modern electrical installations containing electronic equipment. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWith a \u003cstrong\u003eB Curve characteristic, 6kA short-circuit capacity and 30mA residual operating current\u003c\/strong\u003e, the RTA060630B provides reliable individual circuit protection while occupying just a single module within the consumer unit. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e6A Rated Current\u003c\/li\u003e\n\u003cli\u003e30mA Residual Operating Current\u003c\/li\u003e\n\u003cli\u003eType A Residual Current Protection\u003c\/li\u003e\n\u003cli\u003eB Curve Tripping Characteristic\u003c\/li\u003e\n\u003cli\u003e6kA Short-Circuit Breaking Capacity\u003c\/li\u003e\n\u003cli\u003eCombined Overload \u0026amp; Earth Leakage Protection\u003c\/li\u003e\n\u003cli\u003eProtects Against Short Circuits\u003c\/li\u003e\n\u003cli\u003eDetects AC \u0026amp; Pulsating DC Residual Currents\u003c\/li\u003e\n\u003cli\u003e1 Pole + Neutral Configuration\u003c\/li\u003e\n\u003cli\u003eSingle Module Design\u003c\/li\u003e\n\u003cli\u003e230V AC Rated Voltage\u003c\/li\u003e\n\u003cli\u003e50\/60Hz Frequency\u003c\/li\u003e\n\u003cli\u003eIP20 Rated\u003c\/li\u003e\n\u003cli\u003e35mm DIN Rail Mounting\u003c\/li\u003e\n\u003cli\u003eFlying Neutral Cable\u003c\/li\u003e\n\u003cli\u003eDesigned for FuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eComplies with IEC\/EN 61009-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCombined RCBO Circuit Protection\u003c\/h2\u003e\n\u003cp\u003eAn RCBO combines \u003cstrong\u003eresidual current protection and overcurrent protection\u003c\/strong\u003e within a single protective device.\u003c\/p\u003e\n\u003cp\u003eThe RTA060630B therefore provides protection against:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOverloads\u003c\/li\u003e\n\u003cli\u003eShort Circuits\u003c\/li\u003e\n\u003cli\u003eEarth Leakage \/ Residual Current Faults\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf an appropriate fault condition occurs, the RCBO disconnects the affected circuit, providing individual protection without relying on one shared RCD to protect several outgoing circuits. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eType A Residual Current Protection\u003c\/h2\u003e\n\u003cp\u003eThe RTA060630B is a \u003cstrong\u003eType A RCBO\u003c\/strong\u003e, designed to respond to \u003cstrong\u003eAC and pulsating DC residual currents\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eType A protection is particularly relevant to modern installations because many contemporary electrical and electronic appliances can produce residual currents with a pulsating DC component. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e6A B Curve Protection\u003c\/h2\u003e\n\u003cp\u003eRated at \u003cstrong\u003e6A\u003c\/strong\u003e, this model uses a \u003cstrong\u003eB Curve tripping characteristic\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIts rating makes it suitable for appropriately designed lower-current circuits, including applications such as lighting, subject to circuit design, cable selection and installation requirements. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e6kA Short-Circuit Capacity\u003c\/h2\u003e\n\u003cp\u003eThe RTA060630B has a rated \u003cstrong\u003e6kA short-circuit breaking capacity\u003c\/strong\u003e, providing protection against short-circuit fault currents within installations for which this rating is appropriate.\u003c\/p\u003e\n\u003cp\u003eFuseBox identifies the RTA series as its \u003cstrong\u003e6kA Type A RCBO range manufactured to BS\/IEC EN 61009-1\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSingle Module DIN Rail Design\u003c\/h2\u003e\n\u003cp\u003eThe RCBO uses a compact \u003cstrong\u003esingle-module format\u003c\/strong\u003e, helping maximise available space within the consumer unit.\u003c\/p\u003e\n\u003cp\u003eIt mounts onto a standard \u003cstrong\u003e35mm DIN rail\u003c\/strong\u003e and is specifically designed for use with FuseBox consumer units and modular enclosures. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e FuseBox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Code:\u003c\/strong\u003e RTA060630B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e RCBO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 6A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResidual Operating Current:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCD Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristic:\u003c\/strong\u003e B Curve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Short-Circuit Capacity:\u003c\/strong\u003e 6kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 230V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Rating:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Width:\u003c\/strong\u003e 1 Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e 35mm DIN Rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Incoming Terminal Capacity:\u003c\/strong\u003e 16mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Outgoing Terminal Capacity:\u003c\/strong\u003e 10mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e 114 x 17.8 x 69.6mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eDomestic Electrical Installations\u003c\/li\u003e\n\u003cli\u003eLighting Circuits\u003c\/li\u003e\n\u003cli\u003eResidential Properties\u003c\/li\u003e\n\u003cli\u003eNew-Build Installations\u003c\/li\u003e\n\u003cli\u003eConsumer Unit Upgrades\u003c\/li\u003e\n\u003cli\u003eCircuit Extensions\u003c\/li\u003e\n\u003cli\u003eIndividual Circuit Protection\u003c\/li\u003e\n\u003cli\u003eAppropriate Light Commercial Applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eElectrical circuit protection must always be selected according to the requirements of the circuit and applicable wiring regulations.\u003c\/p\u003e\n\u003ch2\u003eWhy Choose the FuseBox RTA060630B?\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTA060630B\u003c\/strong\u003e combines three important forms of circuit protection \u003cstrong\u003eoverload, short-circuit and residual current protection \u003c\/strong\u003ewithin one compact single-module device.\u003c\/p\u003e\n\u003cp\u003eIts \u003cstrong\u003e6A rating, B Curve characteristic, 30mA Type A residual protection and 6kA breaking capacity\u003c\/strong\u003e make it a practical choice for appropriately designed circuits within FuseBox consumer units.\u003c\/p\u003e\n\u003cp\u003eThe single-module DIN rail format also allows individual RCBO protection to be incorporated without unnecessarily consuming valuable space inside the consumer unit.\u003c\/p\u003e","brand":"FuseBox Consumer Units \u0026 Circuit Protection","offers":[{"title":"Default Title","offer_id":54694019793242,"sku":"RTA060630B","price":13.37,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/RTA_060630_B_fef9b50559.webp?v=1788434539"},{"product_id":"fusebox-10a-30ma-type-a-b-curve-6ka-rcbo-rta061030b","title":"FuseBox 10A 30mA Type A B Curve 6kA RCBO | RTA061030B","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eFuseBox 10A 30mA Type A B Curve 6kA RCBO | RTA061030B\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2\u003e10A Single Module Type A RCBO for FuseBox Consumer Units\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTA061030B\u003c\/strong\u003e is a \u003cstrong\u003e10A 30mA Type A B Curve RCBO\u003c\/strong\u003e designed to provide combined residual current and overcurrent protection within compatible FuseBox consumer units.\u003c\/p\u003e\n\u003cp\u003eCombining the functions of an \u003cstrong\u003eMCB and RCD in one compact protective device\u003c\/strong\u003e, the RTA061030B protects against \u003cstrong\u003eoverloads, short circuits and residual current earth leakage faults\u003c\/strong\u003e. Its Type A characteristics provide detection of AC and pulsating DC residual currents, making it suitable for modern electrical installations containing electronic equipment. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWith a \u003cstrong\u003e10A current rating, 30mA sensitivity, B Curve characteristic and 6kA breaking capacity\u003c\/strong\u003e, this single-module RCBO provides individual circuit protection without taking up unnecessary space inside the consumer unit.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e10A Rated Current\u003c\/li\u003e\n\u003cli\u003e30mA Residual Operating Current\u003c\/li\u003e\n\u003cli\u003eType A Residual Current Protection\u003c\/li\u003e\n\u003cli\u003eB Curve Tripping Characteristic\u003c\/li\u003e\n\u003cli\u003e6kA Short-Circuit Breaking Capacity\u003c\/li\u003e\n\u003cli\u003eCombined RCD \u0026amp; MCB Protection\u003c\/li\u003e\n\u003cli\u003eProtects Against Earth Leakage\u003c\/li\u003e\n\u003cli\u003eProtects Against Overloads\u003c\/li\u003e\n\u003cli\u003eProtects Against Short Circuits\u003c\/li\u003e\n\u003cli\u003eDetects AC \u0026amp; Pulsating DC Residual Currents\u003c\/li\u003e\n\u003cli\u003e1P + N Configuration\u003c\/li\u003e\n\u003cli\u003eCompact Single Module Design\u003c\/li\u003e\n\u003cli\u003e230V AC Rated Voltage\u003c\/li\u003e\n\u003cli\u003e50\/60Hz Operation\u003c\/li\u003e\n\u003cli\u003eIP20 Protection\u003c\/li\u003e\n\u003cli\u003e35mm DIN Rail Mounting\u003c\/li\u003e\n\u003cli\u003e450mm Flying Neutral Cable\u003c\/li\u003e\n\u003cli\u003eDesigned for FuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eComplies with IEC\/EN 61009-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFuseBox's technical data identifies \u003cstrong\u003eRTA061030B specifically as the 10A model\u003c\/strong\u003e in its 30mA Type A, B Curve, 6kA RCBO range. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eCombined RCBO Circuit Protection\u003c\/h2\u003e\n\u003cp\u003eAn RCBO combines two important forms of electrical protection within one device: \u003cstrong\u003eovercurrent protection and residual current protection\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe RTA061030B therefore provides protection against:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOverloads\u003c\/li\u003e\n\u003cli\u003eShort Circuits\u003c\/li\u003e\n\u003cli\u003eEarth Leakage \/ Residual Current Faults\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProviding RCBO protection to individual circuits also means a fault can be isolated at the affected circuit rather than relying on one shared RCD protecting multiple circuits.\u003c\/p\u003e\n\u003ch2\u003eType A Residual Current Protection\u003c\/h2\u003e\n\u003cp\u003eThe RTA061030B is a \u003cstrong\u003eType A RCBO\u003c\/strong\u003e, designed to respond to both \u003cstrong\u003eAC and pulsating DC residual currents\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eFuseBox specifies its residual current characteristics as Type A for AC and pulsating DC up to 6mA. This makes Type A protection particularly relevant to modern electrical installations containing equipment with electronic components. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e10A B Curve Protection\u003c\/h2\u003e\n\u003cp\u003eThis model has a rated current of \u003cstrong\u003e10A\u003c\/strong\u003e and uses a \u003cstrong\u003eB Curve tripping characteristic of 3–5 In\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe 10A rating makes the RTA061030B suitable for appropriately designed circuits where this level of overcurrent protection is required. Circuit protection should always be selected according to cable size, load characteristics and the requirements of the electrical installation.\u003c\/p\u003e\n\u003ch2\u003e6kA Short-Circuit Breaking Capacity\u003c\/h2\u003e\n\u003cp\u003eThe RTA061030B has a rated short-circuit breaking capacity of \u003cstrong\u003e6000A (6kA)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis allows the RCBO to provide short-circuit protection within electrical installations where a 6kA rated device is appropriate. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eCompact Single Module Design\u003c\/h2\u003e\n\u003cp\u003eThe RTA061030B occupies just \u003cstrong\u003eone module\u003c\/strong\u003e, helping installers maximise available space inside the consumer unit.\u003c\/p\u003e\n\u003cp\u003eWith dimensions of approximately \u003cstrong\u003e114 x 17.8 x 69.6mm\u003c\/strong\u003e, the RCBO mounts onto a standard \u003cstrong\u003e35mm DIN rail\u003c\/strong\u003e and incorporates a flying neutral connection. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e FuseBox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Code:\u003c\/strong\u003e RTA061030B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e RCBO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 10A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Residual Operating Current:\u003c\/strong\u003e 30mA \/ 0.03A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCD Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResidual Current Characteristics:\u003c\/strong\u003e AC \u0026amp; Pulsating DC up to 6mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristic:\u003c\/strong\u003e B Curve, 3–5 In\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Breaking Capacity:\u003c\/strong\u003e 6000A \/ 6kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 230V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Degree:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Modules:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e 35mm DIN Rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Incoming Terminal Capacity:\u003c\/strong\u003e 1–16mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Outgoing Terminal Capacity:\u003c\/strong\u003e 1–10mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncoming Recommended Tightening Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutgoing Recommended Tightening Torque:\u003c\/strong\u003e 1.2Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlying Neutral Cable Length:\u003c\/strong\u003e 450mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Endurance:\u003c\/strong\u003e 10,000 Operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e PA6 \/ Nylon 6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e 114 x 17.8 x 69.6mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eDomestic Electrical Installations\u003c\/li\u003e\n\u003cli\u003eLighting Circuits Where Appropriately Designed\u003c\/li\u003e\n\u003cli\u003eResidential Properties\u003c\/li\u003e\n\u003cli\u003eNew-Build Electrical Installations\u003c\/li\u003e\n\u003cli\u003eConsumer Unit Upgrades\u003c\/li\u003e\n\u003cli\u003eCircuit Extensions\u003c\/li\u003e\n\u003cli\u003eIndividual Circuit Protection\u003c\/li\u003e\n\u003cli\u003eAppropriate Light Commercial Installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose the FuseBox RTA061030B?\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTA061030B\u003c\/strong\u003e provides \u003cstrong\u003eoverload, short-circuit and 30mA residual current protection\u003c\/strong\u003e within one compact protective device.\u003c\/p\u003e\n\u003cp\u003eIts combination of a \u003cstrong\u003e10A rating, B Curve characteristic, Type A residual current protection and 6kA breaking capacity\u003c\/strong\u003e makes it a versatile option for appropriately designed circuits within FuseBox consumer units.\u003c\/p\u003e\n\u003cp\u003eThe compact \u003cstrong\u003esingle-module DIN rail design\u003c\/strong\u003e also makes efficient use of consumer unit space while providing individual RCBO protection for the connected circuit.\u003c\/p\u003e","brand":"FuseBox Consumer Units \u0026 Circuit Protection","offers":[{"title":"Default Title","offer_id":54694053609818,"sku":"RTA061030B","price":13.37,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/RTA_060630_B_fef9b50559.webp?v=1788434539"},{"product_id":"fusebox-16a-30ma-type-a-b-curve-6ka-rcbo-rta061630b","title":"FuseBox 16A 30mA Type A B Curve 6kA RCBO | RTA061630B","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eFuseBox 16A 30mA Type A B Curve 6kA RCBO | RTA061630B\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2\u003e16A Single Module Type A RCBO for FuseBox Consumer Units\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTA061630B\u003c\/strong\u003e is a \u003cstrong\u003e16A 30mA Type A B Curve RCBO\u003c\/strong\u003e designed to provide combined residual current and overcurrent protection within compatible FuseBox consumer units.\u003c\/p\u003e\n\u003cp\u003eCombining the functions of an \u003cstrong\u003eMCB and RCD within one compact device\u003c\/strong\u003e, the RTA061630B provides protection against \u003cstrong\u003eoverloads, short circuits and earth leakage faults\u003c\/strong\u003e. Its Type A characteristics enable detection of both AC and pulsating DC residual currents, making it suitable for modern electrical installations incorporating electronic equipment. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWith a \u003cstrong\u003e16A current rating, 30mA sensitivity, B Curve characteristic and 6kA breaking capacity\u003c\/strong\u003e, this single-module RCBO provides effective individual circuit protection while making efficient use of space inside the consumer unit.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e16A Rated Current\u003c\/li\u003e\n\u003cli\u003e30mA Residual Operating Current\u003c\/li\u003e\n\u003cli\u003eType A Residual Current Protection\u003c\/li\u003e\n\u003cli\u003eB Curve Tripping Characteristic\u003c\/li\u003e\n\u003cli\u003e6kA Short-Circuit Breaking Capacity\u003c\/li\u003e\n\u003cli\u003eCombined RCD \u0026amp; MCB Protection\u003c\/li\u003e\n\u003cli\u003eProtects Against Earth Leakage\u003c\/li\u003e\n\u003cli\u003eProtects Against Overloads\u003c\/li\u003e\n\u003cli\u003eProtects Against Short Circuits\u003c\/li\u003e\n\u003cli\u003eDetects AC \u0026amp; Pulsating DC Residual Currents\u003c\/li\u003e\n\u003cli\u003e1P + N Configuration\u003c\/li\u003e\n\u003cli\u003eCompact Single Module Design\u003c\/li\u003e\n\u003cli\u003e230V AC Rated Voltage\u003c\/li\u003e\n\u003cli\u003e50\/60Hz Operation\u003c\/li\u003e\n\u003cli\u003eIP20 Protection\u003c\/li\u003e\n\u003cli\u003e35mm DIN Rail Mounting\u003c\/li\u003e\n\u003cli\u003e450mm Flying Neutral Cable\u003c\/li\u003e\n\u003cli\u003eDesigned for FuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eManufactured to IEC\/EN 61009-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFuseBox's technical documentation identifies \u003cstrong\u003eRTA061630B as the 16A model\u003c\/strong\u003e within its Type A, B Curve, 30mA, 6kA RCBO range. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eCombined RCBO Circuit Protection\u003c\/h2\u003e\n\u003cp\u003eAn RCBO combines \u003cstrong\u003eresidual current protection and overcurrent protection\u003c\/strong\u003e within one protective device.\u003c\/p\u003e\n\u003cp\u003eThe RTA061630B therefore provides protection against three key electrical fault conditions: \u003cstrong\u003eoverloads, short circuits and residual current \/ earth leakage faults\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eIndividual RCBO protection also allows a fault to be isolated to the affected circuit rather than relying on a shared RCD protecting several outgoing circuits.\u003c\/p\u003e\n\u003ch2\u003eType A Residual Current Protection\u003c\/h2\u003e\n\u003cp\u003eThe RTA061630B is a \u003cstrong\u003eType A RCBO\u003c\/strong\u003e, designed to respond to both AC and pulsating DC residual currents.\u003c\/p\u003e\n\u003cp\u003eFuseBox specifies the device as \u003cstrong\u003eType A for AC and pulsating DC residual currents up to 6mA\u003c\/strong\u003e, making it appropriate for many modern electrical installations incorporating electronic loads. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e16A B Curve Protection\u003c\/h2\u003e\n\u003cp\u003eThis model has a rated current of \u003cstrong\u003e16A\u003c\/strong\u003e and a \u003cstrong\u003eB Curve tripping characteristic of 3–5 In\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eIts 16A rating makes the RTA061630B suitable for appropriately designed circuits requiring this level of overcurrent protection. Selection should always be based on circuit design, connected load, cable characteristics and applicable wiring requirements.\u003c\/p\u003e\n\u003ch2\u003e6kA Breaking Capacity\u003c\/h2\u003e\n\u003cp\u003eThe RTA061630B provides a rated short-circuit breaking capacity of \u003cstrong\u003e6000A (6kA)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis enables the RCBO to provide short-circuit protection in installations where a 6kA protective device is appropriate. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eCompact Single Module Design\u003c\/h2\u003e\n\u003cp\u003eOccupying just \u003cstrong\u003eone module\u003c\/strong\u003e, the RTA061630B allows individual RCBO protection to be installed without unnecessarily consuming space inside the consumer unit.\u003c\/p\u003e\n\u003cp\u003eThe device is designed for \u003cstrong\u003e35mm DIN rail mounting\u003c\/strong\u003e and incorporates a \u003cstrong\u003e450mm flying neutral cable\u003c\/strong\u003e for connection within the consumer unit. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e FuseBox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Code:\u003c\/strong\u003e RTA061630B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e RCBO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Residual Operating Current:\u003c\/strong\u003e 30mA \/ 0.03A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCD Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResidual Current Characteristics:\u003c\/strong\u003e AC \u0026amp; Pulsating DC up to 6mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristic:\u003c\/strong\u003e B Curve, 3–5 In\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Breaking Capacity:\u003c\/strong\u003e 6000A \/ 6kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 230V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Degree:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Modules:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e 35mm DIN Rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Incoming Terminal Capacity:\u003c\/strong\u003e 1–16mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Outgoing Terminal Capacity:\u003c\/strong\u003e 1–10mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncoming Recommended Tightening Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutgoing Recommended Tightening Torque:\u003c\/strong\u003e 1.2Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlying Neutral Cable Length:\u003c\/strong\u003e 450mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Endurance:\u003c\/strong\u003e 10,000 Operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e PA6 \/ Nylon 6\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eDomestic Electrical Installations\u003c\/li\u003e\n\u003cli\u003eAppropriate 16A Final Circuits\u003c\/li\u003e\n\u003cli\u003eResidential Properties\u003c\/li\u003e\n\u003cli\u003eNew-Build Electrical Installations\u003c\/li\u003e\n\u003cli\u003eConsumer Unit Upgrades\u003c\/li\u003e\n\u003cli\u003eCircuit Extensions\u003c\/li\u003e\n\u003cli\u003eIndividual Circuit Protection\u003c\/li\u003e\n\u003cli\u003eAppropriate Light Commercial Installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose the FuseBox RTA061630B?\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTA061630B\u003c\/strong\u003e provides three important forms of electrical protection within one compact device: \u003cstrong\u003eoverload, short-circuit and 30mA residual current protection\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIts combination of a \u003cstrong\u003e16A rating, B Curve characteristic, Type A residual protection and 6kA breaking capacity\u003c\/strong\u003e makes it a practical choice for appropriately designed circuits within FuseBox consumer units.\u003c\/p\u003e\n\u003cp\u003eThe compact single-module format also helps maximise available consumer unit space while allowing individual circuits to benefit from dedicated RCBO protection.\u003c\/p\u003e","brand":"FuseBox Consumer Units \u0026 Circuit Protection","offers":[{"title":"Default Title","offer_id":54694286295386,"sku":"RTA061630B","price":13.37,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/RTA_060630_B_fef9b50559_1c4e17f3-dfd9-46ef-ba4e-b0daa00fbf29.webp?v=1788437132"},{"product_id":"fusebox-20a-30ma-type-a-b-curve-6ka-rcbo-rta062030b","title":"FuseBox 20A 30mA Type A B Curve 6kA RCBO | RTA062030B","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eFuseBox 20A 30mA Type A B Curve 6kA RCBO | RTA062030B\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2\u003e20A Single Module Type A RCBO for FuseBox Consumer Units\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTA062030B\u003c\/strong\u003e is a \u003cstrong\u003e20A 30mA Type A B Curve RCBO\u003c\/strong\u003e designed to provide combined residual current and overcurrent protection for individual circuits within compatible FuseBox consumer units.\u003c\/p\u003e\n\u003cp\u003eCombining the functions of an \u003cstrong\u003eMCB and RCD in one compact protective device\u003c\/strong\u003e, the RTA062030B protects against \u003cstrong\u003eoverloads, short circuits and residual current \/ earth leakage faults\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eWith a \u003cstrong\u003e20A rated current, 30mA residual operating current, Type A characteristics, B Curve tripping and 6kA breaking capacity\u003c\/strong\u003e, it provides comprehensive circuit protection while occupying just a single module within the consumer unit.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e20A Rated Current\u003c\/li\u003e\n\u003cli\u003e30mA Residual Operating Current\u003c\/li\u003e\n\u003cli\u003eType A Residual Current Protection\u003c\/li\u003e\n\u003cli\u003eB Curve Tripping Characteristic\u003c\/li\u003e\n\u003cli\u003e6kA Short-Circuit Breaking Capacity\u003c\/li\u003e\n\u003cli\u003eCombined RCD \u0026amp; MCB Protection\u003c\/li\u003e\n\u003cli\u003eProtects Against Earth Leakage Faults\u003c\/li\u003e\n\u003cli\u003eProtects Against Overloads\u003c\/li\u003e\n\u003cli\u003eProtects Against Short Circuits\u003c\/li\u003e\n\u003cli\u003eType A Detection for AC \u0026amp; Pulsating DC Residual Currents\u003c\/li\u003e\n\u003cli\u003e1P + N Configuration\u003c\/li\u003e\n\u003cli\u003eCompact Single Module Design\u003c\/li\u003e\n\u003cli\u003e230V AC Rated Voltage\u003c\/li\u003e\n\u003cli\u003e50\/60Hz Operation\u003c\/li\u003e\n\u003cli\u003eIP20 Protection\u003c\/li\u003e\n\u003cli\u003e35mm DIN Rail Mounting\u003c\/li\u003e\n\u003cli\u003eFlying Neutral Connection\u003c\/li\u003e\n\u003cli\u003eDesigned for FuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eManufactured to IEC\/EN 61009-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCombined RCBO Protection\u003c\/h2\u003e\n\u003cp\u003eAn RCBO combines \u003cstrong\u003eovercurrent protection and residual current protection\u003c\/strong\u003e within a single device.\u003c\/p\u003e\n\u003cp\u003eThe FuseBox RTA062030B therefore provides protection against:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOverloads\u003c\/li\u003e\n\u003cli\u003eShort Circuits\u003c\/li\u003e\n\u003cli\u003eResidual Current \/ Earth Leakage Faults\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUsing individual RCBOs also allows protection to be provided on a circuit-by-circuit basis rather than several circuits sharing a single RCD.\u003c\/p\u003e\n\u003ch2\u003eType A Residual Current Protection\u003c\/h2\u003e\n\u003cp\u003eThe RTA062030B features \u003cstrong\u003eType A residual current protection\u003c\/strong\u003e, allowing it to respond to both sinusoidal AC and pulsating DC residual currents.\u003c\/p\u003e\n\u003cp\u003eThis makes Type A protection particularly relevant to modern electrical installations, where many appliances and electronic devices can produce residual current waveforms beyond purely sinusoidal AC.\u003c\/p\u003e\n\u003ch2\u003e20A B Curve Protection\u003c\/h2\u003e\n\u003cp\u003eThis model has a rated current of \u003cstrong\u003e20A\u003c\/strong\u003e and uses a \u003cstrong\u003eB Curve tripping characteristic\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe 20A rating makes it suitable for appropriately designed final circuits requiring this level of overcurrent protection.\u003c\/p\u003e\n\u003cp\u003eProtective device selection should always take account of the connected load, cable size, installation method and applicable wiring requirements.\u003c\/p\u003e\n\u003ch2\u003e6kA Short-Circuit Breaking Capacity\u003c\/h2\u003e\n\u003cp\u003eThe RTA062030B has a rated short-circuit breaking capacity of \u003cstrong\u003e6000A \/ 6kA\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis provides short-circuit protection for installations where a 6kA rated protective device is appropriate.\u003c\/p\u003e\n\u003ch2\u003eCompact Single Module Design\u003c\/h2\u003e\n\u003cp\u003eOccupying only \u003cstrong\u003eone module\u003c\/strong\u003e, the RTA062030B helps maximise the available space within a FuseBox consumer unit.\u003c\/p\u003e\n\u003cp\u003eThe RCBO is designed for mounting onto a standard \u003cstrong\u003e35mm DIN rail\u003c\/strong\u003e and incorporates a flying neutral connection for installation within the distribution board.\u003c\/p\u003e\n\u003ch2\u003eIndividual Circuit Protection\u003c\/h2\u003e\n\u003cp\u003eRCBOs provide residual current and overcurrent protection to each individual circuit.\u003c\/p\u003e\n\u003cp\u003eThis approach can improve circuit separation because an electrical fault can operate the RCBO protecting the affected circuit rather than relying on a shared RCD protecting multiple outgoing circuits.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e FuseBox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Code:\u003c\/strong\u003e RTA062030B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e RCBO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 20A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Residual Operating Current:\u003c\/strong\u003e 30mA \/ 0.03A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCD Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResidual Current Detection:\u003c\/strong\u003e AC \u0026amp; Pulsating DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristic:\u003c\/strong\u003e B Curve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Breaking Capacity:\u003c\/strong\u003e 6000A \/ 6kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 230V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Degree:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Modules:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e 35mm DIN Rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Incoming Terminal Capacity:\u003c\/strong\u003e 16mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Outgoing Terminal Capacity:\u003c\/strong\u003e 10mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncoming Recommended Tightening Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutgoing Recommended Tightening Torque:\u003c\/strong\u003e 1.2Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlying Neutral Cable Length:\u003c\/strong\u003e 450mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Endurance:\u003c\/strong\u003e 10,000 Operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e PA6 \/ Nylon 6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eDomestic Electrical Installations\u003c\/li\u003e\n\u003cli\u003eAppropriate 20A Final Circuits\u003c\/li\u003e\n\u003cli\u003eResidential Properties\u003c\/li\u003e\n\u003cli\u003eNew-Build Electrical Installations\u003c\/li\u003e\n\u003cli\u003eConsumer Unit Replacements \u0026amp; Upgrades\u003c\/li\u003e\n\u003cli\u003eCircuit Extensions\u003c\/li\u003e\n\u003cli\u003eIndividual Circuit Protection\u003c\/li\u003e\n\u003cli\u003eAppropriate Light Commercial Installations\u003c\/li\u003e\n\u003cli\u003eElectrical Distribution Upgrades\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose the FuseBox RTA062030B?\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTA062030B\u003c\/strong\u003e combines \u003cstrong\u003eoverload, short-circuit and 30mA residual current protection\u003c\/strong\u003e within one compact protective device.\u003c\/p\u003e\n\u003cp\u003eIts \u003cstrong\u003e20A rating, B Curve characteristic, Type A residual protection and 6kA breaking capacity\u003c\/strong\u003e make it a practical solution for appropriately designed circuits within FuseBox consumer units.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003esingle-module DIN rail design\u003c\/strong\u003e also makes efficient use of available consumer unit space while providing dedicated RCBO protection to the individual circuit.\u003c\/p\u003e","brand":"FuseBox Consumer Units \u0026 Circuit Protection","offers":[{"title":"Default Title","offer_id":54694296420698,"sku":"RTA062030B","price":13.37,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/RTA_060630_B_fef9b50559_1c4e17f3-dfd9-46ef-ba4e-b0daa00fbf29.webp?v=1788437132"},{"product_id":"fusebox-25a-30ma-type-a-b-curve-6ka-rcbo-rta062530b","title":"FuseBox 25A 30mA Type A B Curve 6kA RCBO | RTA062530B","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eFuseBox 25A 30mA Type A B Curve 6kA RCBO | RTA062530B\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2\u003e25A Single Module Type A RCBO for FuseBox Consumer Units\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTA062530B\u003c\/strong\u003e is a \u003cstrong\u003e25A 30mA Type A B Curve RCBO\u003c\/strong\u003e designed to provide combined overcurrent and residual current protection for individual circuits within compatible FuseBox consumer units.\u003c\/p\u003e\n\u003cp\u003eBy combining the functions of an \u003cstrong\u003eMCB and RCD in a single compact device\u003c\/strong\u003e, the RTA062530B provides protection against \u003cstrong\u003eoverloads, short circuits and residual current \/ earth leakage faults\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eWith its \u003cstrong\u003e25A rated current, 30mA residual operating current, Type A characteristics, B Curve tripping and 6kA breaking capacity\u003c\/strong\u003e, this RCBO provides comprehensive individual circuit protection while occupying just one module within the consumer unit.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e25A Rated Current\u003c\/li\u003e\n\u003cli\u003e30mA Residual Operating Current\u003c\/li\u003e\n\u003cli\u003eType A Residual Current Protection\u003c\/li\u003e\n\u003cli\u003eB Curve Tripping Characteristic\u003c\/li\u003e\n\u003cli\u003e6kA Short-Circuit Breaking Capacity\u003c\/li\u003e\n\u003cli\u003eCombined RCD \u0026amp; MCB Protection\u003c\/li\u003e\n\u003cli\u003eProtects Against Overloads\u003c\/li\u003e\n\u003cli\u003eProtects Against Short Circuits\u003c\/li\u003e\n\u003cli\u003eProtects Against Earth Leakage Faults\u003c\/li\u003e\n\u003cli\u003eDetects AC \u0026amp; Pulsating DC Residual Currents\u003c\/li\u003e\n\u003cli\u003e1P + N Configuration\u003c\/li\u003e\n\u003cli\u003eCompact Single Module Design\u003c\/li\u003e\n\u003cli\u003e230V AC Rated Voltage\u003c\/li\u003e\n\u003cli\u003e50\/60Hz Operation\u003c\/li\u003e\n\u003cli\u003eIP20 Protection\u003c\/li\u003e\n\u003cli\u003e35mm DIN Rail Mounting\u003c\/li\u003e\n\u003cli\u003eFlying Neutral Connection\u003c\/li\u003e\n\u003cli\u003eDesigned for FuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eManufactured to IEC\/EN 61009-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCombined RCBO Circuit Protection\u003c\/h2\u003e\n\u003cp\u003eThe FuseBox RTA062530B combines \u003cstrong\u003eresidual current protection and overcurrent protection\u003c\/strong\u003e within a single modular device.\u003c\/p\u003e\n\u003cp\u003eThis allows the RCBO to provide protection against three key electrical fault conditions:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOverloads\u003c\/li\u003e\n\u003cli\u003eShort Circuits\u003c\/li\u003e\n\u003cli\u003eResidual Current \/ Earth Leakage Faults\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUsing individual RCBOs also provides circuit-by-circuit protection, helping isolate an electrical fault to the affected circuit rather than relying on a shared RCD protecting multiple circuits.\u003c\/p\u003e\n\u003ch2\u003eType A Residual Current Protection\u003c\/h2\u003e\n\u003cp\u003eThe RTA062530B provides \u003cstrong\u003eType A residual current protection\u003c\/strong\u003e, allowing it to respond to both AC and pulsating DC residual currents.\u003c\/p\u003e\n\u003cp\u003eType A protection is particularly relevant in modern installations where electronic equipment can generate residual currents with characteristics beyond purely sinusoidal AC.\u003c\/p\u003e\n\u003cp\u003eCombined with a \u003cstrong\u003e30mA rated residual operating current\u003c\/strong\u003e, the RTA062530B provides additional protection for appropriately designed circuits.\u003c\/p\u003e\n\u003ch2\u003e25A B Curve Protection\u003c\/h2\u003e\n\u003cp\u003eThis model has a rated current of \u003cstrong\u003e25A\u003c\/strong\u003e and uses a \u003cstrong\u003eB Curve tripping characteristic\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIts 25A rating makes it suitable for appropriately designed circuits requiring this level of overcurrent protection.\u003c\/p\u003e\n\u003cp\u003eThe correct protective device should always be selected according to the connected load, cable size, installation method and applicable electrical installation requirements.\u003c\/p\u003e\n\u003ch2\u003e6kA Short-Circuit Breaking Capacity\u003c\/h2\u003e\n\u003cp\u003eThe RTA062530B has a rated short-circuit breaking capacity of \u003cstrong\u003e6000A \/ 6kA\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis allows the device to provide short-circuit protection within installations where a 6kA rated protective device is appropriate.\u003c\/p\u003e\n\u003ch2\u003eCompact Single Module Design\u003c\/h2\u003e\n\u003cp\u003eThe RTA062530B occupies just \u003cstrong\u003eone module\u003c\/strong\u003e, helping maximise the available space within a FuseBox consumer unit.\u003c\/p\u003e\n\u003cp\u003eIts compact format makes it particularly useful where several circuits require individual RCBO protection while keeping the overall distribution board installation neat and space-efficient.\u003c\/p\u003e\n\u003cp\u003eThe device mounts onto a standard \u003cstrong\u003e35mm DIN rail\u003c\/strong\u003e and incorporates a flying neutral connection.\u003c\/p\u003e\n\u003ch2\u003eIndividual Circuit Protection\u003c\/h2\u003e\n\u003cp\u003eUsing RCBOs on individual outgoing circuits can provide improved circuit separation compared with arrangements where several circuits share a common RCD.\u003c\/p\u003e\n\u003cp\u003eIf an appropriate fault occurs, the RCBO protecting the affected circuit can operate independently, helping minimise disruption to other separately protected circuits within the consumer unit.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e FuseBox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Code:\u003c\/strong\u003e RTA062530B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e RCBO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 25A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Residual Operating Current:\u003c\/strong\u003e 30mA \/ 0.03A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCD Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResidual Current Detection:\u003c\/strong\u003e AC \u0026amp; Pulsating DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristic:\u003c\/strong\u003e B Curve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Breaking Capacity:\u003c\/strong\u003e 6000A \/ 6kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 230V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Degree:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Modules:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e 35mm DIN Rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Incoming Terminal Capacity:\u003c\/strong\u003e 16mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Outgoing Terminal Capacity:\u003c\/strong\u003e 10mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncoming Recommended Tightening Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutgoing Recommended Tightening Torque:\u003c\/strong\u003e 1.2Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlying Neutral Cable Length:\u003c\/strong\u003e 450mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Endurance:\u003c\/strong\u003e 10,000 Operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e PA6 \/ Nylon 6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eDomestic Electrical Installations\u003c\/li\u003e\n\u003cli\u003eAppropriate 25A Final Circuits\u003c\/li\u003e\n\u003cli\u003eResidential Properties\u003c\/li\u003e\n\u003cli\u003eNew-Build Electrical Installations\u003c\/li\u003e\n\u003cli\u003eConsumer Unit Replacements\u003c\/li\u003e\n\u003cli\u003eConsumer Unit Upgrades\u003c\/li\u003e\n\u003cli\u003eCircuit Extensions\u003c\/li\u003e\n\u003cli\u003eIndividual Circuit Protection\u003c\/li\u003e\n\u003cli\u003eAppropriate Light Commercial Installations\u003c\/li\u003e\n\u003cli\u003eElectrical Distribution Upgrades\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose the FuseBox RTA062530B?\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTA062530B\u003c\/strong\u003e provides \u003cstrong\u003eoverload, short-circuit and 30mA residual current protection\u003c\/strong\u003e within a single compact protective device.\u003c\/p\u003e\n\u003cp\u003eIts combination of a \u003cstrong\u003e25A rating, B Curve characteristic, Type A residual protection and 6kA breaking capacity\u003c\/strong\u003e makes it a practical choice for appropriately designed circuits within FuseBox consumer units.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003esingle-module DIN rail format\u003c\/strong\u003e also makes efficient use of available consumer unit space while allowing individual circuits to benefit from dedicated RCBO protection.\u003c\/p\u003e","brand":"FuseBox Consumer Units \u0026 Circuit Protection","offers":[{"title":"Default Title","offer_id":54694305988954,"sku":"RTA062530B","price":13.37,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/RTA_060630_B_fef9b50559_1c4e17f3-dfd9-46ef-ba4e-b0daa00fbf29.webp?v=1788437132"},{"product_id":"fusebox-32a-30ma-type-a-b-curve-6ka-rcbo-rta063230b","title":"FuseBox 32A 30mA Type A B Curve 6kA RCBO | RTA063230B","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eFuseBox 32A 30mA Type A B Curve 6kA RCBO | RTA063230B\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2\u003e32A Single Module Type A RCBO for FuseBox Consumer Units\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTA063230B\u003c\/strong\u003e is a \u003cstrong\u003e32A 30mA Type A B Curve RCBO\u003c\/strong\u003e designed to provide combined residual current and overcurrent protection for individual circuits within compatible FuseBox consumer units.\u003c\/p\u003e\n\u003cp\u003eCombining the functions of an \u003cstrong\u003eMCB and RCD in one compact protective device\u003c\/strong\u003e, the RTA063230B protects against \u003cstrong\u003eoverloads, short circuits and residual current \/ earth leakage faults\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eWith a \u003cstrong\u003e32A rated current, 30mA residual operating current, Type A characteristics, B Curve tripping and 6kA breaking capacity\u003c\/strong\u003e, this RCBO provides comprehensive individual circuit protection while occupying only a single module within the consumer unit.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e32A Rated Current\u003c\/li\u003e\n\u003cli\u003e30mA Residual Operating Current\u003c\/li\u003e\n\u003cli\u003eType A Residual Current Protection\u003c\/li\u003e\n\u003cli\u003eB Curve Tripping Characteristic\u003c\/li\u003e\n\u003cli\u003e6kA Short-Circuit Breaking Capacity\u003c\/li\u003e\n\u003cli\u003eCombined RCD \u0026amp; MCB Protection\u003c\/li\u003e\n\u003cli\u003eProtects Against Overloads\u003c\/li\u003e\n\u003cli\u003eProtects Against Short Circuits\u003c\/li\u003e\n\u003cli\u003eProtects Against Earth Leakage Faults\u003c\/li\u003e\n\u003cli\u003eDetects AC \u0026amp; Pulsating DC Residual Currents\u003c\/li\u003e\n\u003cli\u003e1P + N Configuration\u003c\/li\u003e\n\u003cli\u003eCompact Single Module Design\u003c\/li\u003e\n\u003cli\u003e230V AC Rated Voltage\u003c\/li\u003e\n\u003cli\u003e50\/60Hz Operation\u003c\/li\u003e\n\u003cli\u003eIP20 Protection\u003c\/li\u003e\n\u003cli\u003e35mm DIN Rail Mounting\u003c\/li\u003e\n\u003cli\u003e450mm Flying Neutral Connection\u003c\/li\u003e\n\u003cli\u003eDesigned for FuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eManufactured to IEC\/EN 61009-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCombined RCBO Circuit Protection\u003c\/h2\u003e\n\u003cp\u003eThe FuseBox RTA063230B combines \u003cstrong\u003eresidual current protection and overcurrent protection\u003c\/strong\u003e within a single modular device.\u003c\/p\u003e\n\u003cp\u003eThis allows one RCBO to provide protection against three important electrical fault conditions:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOverloads\u003c\/li\u003e\n\u003cli\u003eShort Circuits\u003c\/li\u003e\n\u003cli\u003eResidual Current \/ Earth Leakage Faults\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProviding individual RCBO protection to outgoing circuits also helps improve circuit separation compared with arrangements where multiple circuits share a common RCD.\u003c\/p\u003e\n\u003ch2\u003eType A Residual Current Protection\u003c\/h2\u003e\n\u003cp\u003eThe RTA063230B provides \u003cstrong\u003eType A residual current protection\u003c\/strong\u003e, allowing the device to respond to both AC and pulsating DC residual currents.\u003c\/p\u003e\n\u003cp\u003eThis is particularly relevant to modern electrical installations, where electronic equipment and appliances can produce residual current waveforms beyond purely sinusoidal AC.\u003c\/p\u003e\n\u003cp\u003eCombined with a \u003cstrong\u003e30mA rated residual operating current\u003c\/strong\u003e, the RTA063230B provides additional residual current protection for appropriately designed circuits.\u003c\/p\u003e\n\u003ch2\u003e32A B Curve Protection\u003c\/h2\u003e\n\u003cp\u003eThe RTA063230B has a \u003cstrong\u003e32A rated current\u003c\/strong\u003e and uses a \u003cstrong\u003eB Curve tripping characteristic\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eA 32A protective device is commonly specified for appropriately designed final circuits where the circuit load, conductor size and installation conditions require this rating.\u003c\/p\u003e\n\u003cp\u003eCorrect circuit protection must always be selected according to the electrical design, cable characteristics, connected load and applicable wiring requirements.\u003c\/p\u003e\n\u003ch2\u003e6kA Short-Circuit Breaking Capacity\u003c\/h2\u003e\n\u003cp\u003eThe RTA063230B has a rated short-circuit breaking capacity of \u003cstrong\u003e6000A \/ 6kA\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis enables the RCBO to provide short-circuit protection within electrical installations where a 6kA rated protective device is appropriate.\u003c\/p\u003e\n\u003ch2\u003eCompact Single Module Design\u003c\/h2\u003e\n\u003cp\u003eDespite combining residual current and overcurrent protection, the RTA063230B occupies only \u003cstrong\u003eone module\u003c\/strong\u003e within the consumer unit.\u003c\/p\u003e\n\u003cp\u003eIts compact format helps maximise available space, particularly in installations where numerous circuits require individual RCBO protection.\u003c\/p\u003e\n\u003cp\u003eThe device mounts onto a standard \u003cstrong\u003e35mm DIN rail\u003c\/strong\u003e and incorporates a \u003cstrong\u003e450mm flying neutral connection\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eIndividual Circuit Protection\u003c\/h2\u003e\n\u003cp\u003eUsing RCBOs on individual circuits can improve circuit separation and help minimise disruption if a fault develops.\u003c\/p\u003e\n\u003cp\u003eRather than several circuits relying on a shared RCD, each appropriately protected circuit can have its own RCBO. A fault on one circuit can therefore operate its dedicated protective device without directly relying on the residual current protection serving other circuits.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e FuseBox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Code:\u003c\/strong\u003e RTA063230B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e RCBO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 32A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Residual Operating Current:\u003c\/strong\u003e 30mA \/ 0.03A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCD Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResidual Current Detection:\u003c\/strong\u003e AC \u0026amp; Pulsating DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristic:\u003c\/strong\u003e B Curve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Breaking Capacity:\u003c\/strong\u003e 6000A \/ 6kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 230V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Degree:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Modules:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e 35mm DIN Rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Incoming Terminal Capacity:\u003c\/strong\u003e 16mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Outgoing Terminal Capacity:\u003c\/strong\u003e 10mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncoming Recommended Tightening Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutgoing Recommended Tightening Torque:\u003c\/strong\u003e 1.2Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlying Neutral Cable Length:\u003c\/strong\u003e 450mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Endurance:\u003c\/strong\u003e 10,000 Operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e PA6 \/ Nylon 6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eDomestic Electrical Installations\u003c\/li\u003e\n\u003cli\u003eAppropriate 32A Final Circuits\u003c\/li\u003e\n\u003cli\u003eResidential Properties\u003c\/li\u003e\n\u003cli\u003eNew-Build Electrical Installations\u003c\/li\u003e\n\u003cli\u003eConsumer Unit Replacements\u003c\/li\u003e\n\u003cli\u003eConsumer Unit Upgrades\u003c\/li\u003e\n\u003cli\u003eCircuit Extensions\u003c\/li\u003e\n\u003cli\u003eIndividual Circuit Protection\u003c\/li\u003e\n\u003cli\u003eAppropriate Light Commercial Installations\u003c\/li\u003e\n\u003cli\u003eElectrical Distribution Upgrades\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose the FuseBox RTA063230B?\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTA063230B\u003c\/strong\u003e combines \u003cstrong\u003eoverload, short-circuit and 30mA residual current protection\u003c\/strong\u003e within a single compact protective device.\u003c\/p\u003e\n\u003cp\u003eIts combination of a \u003cstrong\u003e32A rating, B Curve characteristic, Type A residual protection and 6kA breaking capacity\u003c\/strong\u003e makes it a practical solution for appropriately designed circuits within FuseBox consumer units.\u003c\/p\u003e\n\u003cp\u003eThe compact \u003cstrong\u003esingle-module DIN rail design\u003c\/strong\u003e also helps maximise available space while allowing individual circuits to benefit from dedicated RCBO protection.\u003c\/p\u003e","brand":"FuseBox Consumer Units \u0026 Circuit Protection","offers":[{"title":"Default Title","offer_id":54694315065690,"sku":"RTA063230B","price":13.37,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/RTA_060630_B_fef9b50559_1c4e17f3-dfd9-46ef-ba4e-b0daa00fbf29.webp?v=1788437132"},{"product_id":"fusebox-40a-30ma-type-a-b-curve-6ka-rcbo-rta064030b","title":"FuseBox 40A 30mA Type A B Curve 6kA RCBO | RTA064030B","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eFuseBox 40A 30mA Type A B Curve 6kA RCBO | RTA064030B\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2\u003e40A Single Module Type A RCBO for FuseBox Consumer Units\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTA064030B\u003c\/strong\u003e is a \u003cstrong\u003e40A 30mA Type A B Curve RCBO\u003c\/strong\u003e designed to provide combined overcurrent and residual current protection for individual circuits within compatible FuseBox consumer units.\u003c\/p\u003e\n\u003cp\u003eCombining the functions of an \u003cstrong\u003eMCB and RCD within one compact device\u003c\/strong\u003e, the RTA064030B protects against \u003cstrong\u003eoverloads, short circuits and residual current \/ earth leakage faults\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eWith a \u003cstrong\u003e40A rated current, 30mA sensitivity, Type A residual current characteristics, B Curve tripping and 6kA breaking capacity\u003c\/strong\u003e, it provides comprehensive circuit protection while occupying just one module within the consumer unit. FuseBox lists the RTA064030B as the 40A model in its 6kA Type A RCBO range. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e40A Rated Current\u003c\/li\u003e\n\u003cli\u003e30mA Residual Operating Current\u003c\/li\u003e\n\u003cli\u003eType A Residual Current Protection\u003c\/li\u003e\n\u003cli\u003eB Curve Tripping Characteristic\u003c\/li\u003e\n\u003cli\u003e6kA Short-Circuit Breaking Capacity\u003c\/li\u003e\n\u003cli\u003eCombined RCD \u0026amp; MCB Protection\u003c\/li\u003e\n\u003cli\u003eProtects Against Overloads\u003c\/li\u003e\n\u003cli\u003eProtects Against Short Circuits\u003c\/li\u003e\n\u003cli\u003eProtects Against Earth Leakage Faults\u003c\/li\u003e\n\u003cli\u003eDetects AC \u0026amp; Pulsating DC Residual Currents\u003c\/li\u003e\n\u003cli\u003e1P + N Configuration\u003c\/li\u003e\n\u003cli\u003eCompact Single Module Design\u003c\/li\u003e\n\u003cli\u003e230V AC Rated Voltage\u003c\/li\u003e\n\u003cli\u003e50\/60Hz Operation\u003c\/li\u003e\n\u003cli\u003eIP20 Protection\u003c\/li\u003e\n\u003cli\u003e35mm DIN Rail Mounting\u003c\/li\u003e\n\u003cli\u003e450mm Flying Neutral Cable\u003c\/li\u003e\n\u003cli\u003e10,000 Mechanical Operations\u003c\/li\u003e\n\u003cli\u003eDesigned for FuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eManufactured to IEC\/EN 61009-1 \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCombined RCBO Circuit Protection\u003c\/h2\u003e\n\u003cp\u003eThe RTA064030B combines \u003cstrong\u003eresidual current and overcurrent protection within a single device\u003c\/strong\u003e, providing protection against three key electrical fault conditions:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOverloads\u003c\/li\u003e\n\u003cli\u003eShort Circuits\u003c\/li\u003e\n\u003cli\u003eResidual Current \/ Earth Leakage Faults\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUsing dedicated RCBOs on individual outgoing circuits can also improve circuit separation compared with arrangements where several circuits share one RCD. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eType A Residual Current Protection\u003c\/h2\u003e\n\u003cp\u003eThe RTA064030B provides \u003cstrong\u003eType A residual current protection\u003c\/strong\u003e, designed to respond to both AC and pulsating DC residual currents.\u003c\/p\u003e\n\u003cp\u003eFuseBox specifies the device's residual current characteristics as \u003cstrong\u003eType A for AC and pulsating DC up to 6mA\u003c\/strong\u003e, making it suitable for many modern electrical installations incorporating electronic loads. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e40A B Curve Protection\u003c\/h2\u003e\n\u003cp\u003eWith a rated current of \u003cstrong\u003e40A\u003c\/strong\u003e, the RTA064030B uses a \u003cstrong\u003eB Curve tripping characteristic of 3–5 In\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe 40A rating makes this model suitable for appropriately designed circuits requiring this level of overcurrent protection. Selection should always be based on the connected load, cable size, installation method and applicable electrical installation requirements.\u003c\/p\u003e\n\u003ch2\u003e6kA Short-Circuit Breaking Capacity\u003c\/h2\u003e\n\u003cp\u003eThe RTA064030B has a rated short-circuit breaking capacity of \u003cstrong\u003e6000A \/ 6kA\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis enables the RCBO to provide short-circuit protection within installations where a 6kA protective device is appropriate. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eCompact Single Module Design\u003c\/h2\u003e\n\u003cp\u003eDespite combining residual current and overcurrent protection, the RTA064030B occupies only \u003cstrong\u003eone module\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIts compact dimensions of approximately \u003cstrong\u003e114 x 17.8 x 69.6mm\u003c\/strong\u003e make efficient use of available consumer unit space, particularly where multiple circuits require individual RCBO protection. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe device mounts onto a standard \u003cstrong\u003e35mm DIN rail\u003c\/strong\u003e and incorporates a \u003cstrong\u003e450mm flying neutral cable\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eIndividual Circuit Protection\u003c\/h2\u003e\n\u003cp\u003eUsing RCBOs allows individual outgoing circuits to receive their own residual current and overcurrent protection.\u003c\/p\u003e\n\u003cp\u003eThis arrangement can help minimise disruption when a fault occurs because the affected circuit has its own dedicated protective device rather than multiple circuits relying upon a shared RCD.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e FuseBox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Code:\u003c\/strong\u003e RTA064030B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e RCBO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 40A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Residual Operating Current:\u003c\/strong\u003e 30mA \/ 0.03A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCD Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResidual Current Characteristics:\u003c\/strong\u003e AC \u0026amp; Pulsating DC up to 6mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristic:\u003c\/strong\u003e B Curve, 3–5 In\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Breaking Capacity:\u003c\/strong\u003e 6000A \/ 6kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 230V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Rating:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Modules:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e 35mm DIN Rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Incoming Terminal Capacity:\u003c\/strong\u003e 1–16mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Outgoing Terminal Capacity:\u003c\/strong\u003e 1–10mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncoming Recommended Tightening Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutgoing Recommended Tightening Torque:\u003c\/strong\u003e 1.2Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlying Neutral Cable Length:\u003c\/strong\u003e 450mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Endurance:\u003c\/strong\u003e 10,000 Operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e PA6 \/ Nylon 6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.2kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBi-Directional:\u003c\/strong\u003e No\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eDomestic Electrical Installations\u003c\/li\u003e\n\u003cli\u003eAppropriate 40A Final Circuits\u003c\/li\u003e\n\u003cli\u003eResidential Properties\u003c\/li\u003e\n\u003cli\u003eNew-Build Electrical Installations\u003c\/li\u003e\n\u003cli\u003eConsumer Unit Replacements\u003c\/li\u003e\n\u003cli\u003eConsumer Unit Upgrades\u003c\/li\u003e\n\u003cli\u003eIndividual Circuit Protection\u003c\/li\u003e\n\u003cli\u003eAppropriate Heating Loads\u003c\/li\u003e\n\u003cli\u003eAppropriate Light Commercial Installations\u003c\/li\u003e\n\u003cli\u003eElectrical Distribution Upgrades\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose the FuseBox RTA064030B?\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTA064030B\u003c\/strong\u003e combines \u003cstrong\u003eoverload, short-circuit and 30mA residual current protection\u003c\/strong\u003e within one compact protective device.\u003c\/p\u003e\n\u003cp\u003eIts combination of a \u003cstrong\u003e40A rating, B Curve characteristic, Type A residual protection and 6kA breaking capacity\u003c\/strong\u003e makes it a practical solution for appropriately designed circuits within FuseBox consumer units.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003esingle-module DIN rail design\u003c\/strong\u003e also makes efficient use of available consumer unit space while providing dedicated RCBO protection to the connected circuit.\u003c\/p\u003e","brand":"FuseBox Consumer Units \u0026 Circuit Protection","offers":[{"title":"Default Title","offer_id":54694319980890,"sku":"RTA064030B","price":13.37,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/RTA_060630_B_fef9b50559_1c4e17f3-dfd9-46ef-ba4e-b0daa00fbf29.webp?v=1788437132"},{"product_id":"fusebox-6a-30ma-type-a-b-curve-6ka-bi-directional-mini-rcbo-rtamb06bd","title":"FuseBox 6A 30mA Type A B Curve 6kA Bi-Directional Mini RCBO | RTAMB06BD","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eFuseBox 6A 30mA Type A B Curve 6kA Bi-Directional Mini RCBO | RTAMB06BD\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2\u003e6A Bi-Directional Type A Mini RCBO for FuseBox Consumer Units\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTAMB06BD\u003c\/strong\u003e is a compact \u003cstrong\u003e6A 30mA Type A bi-directional RCBO\u003c\/strong\u003e designed to provide combined overcurrent and residual current protection while allowing current to flow safely in either direction.\u003c\/p\u003e\n\u003cp\u003eFeaturing a \u003cstrong\u003eB Curve tripping characteristic, 6kA short-circuit capacity and 1P+N switched configuration\u003c\/strong\u003e, this mini RCBO protects against \u003cstrong\u003eoverloads, short circuits and earth leakage faults\u003c\/strong\u003e. Its bi-directional design makes it particularly suitable for modern electrical installations incorporating technologies such as \u003cstrong\u003esolar PV and other applications where current may flow in both directions\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eIts compact \u003cstrong\u003esingle-module format\u003c\/strong\u003e also helps maximise working space inside compatible FuseBox consumer units.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e6A Rated Current\u003c\/li\u003e\n\u003cli\u003e30mA Residual Operating Current\u003c\/li\u003e\n\u003cli\u003eType A Residual Current Protection\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBi-Directional Operation\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eB Curve Tripping Characteristic\u003c\/li\u003e\n\u003cli\u003e6kA Short-Circuit Breaking Capacity\u003c\/li\u003e\n\u003cli\u003eCombined RCD \u0026amp; MCB Protection\u003c\/li\u003e\n\u003cli\u003eProtects Against Overloads\u003c\/li\u003e\n\u003cli\u003eProtects Against Short Circuits\u003c\/li\u003e\n\u003cli\u003eProtects Against Earth Leakage Faults\u003c\/li\u003e\n\u003cli\u003eSuitable Where Current Can Flow in Either Direction\u003c\/li\u003e\n\u003cli\u003eIdeal for Appropriate Solar PV Applications\u003c\/li\u003e\n\u003cli\u003e1P + N Switched Configuration\u003c\/li\u003e\n\u003cli\u003eLine \u0026amp; Neutral Switched\u003c\/li\u003e\n\u003cli\u003eCompact Mini RCBO Design\u003c\/li\u003e\n\u003cli\u003eSingle Module Width\u003c\/li\u003e\n\u003cli\u003e230V AC\u003c\/li\u003e\n\u003cli\u003e50\/60Hz\u003c\/li\u003e\n\u003cli\u003eIP20\u003c\/li\u003e\n\u003cli\u003e35mm DIN Rail Mounting\u003c\/li\u003e\n\u003cli\u003eFlying Neutral Cable\u003c\/li\u003e\n\u003cli\u003eSuitable for FuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eIEC 61009-1 \u0026amp; IEC 61009-2-2 Compliant \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBi-Directional Protection for Modern Installations\u003c\/h2\u003e\n\u003cp\u003eOne of the key advantages of the \u003cstrong\u003eRTAMB06BD\u003c\/strong\u003e is its \u003cstrong\u003ebi-directional design\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eUnlike a protective device intended for only one direction of power flow, a bi-directional RCBO can accommodate current flowing in either direction. This makes it particularly relevant to modern installations incorporating \u003cstrong\u003esolar PV generation\u003c\/strong\u003e and other systems where power flow may not always be exclusively from the supply towards the load. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eCombined RCBO Circuit Protection\u003c\/h2\u003e\n\u003cp\u003eThe RTAMB06BD combines the functions of an \u003cstrong\u003eMCB and RCD within one compact device\u003c\/strong\u003e, providing protection against:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOverloads\u003c\/li\u003e\n\u003cli\u003eShort Circuits\u003c\/li\u003e\n\u003cli\u003eResidual Current \/ Earth Leakage Faults\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIndividual RCBO protection also helps improve circuit separation, allowing the affected circuit to have its own dedicated residual current and overcurrent protection.\u003c\/p\u003e\n\u003ch2\u003eType A 30mA Residual Current Protection\u003c\/h2\u003e\n\u003cp\u003eThe RTAMB06BD provides \u003cstrong\u003eType A residual current protection\u003c\/strong\u003e with a rated residual operating current of \u003cstrong\u003e30mA\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eType A devices are designed to respond to AC and pulsating DC residual currents, making them particularly relevant to modern electrical installations incorporating electronic equipment. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e6A B Curve Protection\u003c\/h2\u003e\n\u003cp\u003eThis model has a rated current of \u003cstrong\u003e6A\u003c\/strong\u003e and uses a \u003cstrong\u003eB Curve tripping characteristic\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe B Curve characteristic is specified at \u003cstrong\u003e3–5 In\u003c\/strong\u003e, with the 6A rating making the device suitable for appropriately designed lower-current circuits where this level of overcurrent protection is required. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eCorrect protective device selection should always consider the connected load, cable size, installation method and applicable wiring requirements.\u003c\/p\u003e\n\u003ch2\u003e6kA Short-Circuit Capacity\u003c\/h2\u003e\n\u003cp\u003eThe FuseBox RTAMB06BD has a rated short-circuit breaking capacity of \u003cstrong\u003e6000A \/ 6kA\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis enables the RCBO to provide short-circuit protection in installations where a 6kA rated protective device is appropriate. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e1P+N Switched Mini Design\u003c\/h2\u003e\n\u003cp\u003eThe RTAMB06BD features a \u003cstrong\u003e1P+N switched configuration\u003c\/strong\u003e, meaning both the line and neutral are switched.\u003c\/p\u003e\n\u003cp\u003eDespite providing combined RCBO protection and switched-neutral functionality, the device occupies just \u003cstrong\u003eone module\u003c\/strong\u003e, measuring approximately \u003cstrong\u003e18mm wide\u003c\/strong\u003e. Its compact construction helps increase available working space inside a FuseBox consumer unit. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e FuseBox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Code:\u003c\/strong\u003e RTAMB06BD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Bi-Directional Mini RCBO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 6A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Residual Operating Current:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCD Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperation:\u003c\/strong\u003e Bi-Directional\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristic:\u003c\/strong\u003e B Curve, 3–5 In\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Breaking Capacity:\u003c\/strong\u003e 6000A \/ 6kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 1P + N Switched\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 230V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Rating:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Modules:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e 35mm DIN Rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Incoming Terminal Capacity:\u003c\/strong\u003e 16mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Outgoing Terminal Capacity:\u003c\/strong\u003e 10mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncoming Recommended Tightening Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutgoing Recommended Tightening Torque:\u003c\/strong\u003e 1.2Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNeutral Cable CSA:\u003c\/strong\u003e 2.5mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Endurance:\u003c\/strong\u003e 10,000 Operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e PA6 \/ Nylon 6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e 85 x 18 x 69.5mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Approx. 0.144kg\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eDomestic Electrical Installations\u003c\/li\u003e\n\u003cli\u003eSolar PV Installations\u003c\/li\u003e\n\u003cli\u003eApplications with Bi-Directional Current Flow\u003c\/li\u003e\n\u003cli\u003eAppropriate Renewable Energy Installations\u003c\/li\u003e\n\u003cli\u003eResidential Properties\u003c\/li\u003e\n\u003cli\u003eNew-Build Electrical Installations\u003c\/li\u003e\n\u003cli\u003eConsumer Unit Upgrades\u003c\/li\u003e\n\u003cli\u003eAppropriate 6A Final Circuits\u003c\/li\u003e\n\u003cli\u003eIndividual Circuit Protection\u003c\/li\u003e\n\u003cli\u003eAppropriate Light Commercial Installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose the FuseBox RTAMB06BD?\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTAMB06BD\u003c\/strong\u003e combines compact dimensions with \u003cstrong\u003e6A overcurrent protection, 30mA Type A residual current protection and bi-directional operation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIts bi-directional capability makes it particularly useful for modern installations such as \u003cstrong\u003esolar PV systems\u003c\/strong\u003e, where current can flow in either direction. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWith a \u003cstrong\u003eB Curve characteristic, 6kA breaking capacity, switched line and neutral and single-module format\u003c\/strong\u003e, the RTAMB06BD provides a versatile circuit protection solution while making efficient use of available space within the consumer unit.\u003c\/p\u003e","brand":"FuseBox Consumer Units \u0026 Circuit Protection","offers":[{"title":"Default Title","offer_id":54694334005594,"sku":"RTAMB06BD","price":20.02,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/RTAMB_06_BD_ANGLE_7cb2d2b5c6.webp?v=1788437852"},{"product_id":"fusebox-10a-30ma-type-a-b-curve-6ka-bi-directional-mini-rcbo-rtamb10bd","title":"FuseBox 10A 30mA Type A B Curve 6kA Bi-Directional Mini RCBO | RTAMB10BD","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eFuseBox 10A 30mA Type A B Curve 6kA Bi-Directional Mini RCBO | RTAMB10BD\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2\u003e10A Bi-Directional Type A Mini RCBO for FuseBox Consumer Units\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTAMB10BD\u003c\/strong\u003e is a compact \u003cstrong\u003e10A 30mA Type A bi-directional mini RCBO\u003c\/strong\u003e designed to provide combined residual current and overcurrent protection for individual circuits within compatible FuseBox consumer units.\u003c\/p\u003e\n\u003cp\u003eFeaturing a \u003cstrong\u003eB Curve tripping characteristic, 6kA short-circuit breaking capacity and 1P+N switched configuration\u003c\/strong\u003e, the RTAMB10BD protects against \u003cstrong\u003eoverloads, short circuits and residual current \/ earth leakage faults\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIts \u003cstrong\u003ebi-directional design\u003c\/strong\u003e allows the device to operate where current may flow in either direction, making it particularly relevant to modern electrical installations, including appropriate \u003cstrong\u003esolar PV and renewable energy applications\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e10A Rated Current\u003c\/li\u003e\n\u003cli\u003e30mA Residual Operating Current\u003c\/li\u003e\n\u003cli\u003eType A Residual Current Protection\u003c\/li\u003e\n\u003cli\u003eBi-Directional Operation\u003c\/li\u003e\n\u003cli\u003eB Curve Tripping Characteristic\u003c\/li\u003e\n\u003cli\u003e6kA Short-Circuit Breaking Capacity\u003c\/li\u003e\n\u003cli\u003eCombined RCD \u0026amp; MCB Protection\u003c\/li\u003e\n\u003cli\u003eProtects Against Overloads\u003c\/li\u003e\n\u003cli\u003eProtects Against Short Circuits\u003c\/li\u003e\n\u003cli\u003eProtects Against Earth Leakage Faults\u003c\/li\u003e\n\u003cli\u003eDetects AC \u0026amp; Pulsating DC Residual Currents\u003c\/li\u003e\n\u003cli\u003eSuitable Where Current May Flow in Either Direction\u003c\/li\u003e\n\u003cli\u003eSuitable for Appropriate Solar PV Applications\u003c\/li\u003e\n\u003cli\u003e1P + N Switched Configuration\u003c\/li\u003e\n\u003cli\u003eLine \u0026amp; Neutral Switched\u003c\/li\u003e\n\u003cli\u003eCompact Mini RCBO Design\u003c\/li\u003e\n\u003cli\u003eSingle Module Width\u003c\/li\u003e\n\u003cli\u003e230V AC Rated Voltage\u003c\/li\u003e\n\u003cli\u003e50\/60Hz Operation\u003c\/li\u003e\n\u003cli\u003eIP20 Protection\u003c\/li\u003e\n\u003cli\u003e35mm DIN Rail Mounting\u003c\/li\u003e\n\u003cli\u003eDesigned for Compatible FuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eIEC 61009-1 \u0026amp; IEC 61009-2-2 Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBi-Directional Circuit Protection\u003c\/h2\u003e\n\u003cp\u003eA key feature of the \u003cstrong\u003eFuseBox RTAMB10BD\u003c\/strong\u003e is its \u003cstrong\u003ebi-directional operation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eBi-directional protective devices are designed for installations where electrical current may flow in either direction. This is increasingly important in electrical systems incorporating generation technologies such as \u003cstrong\u003esolar PV\u003c\/strong\u003e, where electricity can be supplied back through parts of the installation.\u003c\/p\u003e\n\u003cp\u003eThe RTAMB10BD therefore provides a modern circuit protection option for appropriately designed installations requiring a \u003cstrong\u003e10A bi-directional RCBO\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eCombined RCBO Protection\u003c\/h2\u003e\n\u003cp\u003eThe RTAMB10BD combines the functionality of an \u003cstrong\u003eMCB and RCD within one device\u003c\/strong\u003e, providing protection against:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOverloads\u003c\/li\u003e\n\u003cli\u003eShort Circuits\u003c\/li\u003e\n\u003cli\u003eResidual Current \/ Earth Leakage Faults\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProviding each outgoing circuit with dedicated RCBO protection can also improve circuit separation compared with arrangements where several circuits share a single RCD.\u003c\/p\u003e\n\u003ch2\u003e30mA Type A Residual Current Protection\u003c\/h2\u003e\n\u003cp\u003eThe RTAMB10BD provides \u003cstrong\u003e30mA Type A residual current protection\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eType A RCBOs are designed to detect both \u003cstrong\u003esinusoidal AC and pulsating DC residual currents\u003c\/strong\u003e, making them particularly relevant to modern installations incorporating electronic equipment.\u003c\/p\u003e\n\u003cp\u003eThe 30mA residual operating current provides additional protection for appropriately designed final circuits.\u003c\/p\u003e\n\u003ch2\u003e10A B Curve Protection\u003c\/h2\u003e\n\u003cp\u003eThis model has a rated current of \u003cstrong\u003e10A\u003c\/strong\u003e and uses a \u003cstrong\u003eB Curve tripping characteristic\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe 10A rating makes it suitable for appropriately designed circuits requiring this level of overcurrent protection, while the B Curve characteristic is commonly used for circuits with relatively low inrush currents.\u003c\/p\u003e\n\u003cp\u003eCorrect protective device selection should always take account of the circuit load, cable size, installation method and applicable wiring requirements.\u003c\/p\u003e\n\u003ch2\u003e6kA Short-Circuit Breaking Capacity\u003c\/h2\u003e\n\u003cp\u003eThe FuseBox RTAMB10BD has a rated short-circuit breaking capacity of \u003cstrong\u003e6000A \/ 6kA\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis allows the RCBO to provide short-circuit protection within electrical installations where a 6kA rated protective device is appropriate.\u003c\/p\u003e\n\u003ch2\u003eCompact 1P+N Switched Design\u003c\/h2\u003e\n\u003cp\u003eThe RTAMB10BD uses a compact \u003cstrong\u003e1P+N switched configuration\u003c\/strong\u003e, providing switching of both the line and neutral.\u003c\/p\u003e\n\u003cp\u003eDespite combining overcurrent protection, residual current protection and switched-neutral functionality, the device occupies just \u003cstrong\u003eone module\u003c\/strong\u003e within the consumer unit.\u003c\/p\u003e\n\u003cp\u003eIts compact mini RCBO construction helps maximise available wiring and working space, particularly where multiple circuits require individual RCBO protection.\u003c\/p\u003e\n\u003ch2\u003eIdeal for Modern \u0026amp; Renewable Energy Installations\u003c\/h2\u003e\n\u003cp\u003eElectrical installations are increasingly incorporating technologies that can change the traditional direction of power flow.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003ebi-directional design\u003c\/strong\u003e of the RTAMB10BD makes it particularly useful for appropriately designed systems involving renewable generation or other applications where power may flow in either direction through the protective device.\u003c\/p\u003e\n\u003cp\u003eThis makes the FuseBox RTAMB range a versatile option when designing modern consumer unit installations.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e FuseBox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Code:\u003c\/strong\u003e RTAMB10BD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Bi-Directional Mini RCBO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 10A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Residual Operating Current:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCD Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperation:\u003c\/strong\u003e Bi-Directional\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristic:\u003c\/strong\u003e B Curve, 3–5 In\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Breaking Capacity:\u003c\/strong\u003e 6000A \/ 6kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 1P + N Switched\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine \u0026amp; Neutral Switching:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 230V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Rating:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Modules:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e 35mm DIN Rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Incoming Terminal Capacity:\u003c\/strong\u003e 16mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Outgoing Terminal Capacity:\u003c\/strong\u003e 10mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncoming Recommended Tightening Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutgoing Recommended Tightening Torque:\u003c\/strong\u003e 1.2Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNeutral Cable CSA:\u003c\/strong\u003e 2.5mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Endurance:\u003c\/strong\u003e 10,000 Operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e PA6 \/ Nylon 6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e Approx. 85 x 18 x 69.5mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e IEC 61009-1, IEC 61009-2-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eDomestic Electrical Installations\u003c\/li\u003e\n\u003cli\u003eAppropriate 10A Final Circuits\u003c\/li\u003e\n\u003cli\u003eSolar PV Installations\u003c\/li\u003e\n\u003cli\u003eRenewable Energy Systems\u003c\/li\u003e\n\u003cli\u003eApplications with Bi-Directional Current Flow\u003c\/li\u003e\n\u003cli\u003eResidential Properties\u003c\/li\u003e\n\u003cli\u003eNew-Build Electrical Installations\u003c\/li\u003e\n\u003cli\u003eConsumer Unit Upgrades\u003c\/li\u003e\n\u003cli\u003eIndividual Circuit Protection\u003c\/li\u003e\n\u003cli\u003eAppropriate Light Commercial Installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose the FuseBox RTAMB10BD?\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTAMB10BD\u003c\/strong\u003e combines \u003cstrong\u003e10A overcurrent protection, 30mA Type A residual current protection and bi-directional capability\u003c\/strong\u003e within a compact single-module device.\u003c\/p\u003e\n\u003cp\u003eIts \u003cstrong\u003ebi-directional design\u003c\/strong\u003e makes it particularly relevant to modern electrical installations where power can flow in either direction, including appropriate solar PV and renewable energy applications.\u003c\/p\u003e\n\u003cp\u003eWith a \u003cstrong\u003eB Curve characteristic, 6kA breaking capacity and 1P+N switched configuration\u003c\/strong\u003e, the RTAMB10BD provides comprehensive individual circuit protection while making efficient use of available consumer unit space.\u003c\/p\u003e","brand":"FuseBox Consumer Units \u0026 Circuit Protection","offers":[{"title":"Default Title","offer_id":54694349373786,"sku":"RTAMB10BD","price":20.02,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/RTAMB_10_BD_ANGLE_243e6d9d95.webp?v=1788437980"},{"product_id":"fusebox-16a-30ma-type-a-b-curve-6ka-bi-directional-mini-rcbo-rtamb16bd","title":"FuseBox 16A 30mA Type A B Curve 6kA Bi-Directional Mini RCBO | RTAMB16BD","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eFuseBox 16A 30mA Type A B Curve 6kA Bi-Directional Mini RCBO | RTAMB16BD\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2\u003e16A Bi-Directional Type A Mini RCBO for FuseBox Consumer Units\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTAMB16BD\u003c\/strong\u003e is a compact \u003cstrong\u003e16A 30mA Type A bi-directional mini RCBO\u003c\/strong\u003e designed to provide combined residual current and overcurrent protection for individual circuits within compatible FuseBox consumer units.\u003c\/p\u003e\n\u003cp\u003eCombining the functions of an \u003cstrong\u003eMCB and RCD in a single protective device\u003c\/strong\u003e, the RTAMB16BD provides protection against \u003cstrong\u003eoverloads, short circuits and residual current \/ earth leakage faults\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIts \u003cstrong\u003ebi-directional design\u003c\/strong\u003e allows current to flow safely through the device in either direction, making it particularly relevant to modern electrical installations, including appropriately designed \u003cstrong\u003esolar PV, renewable energy and other installations with bi-directional power flow\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e16A Rated Current\u003c\/li\u003e\n\u003cli\u003e30mA Residual Operating Current\u003c\/li\u003e\n\u003cli\u003eType A Residual Current Protection\u003c\/li\u003e\n\u003cli\u003eBi-Directional Operation\u003c\/li\u003e\n\u003cli\u003eB Curve Tripping Characteristic\u003c\/li\u003e\n\u003cli\u003e6kA Short-Circuit Breaking Capacity\u003c\/li\u003e\n\u003cli\u003eCombined RCD \u0026amp; MCB Protection\u003c\/li\u003e\n\u003cli\u003eProtects Against Overloads\u003c\/li\u003e\n\u003cli\u003eProtects Against Short Circuits\u003c\/li\u003e\n\u003cli\u003eProtects Against Earth Leakage Faults\u003c\/li\u003e\n\u003cli\u003eDetects AC \u0026amp; Pulsating DC Residual Currents\u003c\/li\u003e\n\u003cli\u003eSuitable Where Current May Flow in Either Direction\u003c\/li\u003e\n\u003cli\u003eSuitable for Appropriate Solar PV Applications\u003c\/li\u003e\n\u003cli\u003e1P + N Switched Configuration\u003c\/li\u003e\n\u003cli\u003eLine \u0026amp; Neutral Switching\u003c\/li\u003e\n\u003cli\u003eCompact Mini RCBO Design\u003c\/li\u003e\n\u003cli\u003eSingle Module Width\u003c\/li\u003e\n\u003cli\u003e230V AC Rated Voltage\u003c\/li\u003e\n\u003cli\u003e50\/60Hz Operation\u003c\/li\u003e\n\u003cli\u003eIP20 Protection\u003c\/li\u003e\n\u003cli\u003e35mm DIN Rail Mounting\u003c\/li\u003e\n\u003cli\u003eDesigned for Compatible FuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eIEC 61009-1 \u0026amp; IEC 61009-2-2 Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBi-Directional Protection for Modern Installations\u003c\/h2\u003e\n\u003cp\u003eA key feature of the \u003cstrong\u003eFuseBox RTAMB16BD\u003c\/strong\u003e is its \u003cstrong\u003ebi-directional operation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eTraditional electrical installations primarily distribute electricity in one direction, from the supply towards the connected loads. Modern installations incorporating technologies such as \u003cstrong\u003esolar PV generation\u003c\/strong\u003e can involve power flowing in different directions.\u003c\/p\u003e\n\u003cp\u003eA bi-directional RCBO is designed to accommodate this type of power flow, making the RTAMB16BD a versatile option for appropriately designed modern electrical installations.\u003c\/p\u003e\n\u003ch2\u003eCombined RCBO Circuit Protection\u003c\/h2\u003e\n\u003cp\u003eThe RTAMB16BD combines \u003cstrong\u003eresidual current and overcurrent protection\u003c\/strong\u003e within a single compact device.\u003c\/p\u003e\n\u003cp\u003eThis allows it to provide protection against:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOverloads\u003c\/li\u003e\n\u003cli\u003eShort Circuits\u003c\/li\u003e\n\u003cli\u003eResidual Current \/ Earth Leakage Faults\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUsing individual RCBOs can also improve circuit separation by providing dedicated residual current and overcurrent protection to each appropriately designed outgoing circuit.\u003c\/p\u003e\n\u003ch2\u003e30mA Type A Residual Current Protection\u003c\/h2\u003e\n\u003cp\u003eThe RTAMB16BD provides \u003cstrong\u003e30mA Type A residual current protection\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eType A devices are designed to respond to both \u003cstrong\u003esinusoidal AC and pulsating DC residual currents\u003c\/strong\u003e, making them particularly relevant to contemporary electrical installations containing electronic equipment.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e30mA residual operating current\u003c\/strong\u003e provides additional residual current protection for appropriately designed final circuits.\u003c\/p\u003e\n\u003ch2\u003e16A B Curve Protection\u003c\/h2\u003e\n\u003cp\u003eThe RTAMB16BD has a rated current of \u003cstrong\u003e16A\u003c\/strong\u003e and features a \u003cstrong\u003eB Curve tripping characteristic\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIts 16A rating makes the RCBO suitable for appropriately designed circuits requiring this level of overcurrent protection.\u003c\/p\u003e\n\u003cp\u003eThe correct protective device should always be selected according to factors including connected load, conductor size, installation method and applicable wiring requirements.\u003c\/p\u003e\n\u003ch2\u003e6kA Short-Circuit Breaking Capacity\u003c\/h2\u003e\n\u003cp\u003eThe FuseBox RTAMB16BD features a \u003cstrong\u003e6000A \/ 6kA short-circuit breaking capacity\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis enables the device to provide short-circuit protection in electrical installations where a 6kA rated protective device is appropriate.\u003c\/p\u003e\n\u003ch2\u003eCompact 1P+N Switched Design\u003c\/h2\u003e\n\u003cp\u003eThe RTAMB16BD features a \u003cstrong\u003e1P + N switched configuration\u003c\/strong\u003e, providing switching of both line and neutral.\u003c\/p\u003e\n\u003cp\u003eDespite incorporating residual current protection, overcurrent protection and switched-neutral functionality, its compact mini design occupies just \u003cstrong\u003eone module\u003c\/strong\u003e within the consumer unit.\u003c\/p\u003e\n\u003cp\u003eThis helps maximise available wiring and working space, particularly where several circuits require individual RCBO protection.\u003c\/p\u003e\n\u003ch2\u003eIdeal for Solar PV \u0026amp; Renewable Energy Applications\u003c\/h2\u003e\n\u003cp\u003eThe growth of solar PV and other renewable energy technologies has increased the requirement for electrical equipment capable of accommodating different directions of power flow.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003ebi-directional capability\u003c\/strong\u003e of the RTAMB16BD makes it suitable for appropriately designed renewable energy installations where this functionality is required.\u003c\/p\u003e\n\u003cp\u003eIts compact format also makes it a practical option when upgrading or designing FuseBox consumer units for modern electrical systems.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e FuseBox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Code:\u003c\/strong\u003e RTAMB16BD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Bi-Directional Mini RCBO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Residual Operating Current:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCD Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperation:\u003c\/strong\u003e Bi-Directional\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristic:\u003c\/strong\u003e B Curve, 3–5 In\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Breaking Capacity:\u003c\/strong\u003e 6000A \/ 6kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 1P + N Switched\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine \u0026amp; Neutral Switching:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 230V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Rating:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Modules:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e 35mm DIN Rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Incoming Terminal Capacity:\u003c\/strong\u003e 16mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Outgoing Terminal Capacity:\u003c\/strong\u003e 10mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncoming Recommended Tightening Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutgoing Recommended Tightening Torque:\u003c\/strong\u003e 1.2Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNeutral Cable CSA:\u003c\/strong\u003e 2.5mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Endurance:\u003c\/strong\u003e 10,000 Operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e PA6 \/ Nylon 6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e Approx. 85 x 18 x 69.5mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e IEC 61009-1, IEC 61009-2-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eDomestic Electrical Installations\u003c\/li\u003e\n\u003cli\u003eAppropriate 16A Final Circuits\u003c\/li\u003e\n\u003cli\u003eSolar PV Installations\u003c\/li\u003e\n\u003cli\u003eRenewable Energy Systems\u003c\/li\u003e\n\u003cli\u003eApplications with Bi-Directional Current Flow\u003c\/li\u003e\n\u003cli\u003eResidential Properties\u003c\/li\u003e\n\u003cli\u003eNew-Build Electrical Installations\u003c\/li\u003e\n\u003cli\u003eConsumer Unit Upgrades\u003c\/li\u003e\n\u003cli\u003eIndividual Circuit Protection\u003c\/li\u003e\n\u003cli\u003eAppropriate Light Commercial Installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose the FuseBox RTAMB16BD?\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTAMB16BD\u003c\/strong\u003e combines \u003cstrong\u003e16A overcurrent protection, 30mA Type A residual current protection and bi-directional capability\u003c\/strong\u003e within one compact protective device.\u003c\/p\u003e\n\u003cp\u003eIts bi-directional operation makes it particularly relevant to modern electrical installations where power may flow in either direction, including appropriately designed \u003cstrong\u003esolar PV and renewable energy systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eWith a \u003cstrong\u003eB Curve characteristic, 6kA breaking capacity and 1P+N switched configuration\u003c\/strong\u003e, the RTAMB16BD provides comprehensive individual circuit protection while making efficient use of available space inside a FuseBox consumer unit.\u003c\/p\u003e","brand":"FuseBox Consumer Units \u0026 Circuit Protection","offers":[{"title":"Default Title","offer_id":54694357434714,"sku":"RTAMB16BD","price":20.02,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/RTAMB_16_BD_ANGLE_1d73d69c9e.webp?v=1788438124"},{"product_id":"fusebox-20a-30ma-type-a-b-curve-6ka-bi-directional-mini-rcbo-rtamb20bd","title":"FuseBox 20A 30mA Type A B Curve 6kA Bi-Directional Mini RCBO | RTAMB20BD","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eFuseBox 20A 30mA Type A B Curve 6kA Bi-Directional Mini RCBO | RTAMB20BD\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2\u003e20A Bi-Directional Type A Mini RCBO for FuseBox Consumer Units\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTAMB20BD\u003c\/strong\u003e is a compact \u003cstrong\u003e20A 30mA Type A bi-directional mini RCBO\u003c\/strong\u003e designed to provide combined overcurrent and residual current protection for individual circuits within compatible FuseBox consumer units.\u003c\/p\u003e\n\u003cp\u003eCombining the functions of an \u003cstrong\u003eMCB and RCD in one device\u003c\/strong\u003e, the RTAMB20BD protects against \u003cstrong\u003eoverloads, short circuits and residual current \/ earth leakage faults\u003c\/strong\u003e while occupying just a single module.\u003c\/p\u003e\n\u003cp\u003eIts \u003cstrong\u003ebi-directional operation\u003c\/strong\u003e makes it particularly relevant to modern electrical installations where current may flow in either direction, including appropriately designed \u003cstrong\u003esolar PV, renewable energy and other power-generation applications\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e20A Rated Current\u003c\/li\u003e\n\u003cli\u003e30mA Residual Operating Current\u003c\/li\u003e\n\u003cli\u003eType A Residual Current Protection\u003c\/li\u003e\n\u003cli\u003eBi-Directional Operation\u003c\/li\u003e\n\u003cli\u003eB Curve Tripping Characteristic\u003c\/li\u003e\n\u003cli\u003e6kA Short-Circuit Breaking Capacity\u003c\/li\u003e\n\u003cli\u003eCombined RCD \u0026amp; MCB Protection\u003c\/li\u003e\n\u003cli\u003eProtects Against Overloads\u003c\/li\u003e\n\u003cli\u003eProtects Against Short Circuits\u003c\/li\u003e\n\u003cli\u003eProtects Against Earth Leakage Faults\u003c\/li\u003e\n\u003cli\u003eDetects AC \u0026amp; Pulsating DC Residual Currents\u003c\/li\u003e\n\u003cli\u003eSuitable Where Current May Flow in Either Direction\u003c\/li\u003e\n\u003cli\u003eSuitable for Appropriate Solar PV Applications\u003c\/li\u003e\n\u003cli\u003e1P + N Switched Configuration\u003c\/li\u003e\n\u003cli\u003eLine \u0026amp; Neutral Switching\u003c\/li\u003e\n\u003cli\u003eCompact Mini RCBO Design\u003c\/li\u003e\n\u003cli\u003eSingle Module Width\u003c\/li\u003e\n\u003cli\u003e230V AC Rated Voltage\u003c\/li\u003e\n\u003cli\u003e50\/60Hz Operation\u003c\/li\u003e\n\u003cli\u003eIP20 Protection\u003c\/li\u003e\n\u003cli\u003e35mm DIN Rail Mounting\u003c\/li\u003e\n\u003cli\u003eDesigned for Compatible FuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eIEC 61009-1 \u0026amp; IEC 61009-2-2 Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBi-Directional Protection for Modern Installations\u003c\/h2\u003e\n\u003cp\u003eA key advantage of the \u003cstrong\u003eFuseBox RTAMB20BD\u003c\/strong\u003e is its \u003cstrong\u003ebi-directional design\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eBi-directional protective devices are designed for applications where electrical current may flow through the device in either direction. This is increasingly relevant in installations incorporating technologies such as \u003cstrong\u003esolar PV generation\u003c\/strong\u003e, where power flow may differ from that of a conventional load-only circuit.\u003c\/p\u003e\n\u003cp\u003eThis makes the RTAMB20BD a practical circuit protection option for appropriately designed modern and renewable energy installations.\u003c\/p\u003e\n\u003ch2\u003eCombined RCBO Circuit Protection\u003c\/h2\u003e\n\u003cp\u003eThe RTAMB20BD combines \u003cstrong\u003eresidual current and overcurrent protection\u003c\/strong\u003e within a single protective device.\u003c\/p\u003e\n\u003cp\u003eIt provides protection against:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOverloads\u003c\/li\u003e\n\u003cli\u003eShort Circuits\u003c\/li\u003e\n\u003cli\u003eResidual Current \/ Earth Leakage Faults\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUsing dedicated RCBOs on individual outgoing circuits can also improve circuit separation by providing each circuit with its own residual current and overcurrent protection.\u003c\/p\u003e\n\u003ch2\u003e30mA Type A Residual Current Protection\u003c\/h2\u003e\n\u003cp\u003eThe RTAMB20BD provides \u003cstrong\u003e30mA Type A residual current protection\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eType A RCBOs are designed to respond to \u003cstrong\u003esinusoidal AC and pulsating DC residual currents\u003c\/strong\u003e, making them well suited to many modern electrical installations containing electronic equipment.\u003c\/p\u003e\n\u003cp\u003eThe 30mA rated residual operating current provides additional protection for appropriately designed final circuits.\u003c\/p\u003e\n\u003ch2\u003e20A B Curve Protection\u003c\/h2\u003e\n\u003cp\u003eWith a rated current of \u003cstrong\u003e20A\u003c\/strong\u003e, the RTAMB20BD features a \u003cstrong\u003eB Curve tripping characteristic\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe 20A rating makes this RCBO suitable for appropriately designed circuits requiring this level of overcurrent protection.\u003c\/p\u003e\n\u003cp\u003eProtective device selection should always consider factors including the connected load, cable size, installation method and applicable electrical installation requirements.\u003c\/p\u003e\n\u003ch2\u003e6kA Short-Circuit Breaking Capacity\u003c\/h2\u003e\n\u003cp\u003eThe FuseBox RTAMB20BD provides a rated short-circuit breaking capacity of \u003cstrong\u003e6000A \/ 6kA\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis allows the device to provide short-circuit protection within electrical installations where a 6kA rated protective device is appropriate.\u003c\/p\u003e\n\u003ch2\u003eCompact 1P+N Switched Design\u003c\/h2\u003e\n\u003cp\u003eThe RTAMB20BD features a \u003cstrong\u003e1P + N switched configuration\u003c\/strong\u003e, providing switching of both line and neutral.\u003c\/p\u003e\n\u003cp\u003eDespite incorporating residual current protection, overcurrent protection and switched-neutral functionality, its compact mini design occupies only \u003cstrong\u003eone module\u003c\/strong\u003e within the consumer unit.\u003c\/p\u003e\n\u003cp\u003eThis space-saving format helps maximise available wiring and working room, particularly in consumer units containing multiple individually protected circuits.\u003c\/p\u003e\n\u003ch2\u003eSuitable for Solar PV \u0026amp; Renewable Energy Installations\u003c\/h2\u003e\n\u003cp\u003eAs solar PV and other distributed energy technologies become increasingly common, electrical installations may need to accommodate power flowing in more than one direction.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003ebi-directional capability\u003c\/strong\u003e of the RTAMB20BD makes it suitable for appropriately designed installations where this functionality is required, including relevant \u003cstrong\u003esolar PV and renewable energy applications\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e FuseBox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Code:\u003c\/strong\u003e RTAMB20BD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Bi-Directional Mini RCBO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 20A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Residual Operating Current:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCD Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperation:\u003c\/strong\u003e Bi-Directional\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristic:\u003c\/strong\u003e B Curve, 3–5 In\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Breaking Capacity:\u003c\/strong\u003e 6000A \/ 6kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 1P + N Switched\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine \u0026amp; Neutral Switching:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 230V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Rating:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Modules:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e 35mm DIN Rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Incoming Terminal Capacity:\u003c\/strong\u003e 16mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Outgoing Terminal Capacity:\u003c\/strong\u003e 10mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncoming Recommended Tightening Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutgoing Recommended Tightening Torque:\u003c\/strong\u003e 1.2Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNeutral Cable CSA:\u003c\/strong\u003e 2.5mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Endurance:\u003c\/strong\u003e 10,000 Operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e PA6 \/ Nylon 6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e Approx. 85 x 18 x 69.5mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e IEC 61009-1, IEC 61009-2-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eDomestic Electrical Installations\u003c\/li\u003e\n\u003cli\u003eAppropriate 20A Final Circuits\u003c\/li\u003e\n\u003cli\u003eSolar PV Installations\u003c\/li\u003e\n\u003cli\u003eRenewable Energy Systems\u003c\/li\u003e\n\u003cli\u003eApplications with Bi-Directional Current Flow\u003c\/li\u003e\n\u003cli\u003eResidential Properties\u003c\/li\u003e\n\u003cli\u003eNew-Build Electrical Installations\u003c\/li\u003e\n\u003cli\u003eConsumer Unit Upgrades\u003c\/li\u003e\n\u003cli\u003eIndividual Circuit Protection\u003c\/li\u003e\n\u003cli\u003eAppropriate Light Commercial Installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose the FuseBox RTAMB20BD?\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTAMB20BD\u003c\/strong\u003e combines \u003cstrong\u003e20A overcurrent protection, 30mA Type A residual current protection and bi-directional operation\u003c\/strong\u003e within a compact single-module device.\u003c\/p\u003e\n\u003cp\u003eIts bi-directional capability makes it particularly relevant to modern installations where power may flow in either direction, including appropriately designed \u003cstrong\u003esolar PV and renewable energy systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eWith a \u003cstrong\u003eB Curve characteristic, 6kA breaking capacity and 1P+N switched configuration\u003c\/strong\u003e, the RTAMB20BD provides comprehensive individual circuit protection while making efficient use of valuable consumer unit space.\u003c\/p\u003e","brand":"FuseBox Consumer Units \u0026 Circuit Protection","offers":[{"title":"Default Title","offer_id":54694364643674,"sku":"RTAMB20BD","price":20.02,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/RTAMB_20_BD_ANGLE_e93fe09029.webp?v=1788438224"},{"product_id":"fusebox-32a-30ma-type-a-b-curve-6ka-bi-directional-mini-rcbo-rtamb32bd","title":"FuseBox 32A 30mA Type A B Curve 6kA Bi-Directional Mini RCBO | RTAMB32BD","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eFuseBox 32A 30mA Type A B Curve 6kA Bi-Directional Mini RCBO | RTAMB32BD\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2\u003e32A Bi-Directional Type A Mini RCBO for FuseBox Consumer Units\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTAMB32BD\u003c\/strong\u003e is a compact \u003cstrong\u003e32A 30mA Type A bi-directional mini RCBO\u003c\/strong\u003e designed to provide combined residual current and overcurrent protection for individual circuits within compatible FuseBox consumer units.\u003c\/p\u003e\n\u003cp\u003eCombining the functions of an \u003cstrong\u003eMCB and RCD within a single protective device\u003c\/strong\u003e, the RTAMB32BD protects against \u003cstrong\u003eoverloads, short circuits and residual current \/ earth leakage faults\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIts \u003cstrong\u003ebi-directional operation\u003c\/strong\u003e allows the device to be used in appropriately designed installations where current may flow in either direction, making it particularly relevant to modern electrical systems incorporating \u003cstrong\u003esolar PV, renewable generation and other bi-directional power applications\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e32A Rated Current\u003c\/li\u003e\n\u003cli\u003e30mA Residual Operating Current\u003c\/li\u003e\n\u003cli\u003eType A Residual Current Protection\u003c\/li\u003e\n\u003cli\u003eBi-Directional Operation\u003c\/li\u003e\n\u003cli\u003eB Curve Tripping Characteristic\u003c\/li\u003e\n\u003cli\u003e6kA Short-Circuit Breaking Capacity\u003c\/li\u003e\n\u003cli\u003eCombined RCD \u0026amp; MCB Protection\u003c\/li\u003e\n\u003cli\u003eProtects Against Overloads\u003c\/li\u003e\n\u003cli\u003eProtects Against Short Circuits\u003c\/li\u003e\n\u003cli\u003eProtects Against Earth Leakage Faults\u003c\/li\u003e\n\u003cli\u003eDetects AC \u0026amp; Pulsating DC Residual Currents\u003c\/li\u003e\n\u003cli\u003eSuitable Where Current May Flow in Either Direction\u003c\/li\u003e\n\u003cli\u003eSuitable for Appropriate Solar PV Applications\u003c\/li\u003e\n\u003cli\u003e1P + N Switched Configuration\u003c\/li\u003e\n\u003cli\u003eLine \u0026amp; Neutral Switching\u003c\/li\u003e\n\u003cli\u003eCompact Mini RCBO Design\u003c\/li\u003e\n\u003cli\u003eSingle Module Width\u003c\/li\u003e\n\u003cli\u003e230V AC Rated Voltage\u003c\/li\u003e\n\u003cli\u003e50\/60Hz Operation\u003c\/li\u003e\n\u003cli\u003eIP20 Protection\u003c\/li\u003e\n\u003cli\u003e35mm DIN Rail Mounting\u003c\/li\u003e\n\u003cli\u003eDesigned for Compatible FuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eIEC 61009-1 \u0026amp; IEC 61009-2-2 Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBi-Directional Protection for Modern Electrical Systems\u003c\/h2\u003e\n\u003cp\u003eThe key advantage of the \u003cstrong\u003eFuseBox RTAMB32BD\u003c\/strong\u003e is its \u003cstrong\u003ebi-directional capability\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIn a traditional electrical circuit, power typically flows from the supply towards the connected load. Modern electrical installations can also incorporate local generation, meaning power may need to flow in either direction through parts of the installation.\u003c\/p\u003e\n\u003cp\u003eThe RTAMB32BD is designed to accommodate bi-directional power flow, making it a useful circuit protection solution for appropriately designed modern electrical and renewable energy systems.\u003c\/p\u003e\n\u003ch2\u003eIdeal for Solar PV Applications\u003c\/h2\u003e\n\u003cp\u003eSolar photovoltaic installations are a key example of where bi-directional circuit protection may be required.\u003c\/p\u003e\n\u003cp\u003eBecause a solar PV system generates electricity locally, power flow within the electrical installation can differ from that of a conventional load-only circuit.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003ebi-directional design\u003c\/strong\u003e of the RTAMB32BD makes it particularly relevant to appropriately designed \u003cstrong\u003esolar PV and renewable generation installations\u003c\/strong\u003e requiring a 32A Type A RCBO.\u003c\/p\u003e\n\u003ch2\u003eCombined RCBO Circuit Protection\u003c\/h2\u003e\n\u003cp\u003eThe RTAMB32BD combines \u003cstrong\u003eresidual current protection and overcurrent protection\u003c\/strong\u003e within one compact device.\u003c\/p\u003e\n\u003cp\u003eIt provides protection against:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOverloads\u003c\/li\u003e\n\u003cli\u003eShort Circuits\u003c\/li\u003e\n\u003cli\u003eResidual Current \/ Earth Leakage Faults\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUsing individual RCBOs also provides dedicated protection to each outgoing circuit rather than relying on a single shared RCD to provide residual current protection to several circuits.\u003c\/p\u003e\n\u003ch2\u003e30mA Type A Residual Current Protection\u003c\/h2\u003e\n\u003cp\u003eThe RTAMB32BD provides \u003cstrong\u003e30mA Type A residual current protection\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eType A RCBOs are designed to detect \u003cstrong\u003esinusoidal AC and pulsating DC residual currents\u003c\/strong\u003e, making them particularly relevant to contemporary installations incorporating electronic equipment.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e30mA residual operating current\u003c\/strong\u003e provides additional residual current protection for appropriately designed circuits.\u003c\/p\u003e\n\u003ch2\u003e32A B Curve Protection\u003c\/h2\u003e\n\u003cp\u003eWith a rated current of \u003cstrong\u003e32A\u003c\/strong\u003e, the RTAMB32BD features a \u003cstrong\u003eB Curve tripping characteristic\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIts 32A rating makes it suitable for appropriately designed circuits requiring this level of overcurrent protection.\u003c\/p\u003e\n\u003cp\u003eCorrect RCBO selection should always take account of factors including the connected load, conductor size, installation method, prospective fault current and applicable wiring requirements.\u003c\/p\u003e\n\u003ch2\u003e6kA Short-Circuit Breaking Capacity\u003c\/h2\u003e\n\u003cp\u003eThe FuseBox RTAMB32BD has a rated short-circuit breaking capacity of \u003cstrong\u003e6000A \/ 6kA\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis enables the device to provide short-circuit protection within installations where a 6kA protective device is appropriate.\u003c\/p\u003e\n\u003ch2\u003eCompact 1P+N Switched Design\u003c\/h2\u003e\n\u003cp\u003eThe RTAMB32BD features a \u003cstrong\u003e1P + N switched configuration\u003c\/strong\u003e, providing switching of both line and neutral.\u003c\/p\u003e\n\u003cp\u003eDespite incorporating overcurrent protection, residual current protection and switched-neutral functionality, its compact design occupies just \u003cstrong\u003eone module\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe mini RCBO format helps maximise available wiring and working space within the consumer unit, particularly where multiple outgoing circuits require individual RCBO protection.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e FuseBox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Code:\u003c\/strong\u003e RTAMB32BD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Bi-Directional Mini RCBO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 32A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Residual Operating Current:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCD Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperation:\u003c\/strong\u003e Bi-Directional\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristic:\u003c\/strong\u003e B Curve, 3–5 In\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Breaking Capacity:\u003c\/strong\u003e 6000A \/ 6kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 1P + N Switched\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine \u0026amp; Neutral Switching:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 230V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Rating:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Modules:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e 35mm DIN Rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Incoming Terminal Capacity:\u003c\/strong\u003e 16mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Outgoing Terminal Capacity:\u003c\/strong\u003e 10mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncoming Recommended Tightening Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutgoing Recommended Tightening Torque:\u003c\/strong\u003e 1.2Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNeutral Cable CSA:\u003c\/strong\u003e 2.5mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Endurance:\u003c\/strong\u003e 10,000 Operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e PA6 \/ Nylon 6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e Approx. 85 x 18 x 69.5mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e IEC 61009-1, IEC 61009-2-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eDomestic Electrical Installations\u003c\/li\u003e\n\u003cli\u003eAppropriate 32A Final Circuits\u003c\/li\u003e\n\u003cli\u003eSolar PV Installations\u003c\/li\u003e\n\u003cli\u003eRenewable Energy Systems\u003c\/li\u003e\n\u003cli\u003eApplications with Bi-Directional Power Flow\u003c\/li\u003e\n\u003cli\u003eResidential Properties\u003c\/li\u003e\n\u003cli\u003eNew-Build Electrical Installations\u003c\/li\u003e\n\u003cli\u003eConsumer Unit Upgrades\u003c\/li\u003e\n\u003cli\u003eIndividual Circuit Protection\u003c\/li\u003e\n\u003cli\u003eAppropriate Light Commercial Installations\u003c\/li\u003e\n\u003cli\u003eModern Electrical Distribution Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose the FuseBox RTAMB32BD?\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTAMB32BD\u003c\/strong\u003e combines \u003cstrong\u003e32A overcurrent protection, 30mA Type A residual current protection and bi-directional capability\u003c\/strong\u003e within a compact single-module protective device.\u003c\/p\u003e\n\u003cp\u003eIts bi-directional operation makes it particularly relevant to modern electrical installations where power may flow in either direction, including appropriately designed \u003cstrong\u003esolar PV and renewable energy systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eWith a \u003cstrong\u003eB Curve characteristic, 6kA breaking capacity and 1P+N switched configuration\u003c\/strong\u003e, the RTAMB32BD provides comprehensive individual circuit protection while making efficient use of valuable space inside the consumer unit.\u003c\/p\u003e","brand":"FuseBox Consumer Units \u0026 Circuit Protection","offers":[{"title":"Default Title","offer_id":54694372311386,"sku":"RTAMB32BD","price":20.02,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/RTAMB_20_BD_ANGLE_e93fe09029.webp?v=1788438224"},{"product_id":"fusebox-40a-30ma-type-a-b-curve-6ka-bi-directional-mini-rcbo-rtamb40bd","title":"FuseBox 40A 30mA Type A B Curve 6kA Bi-Directional Mini RCBO | RTAMB40BD","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eFuseBox 40A 30mA Type A B Curve 6kA Bi-Directional Mini RCBO | RTAMB40BD\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2\u003e40A Bi-Directional Type A Mini RCBO for FuseBox Consumer Units\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTAMB40BD\u003c\/strong\u003e is a compact \u003cstrong\u003e40A 30mA Type A bi-directional mini RCBO\u003c\/strong\u003e designed to provide combined residual current and overcurrent protection for individual circuits within compatible FuseBox consumer units.\u003c\/p\u003e\n\u003cp\u003eCombining the functions of an \u003cstrong\u003eMCB and RCD in a single protective device\u003c\/strong\u003e, the RTAMB40BD provides protection against \u003cstrong\u003eoverloads, short circuits and residual current \/ earth leakage faults\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIts \u003cstrong\u003ebi-directional operation\u003c\/strong\u003e makes it particularly relevant to modern electrical installations where current may flow in either direction, including appropriately designed \u003cstrong\u003esolar PV, renewable energy and distributed generation systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e40A Rated Current\u003c\/li\u003e\n\u003cli\u003e30mA Residual Operating Current\u003c\/li\u003e\n\u003cli\u003eType A Residual Current Protection\u003c\/li\u003e\n\u003cli\u003eBi-Directional Operation\u003c\/li\u003e\n\u003cli\u003eB Curve Tripping Characteristic\u003c\/li\u003e\n\u003cli\u003e6kA Short-Circuit Breaking Capacity\u003c\/li\u003e\n\u003cli\u003eCombined RCD \u0026amp; MCB Protection\u003c\/li\u003e\n\u003cli\u003eProtects Against Overloads\u003c\/li\u003e\n\u003cli\u003eProtects Against Short Circuits\u003c\/li\u003e\n\u003cli\u003eProtects Against Earth Leakage Faults\u003c\/li\u003e\n\u003cli\u003eDetects AC \u0026amp; Pulsating DC Residual Currents\u003c\/li\u003e\n\u003cli\u003eSuitable Where Current May Flow in Either Direction\u003c\/li\u003e\n\u003cli\u003eIdeal for Appropriate Solar PV Applications\u003c\/li\u003e\n\u003cli\u003e1P + N Switched Configuration\u003c\/li\u003e\n\u003cli\u003eLine \u0026amp; Neutral Switching\u003c\/li\u003e\n\u003cli\u003eCompact Mini RCBO Design\u003c\/li\u003e\n\u003cli\u003eSingle Module Width\u003c\/li\u003e\n\u003cli\u003e230V AC Rated Voltage\u003c\/li\u003e\n\u003cli\u003e50\/60Hz Operation\u003c\/li\u003e\n\u003cli\u003eIP20 Protection\u003c\/li\u003e\n\u003cli\u003e35mm DIN Rail Mounting\u003c\/li\u003e\n\u003cli\u003eDesigned for Compatible FuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eIEC 61009-1 \u0026amp; IEC 61009-2-2 Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBi-Directional Protection for Modern Installations\u003c\/h2\u003e\n\u003cp\u003eThe standout feature of the \u003cstrong\u003eFuseBox RTAMB40BD\u003c\/strong\u003e is its \u003cstrong\u003ebi-directional capability\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIn conventional electrical installations, electricity generally flows from the supply towards the connected load. However, modern installations incorporating local generation can require power to flow in either direction through parts of the electrical system.\u003c\/p\u003e\n\u003cp\u003eThe RTAMB40BD is designed to accommodate this bi-directional power flow, providing an appropriate circuit protection option where a \u003cstrong\u003e40A bi-directional RCBO\u003c\/strong\u003e is specified.\u003c\/p\u003e\n\u003ch2\u003eIdeal for Solar PV \u0026amp; Renewable Energy Systems\u003c\/h2\u003e\n\u003cp\u003eSolar PV and other distributed generation systems can introduce different power-flow requirements compared with conventional load-only circuits.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003ebi-directional design\u003c\/strong\u003e of the RTAMB40BD makes it particularly relevant to appropriately designed renewable energy installations where current may flow in either direction.\u003c\/p\u003e\n\u003cp\u003eIts \u003cstrong\u003e40A rating\u003c\/strong\u003e also provides an option for applications requiring a higher current rating than the smaller devices within the RTAMB bi-directional RCBO range.\u003c\/p\u003e\n\u003ch2\u003eCombined RCBO Circuit Protection\u003c\/h2\u003e\n\u003cp\u003eThe RTAMB40BD combines \u003cstrong\u003eresidual current protection and overcurrent protection\u003c\/strong\u003e within one compact device.\u003c\/p\u003e\n\u003cp\u003eIt provides protection against:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOverloads\u003c\/li\u003e\n\u003cli\u003eShort Circuits\u003c\/li\u003e\n\u003cli\u003eResidual Current \/ Earth Leakage Faults\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIndividual RCBO protection can also improve circuit separation by providing each outgoing circuit with dedicated residual current and overcurrent protection.\u003c\/p\u003e\n\u003ch2\u003e30mA Type A Residual Current Protection\u003c\/h2\u003e\n\u003cp\u003eThe RTAMB40BD provides \u003cstrong\u003e30mA Type A residual current protection\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eType A RCBOs are designed to detect \u003cstrong\u003esinusoidal AC and pulsating DC residual currents\u003c\/strong\u003e, making them particularly relevant to modern installations incorporating electronic equipment.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e30mA residual operating current\u003c\/strong\u003e provides additional residual current protection for appropriately designed circuits.\u003c\/p\u003e\n\u003ch2\u003e40A B Curve Protection\u003c\/h2\u003e\n\u003cp\u003eWith a rated current of \u003cstrong\u003e40A\u003c\/strong\u003e, the RTAMB40BD uses a \u003cstrong\u003eB Curve tripping characteristic\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIts 40A rating makes it suitable for appropriately designed circuits requiring this level of overcurrent protection.\u003c\/p\u003e\n\u003cp\u003eProtective device selection should always consider the connected load, conductor size, installation method, prospective fault current and applicable electrical installation requirements.\u003c\/p\u003e\n\u003ch2\u003e6kA Short-Circuit Breaking Capacity\u003c\/h2\u003e\n\u003cp\u003eThe FuseBox RTAMB40BD has a rated short-circuit breaking capacity of \u003cstrong\u003e6000A \/ 6kA\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis enables the device to provide short-circuit protection within electrical installations where a 6kA rated protective device is appropriate.\u003c\/p\u003e\n\u003ch2\u003eCompact 1P+N Switched Design\u003c\/h2\u003e\n\u003cp\u003eThe RTAMB40BD features a \u003cstrong\u003e1P + N switched configuration\u003c\/strong\u003e, providing switching of both line and neutral.\u003c\/p\u003e\n\u003cp\u003eDespite combining residual current protection, overcurrent protection and switched-neutral functionality, the compact mini RCBO occupies only \u003cstrong\u003eone module\u003c\/strong\u003e within the consumer unit.\u003c\/p\u003e\n\u003cp\u003eThis space-saving design helps provide additional wiring and working room, particularly where multiple outgoing circuits require individual RCBO protection.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e FuseBox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Code:\u003c\/strong\u003e RTAMB40BD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Bi-Directional Mini RCBO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 40A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Residual Operating Current:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCD Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperation:\u003c\/strong\u003e Bi-Directional\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristic:\u003c\/strong\u003e B Curve, 3–5 In\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Breaking Capacity:\u003c\/strong\u003e 6000A \/ 6kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 1P + N Switched\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine \u0026amp; Neutral Switching:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 230V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Rating:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Modules:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e 35mm DIN Rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Incoming Terminal Capacity:\u003c\/strong\u003e 16mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Outgoing Terminal Capacity:\u003c\/strong\u003e 10mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncoming Recommended Tightening Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutgoing Recommended Tightening Torque:\u003c\/strong\u003e 1.2Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNeutral Cable CSA:\u003c\/strong\u003e 2.5mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Endurance:\u003c\/strong\u003e 10,000 Operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e PA6 \/ Nylon 6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e Approx. 85 x 18 x 69.5mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e IEC 61009-1, IEC 61009-2-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eDomestic Electrical Installations\u003c\/li\u003e\n\u003cli\u003eAppropriate 40A Final Circuits\u003c\/li\u003e\n\u003cli\u003eSolar PV Installations\u003c\/li\u003e\n\u003cli\u003eRenewable Energy Systems\u003c\/li\u003e\n\u003cli\u003eDistributed Generation Systems\u003c\/li\u003e\n\u003cli\u003eApplications with Bi-Directional Power Flow\u003c\/li\u003e\n\u003cli\u003eResidential Properties\u003c\/li\u003e\n\u003cli\u003eNew-Build Electrical Installations\u003c\/li\u003e\n\u003cli\u003eConsumer Unit Upgrades\u003c\/li\u003e\n\u003cli\u003eIndividual Circuit Protection\u003c\/li\u003e\n\u003cli\u003eAppropriate Light Commercial Installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose the FuseBox RTAMB40BD?\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTAMB40BD\u003c\/strong\u003e combines \u003cstrong\u003e40A overcurrent protection, 30mA Type A residual current protection and bi-directional operation\u003c\/strong\u003e within a compact single-module device.\u003c\/p\u003e\n\u003cp\u003eIts bi-directional capability makes it particularly relevant to modern electrical systems where current may flow in either direction, including appropriately designed \u003cstrong\u003esolar PV and renewable energy installations\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eWith a \u003cstrong\u003eB Curve characteristic, 6kA breaking capacity and 1P+N switched configuration\u003c\/strong\u003e, the RTAMB40BD delivers comprehensive individual circuit protection while making efficient use of available consumer unit space.\u003c\/p\u003e","brand":"FuseBox Consumer Units \u0026 Circuit Protection","offers":[{"title":"Default Title","offer_id":54694380110170,"sku":"RTAMB40BD","price":20.02,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/RTAMB_20_BD_ANGLE_e93fe09029.webp?v=1788438224"},{"product_id":"fusebox-100a-fused-switch-with-type-2-spd-63a-80a-100a-fuses-sf0100t2","title":"FuseBox 100A Fused Switch with Type 2 SPD \u0026 63A, 80A, 100A Fuses | SF0100T2","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eFuseBox 100A Fused Switch with Type 2 SPD \u0026amp; 63A, 80A, 100A Fuses | SF0100T2\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2\u003e100A Fused Switch with Integrated Type 2 Surge Protection\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox SF0100T2\u003c\/strong\u003e is a \u003cstrong\u003e100A 1P+N fused switch with integrated Type 2 Surge Protection Device (SPD)\u003c\/strong\u003e, providing isolation, fuse protection and surge protection within one robust metal enclosure.\u003c\/p\u003e\n\u003cp\u003eSupplied complete with \u003cstrong\u003e63A, 80A and 100A gG cylindrical fuses\u003c\/strong\u003e, the SF0100T2 gives installers the flexibility to select the appropriate fuse rating for the installation. FuseBox specifies a maximum load of \u003cstrong\u003e100A \/ AC21\u003c\/strong\u003e, with the unit incorporating a Type 2 SPD as standard. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe steel enclosure, generous cable capacity, integrated surge protection and padlock facility make this an excellent solution for appropriately designed domestic and commercial electrical distribution installations.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e100A Fused Switch\u003c\/li\u003e\n\u003cli\u003eIntegrated Type 2 SPD\u003c\/li\u003e\n\u003cli\u003e1 Pole + Neutral Configuration\u003c\/li\u003e\n\u003cli\u003eMaximum Load of 100A \/ AC21\u003c\/li\u003e\n\u003cli\u003eSupplied with 63A gG Fuse\u003c\/li\u003e\n\u003cli\u003eSupplied with 80A gG Fuse\u003c\/li\u003e\n\u003cli\u003eSupplied with 100A gG Fuse\u003c\/li\u003e\n\u003cli\u003e22 x 58mm Cylindrical Fuse Format\u003c\/li\u003e\n\u003cli\u003egG General-Purpose Fuses for Conductor Protection\u003c\/li\u003e\n\u003cli\u003eRobust Steel Enclosure\u003c\/li\u003e\n\u003cli\u003eIP20 Rated\u003c\/li\u003e\n\u003cli\u003eMain Switch Terminal Capacity up to 35mm²\u003c\/li\u003e\n\u003cli\u003eFuse Holder Terminal Capacity up to 35mm²\u003c\/li\u003e\n\u003cli\u003eEarth Terminal Capacity up to 16mm²\u003c\/li\u003e\n\u003cli\u003eTop \u0026amp; Bottom Cable Entry Knockouts\u003c\/li\u003e\n\u003cli\u003ePadlock Facility\u003c\/li\u003e\n\u003cli\u003eSuitable for Incoming Supply Isolation\u003c\/li\u003e\n\u003cli\u003eBS EN 61439-3 Consumer Unit Standard\u003c\/li\u003e\n\u003cli\u003eIEC\/EN 60947-3 Main Switch\u003c\/li\u003e\n\u003cli\u003eIEC 60947-3 Fuse Holder\u003c\/li\u003e\n\u003cli\u003eIEC 60269-2 Fuses\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFuseBox's current documentation confirms that the \u003cstrong\u003eSF0100T2 includes the Type 2 SPD plus all three 63A, 80A and 100A gG fuses\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eFused Switching up to 100A\u003c\/h2\u003e\n\u003cp\u003eThe SF0100T2 combines a \u003cstrong\u003e100A rated switch with a dedicated fuse holder\u003c\/strong\u003e, allowing the outgoing supply to receive overcurrent protection using the appropriate supplied fuse.\u003c\/p\u003e\n\u003cp\u003eFuseBox supplies three fuse ratings with the unit:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e63A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e80A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e100A\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAll three are \u003cstrong\u003e22 x 58mm cylindrical gG fuses\u003c\/strong\u003e, with gG being a general-purpose fuse classification suitable for conductor protection. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis gives installers greater flexibility when configuring the unit according to the requirements of the installation.\u003c\/p\u003e\n\u003ch2\u003eIntegrated Type 2 Surge Protection Device\u003c\/h2\u003e\n\u003cp\u003eUnlike the standard SF0100 fused switch, the \u003cstrong\u003eSF0100T2 incorporates a Type 2 SPD\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe integrated surge protection device helps protect the electrical installation and connected equipment against transient overvoltages, providing surge protection alongside the unit's switching and fuse protection functions. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis combined design can provide a neat and convenient solution where a fused switch and Type 2 surge protection are required at the same point in the installation.\u003c\/p\u003e\n\u003ch2\u003e100A \/ AC21 Maximum Load\u003c\/h2\u003e\n\u003cp\u003eFuseBox specifies the SF0100T2 with a \u003cstrong\u003emaximum load of 100A \/ AC21\u003c\/strong\u003e and a \u003cstrong\u003e1P+N configuration\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe fuse rating should be selected according to the electrical installation requirements, with 63A, 80A and 100A options supplied with the unit.\u003c\/p\u003e\n\u003ch2\u003eRobust Steel Enclosure\u003c\/h2\u003e\n\u003cp\u003eThe SF0100T2 is housed within a durable \u003cstrong\u003esteel enclosure\u003c\/strong\u003e, providing a professional and robust solution for electrical distribution applications.\u003c\/p\u003e\n\u003cp\u003eThe enclosure measures \u003cstrong\u003e314mm high x 236mm wide x 88mm deep\u003c\/strong\u003e according to FuseBox's current installation leaflet. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eFlexible Cable Entry\u003c\/h2\u003e\n\u003cp\u003eFor convenient installation, the enclosure provides \u003cstrong\u003e1 x 20mm and 1 x 32mm knockout at both the top and bottom\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis gives installers flexibility when routing incoming and outgoing cables while helping maintain a neat installation. FuseBox recommends the use of appropriate glands to maintain the enclosure's protection and fire-containment properties. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eGenerous Terminal Capacity\u003c\/h2\u003e\n\u003cp\u003eDesigned to accommodate substantial supply conductors, the SF0100T2 provides generous connection capacity.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003emain switch and fuse holder both accept conductors up to 35mm²\u003c\/strong\u003e, while the earth terminals accommodate up to \u003cstrong\u003e16mm²\u003c\/strong\u003e. FuseBox specifies recommended tightening torques of 2.5Nm for the main switch, 4.0Nm for the fuse holder and 2.5Nm for the earth terminals. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003ePadlock Facility\u003c\/h2\u003e\n\u003cp\u003eThe enclosure incorporates a \u003cstrong\u003epadlock facility\u003c\/strong\u003e, providing an additional option for securing the switch where isolation procedures require it. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e FuseBox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Code:\u003c\/strong\u003e SF0100T2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Fused Switch with Type 2 SPD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Load:\u003c\/strong\u003e 100A \/ AC21\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSPD:\u003c\/strong\u003e Type 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Ratings Supplied:\u003c\/strong\u003e 63A, 80A \u0026amp; 100A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Type:\u003c\/strong\u003e gG – General Purpose for Conductor Protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Size:\u003c\/strong\u003e 22 x 58mm Cylindrical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Material:\u003c\/strong\u003e Steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Rating:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain Switch Maximum Cable Capacity:\u003c\/strong\u003e 35mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Holder Maximum Cable Capacity:\u003c\/strong\u003e 35mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth Terminal Maximum Cable Capacity:\u003c\/strong\u003e 16mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain Switch Recommended Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Holder Recommended Torque:\u003c\/strong\u003e 4.0Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth Terminal Recommended Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTop Cable Entries:\u003c\/strong\u003e 1 x 20mm + 1 x 32mm Knockouts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBottom Cable Entries:\u003c\/strong\u003e 1 x 20mm + 1 x 32mm Knockouts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePadlock Facility:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e 314 x 236 x 88mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConsumer Unit Standard:\u003c\/strong\u003e BS EN 61439-3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain Switch Standard:\u003c\/strong\u003e IEC\/EN 60947-3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Holder Standard:\u003c\/strong\u003e IEC 60947-3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Standard:\u003c\/strong\u003e IEC 60269-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese specifications are taken from FuseBox's current SF0100\/SF0100T2 installation documentation. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDomestic Electrical Installations\u003c\/li\u003e\n\u003cli\u003eCommercial Electrical Installations\u003c\/li\u003e\n\u003cli\u003eIncoming Supply Isolation\u003c\/li\u003e\n\u003cli\u003eSub-Main Distribution\u003c\/li\u003e\n\u003cli\u003eFused Supply Protection\u003c\/li\u003e\n\u003cli\u003eInstallations Requiring Type 2 Surge Protection\u003c\/li\u003e\n\u003cli\u003eConsumer Unit Supply Arrangements\u003c\/li\u003e\n\u003cli\u003eElectrical Distribution Upgrades\u003c\/li\u003e\n\u003cli\u003eNew-Build Electrical Installations\u003c\/li\u003e\n\u003cli\u003eAppropriate Outbuildings \u0026amp; Sub-Buildings\u003c\/li\u003e\n\u003cli\u003eInstallations Requiring 63A, 80A or 100A Fuse Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose the FuseBox SF0100T2?\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox SF0100T2\u003c\/strong\u003e provides a convenient combination of \u003cstrong\u003e100A fused switching and Type 2 surge protection within a single robust steel enclosure\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eSupplied with \u003cstrong\u003e63A, 80A and 100A gG fuses\u003c\/strong\u003e, it offers useful flexibility when selecting the appropriate fuse rating for the installation. Its \u003cstrong\u003e35mm² main switch and fuse holder capacity, padlock facility and flexible top and bottom cable entries\u003c\/strong\u003e also make it installer-friendly.\u003c\/p\u003e\n\u003cp\u003eFor projects requiring a \u003cstrong\u003eFuseBox fused switch with integrated Type 2 SPD\u003c\/strong\u003e, the SF0100T2 provides switching, fuse protection and surge protection in one purpose-designed assembly.\u003c\/p\u003e","brand":"FuseBox Consumer Units \u0026 Circuit Protection","offers":[{"title":"Default Title","offer_id":54694428311898,"sku":"SF0100T2","price":132.62,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/SF_0100_T2_ANGLE_OPEN_LH_54f8be97fb.webp?v=1788439062"},{"product_id":"fusebox-2-pole-100a-main-switch-enclosed-ip20-meter-isolator-e2pmsh","title":"FuseBox 2 Pole 100A Main Switch Enclosed IP20 Meter Isolator | E2PMSH","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eFuseBox 2 Pole 100A Main Switch Enclosed IP20 Meter Isolator | E2PMSH\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2\u003eCompact 100A Double Pole Main Switch for Meter Tail Isolation\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox E2PMSH\u003c\/strong\u003e is a compact \u003cstrong\u003e2 pole 100A enclosed main switch and meter isolator\u003c\/strong\u003e, designed to provide a convenient point of isolation between the electricity meter and consumer unit.\u003c\/p\u003e\n\u003cp\u003eRated at \u003cstrong\u003e100A AC22A\u003c\/strong\u003e, the E2PMSH simultaneously isolates both conductors in a single-phase installation and is specifically designed for use with \u003cstrong\u003e16mm² and 25mm² double-insulated meter tails\u003c\/strong\u003e. Its compact \u003cstrong\u003eIP20 polycarbonate enclosure\u003c\/strong\u003e makes it ideal for indoor meter cupboards, service positions and other locations where space is limited. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe enclosure also features a \u003cstrong\u003esplit cover, top and bottom cable entry points and wire-sealing provision\u003c\/strong\u003e, providing a practical, installer-friendly solution for meter isolation and main switching applications. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e100A Rated Main Switch\u003c\/li\u003e\n\u003cli\u003e2 Pole \/ Double Pole Configuration\u003c\/li\u003e\n\u003cli\u003e100A AC22A Rating\u003c\/li\u003e\n\u003cli\u003eSuitable as a Meter Isolator\u003c\/li\u003e\n\u003cli\u003eSimultaneous Line \u0026amp; Neutral Isolation\u003c\/li\u003e\n\u003cli\u003eDesigned for Single-Phase Installations\u003c\/li\u003e\n\u003cli\u003eIP20 Rated Enclosure\u003c\/li\u003e\n\u003cli\u003eCompact Polycarbonate Housing\u003c\/li\u003e\n\u003cli\u003eSplit Cover Design\u003c\/li\u003e\n\u003cli\u003eDesigned for 16mm² \u0026amp; 25mm² Double-Insulated Meter Tails\u003c\/li\u003e\n\u003cli\u003e35mm² Maximum Terminal Capacity\u003c\/li\u003e\n\u003cli\u003eTop \u0026amp; Bottom Cable Entry Points\u003c\/li\u003e\n\u003cli\u003eWire-Sealing Facility\u003c\/li\u003e\n\u003cli\u003e6000V Rated Impulse Withstand Voltage\u003c\/li\u003e\n\u003cli\u003e20,000 Operation Mechanical Endurance\u003c\/li\u003e\n\u003cli\u003eCompact 150 x 50 x 83mm Size\u003c\/li\u003e\n\u003cli\u003eIndoor Installation\u003c\/li\u003e\n\u003cli\u003eIEC 60947-3 \/ EN 62208 Compliant \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e100A Double Pole Isolation\u003c\/h2\u003e\n\u003cp\u003eThe E2PMSH incorporates a \u003cstrong\u003e2 pole 100A main switch\u003c\/strong\u003e, allowing both conductors to be disconnected when the isolator is operated.\u003c\/p\u003e\n\u003cp\u003eThis provides a convenient means of isolating the electrical installation downstream of the meter, allowing work to be carried out without routinely needing to disturb the upstream supply fuse.\u003c\/p\u003e\n\u003cp\u003eWith a rated operational current of \u003cstrong\u003e100A AC22A\u003c\/strong\u003e, the unit is suitable for appropriately designed installations up to its specified rating. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eDesigned for Meter Tails\u003c\/h2\u003e\n\u003cp\u003eFuseBox specifically designs the E2PMSH for use with \u003cstrong\u003e16mm² and 25mm² double-insulated meter tails\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe main switch terminals can accommodate conductors up to \u003cstrong\u003e35mm²\u003c\/strong\u003e, providing generous connection capacity, while top and bottom entry points help simplify cable routing during installation. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eCompact IP20 Polycarbonate Enclosure\u003c\/h2\u003e\n\u003cp\u003eThe main switch is supplied ready-mounted inside a compact \u003cstrong\u003eIP20 polycarbonate enclosure\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eAt approximately \u003cstrong\u003e150mm high, 50mm wide and 83mm deep\u003c\/strong\u003e, the E2PMSH requires relatively little wall space, making it particularly useful for meter cupboards and service areas where installation space may be restricted. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe enclosure is intended for \u003cstrong\u003eindoor installation\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSplit Cover with Wire-Sealing Facility\u003c\/h2\u003e\n\u003cp\u003eThe E2PMSH features a practical \u003cstrong\u003esplit-cover enclosure\u003c\/strong\u003e with provision for a wire or plastic seal through the tamper-resistant screw.\u003c\/p\u003e\n\u003cp\u003eThis makes the unit particularly well suited to meter isolation applications while providing straightforward access during installation and authorised maintenance. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eHigh Mechanical Endurance\u003c\/h2\u003e\n\u003cp\u003eFuseBox specifies the E2PMSH with a \u003cstrong\u003emechanical endurance of 20,000 operations\u003c\/strong\u003e, providing a durable switching solution for long-term installation.\u003c\/p\u003e\n\u003cp\u003eThe unit is designed to operate across temperatures from \u003cstrong\u003e-25°C to +40°C\u003c\/strong\u003e, with a specified storage range of \u003cstrong\u003e-25°C to +70°C\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e FuseBox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Code:\u003c\/strong\u003e E2PMSH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Enclosed Main Switch \/ Meter Isolator\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 100A AC22A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 2P\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 230\/400V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Rating:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Impulse Withstand Voltage:\u003c\/strong\u003e 6000V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Endurance:\u003c\/strong\u003e 20,000 Operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Terminal Capacity:\u003c\/strong\u003e 35mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended Main Switch Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFront Cover Hex Screw Torque:\u003c\/strong\u003e 0.75Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable Meter Tails:\u003c\/strong\u003e 16mm² \u0026amp; 25mm² Double Insulated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Material:\u003c\/strong\u003e Polycarbonate (PC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlow Wire Temperature:\u003c\/strong\u003e 960°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -25°C to +40°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -25°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Entry:\u003c\/strong\u003e Top \u0026amp; Bottom\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Seal Facility:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e 150 x 50 x 83mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 262g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN \/ EAN:\u003c\/strong\u003e 5060523526451\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e IEC 60947-3 \/ EN 62208 \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectricity Meter Isolation\u003c\/li\u003e\n\u003cli\u003eConsumer Unit Supply Isolation\u003c\/li\u003e\n\u003cli\u003eDomestic Electrical Installations\u003c\/li\u003e\n\u003cli\u003eSingle-Phase Electrical Supplies\u003c\/li\u003e\n\u003cli\u003eMeter Cupboards\u003c\/li\u003e\n\u003cli\u003eConsumer Unit Replacements\u003c\/li\u003e\n\u003cli\u003eElectrical Installation Upgrades\u003c\/li\u003e\n\u003cli\u003eNew-Build Properties\u003c\/li\u003e\n\u003cli\u003eResidential Installations\u003c\/li\u003e\n\u003cli\u003eAppropriate Light Commercial Installations\u003c\/li\u003e\n\u003cli\u003e16mm² Meter Tail Installations\u003c\/li\u003e\n\u003cli\u003e25mm² Meter Tail Installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose the FuseBox E2PMSH?\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox E2PMSH\u003c\/strong\u003e provides a simple and compact way to introduce \u003cstrong\u003e100A double pole isolation\u003c\/strong\u003e between an electricity meter and downstream electrical installation.\u003c\/p\u003e\n\u003cp\u003eIts combination of a \u003cstrong\u003e100A AC22A main switch, IP20 polycarbonate enclosure, compatibility with 16mm² and 25mm² meter tails, 35mm² terminal capacity and compact 150 x 50mm footprint\u003c\/strong\u003e makes it particularly practical for meter cupboards and restricted installation spaces. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003esplit-cover design, top and bottom cable entries and wire-sealing facility\u003c\/strong\u003e further enhance its suitability for professional meter isolation installations.\u003c\/p\u003e","brand":"FuseBox Consumer Units \u0026 Circuit Protection","offers":[{"title":"Default Title","offer_id":54694446956890,"sku":"E2PMSH","price":11.24,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/E2_PMSH_STRAIGHT_ebcf8c1749.webp?v=1788439383"},{"product_id":"fusebox-80a-fused-switch-1p-n-with-cable-shroud-me80-fuse-fms080","title":"FuseBox 80A Fused Switch 1P+N with Cable Shroud \u0026 ME80 Fuse | FMS080","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eFuseBox 80A Fused Switch 1P+N with Cable Shroud \u0026amp; ME80 Fuse | FMS080\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2\u003eCompact 80A Fused Switch for Domestic Electrical Installations\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox FMS080\u003c\/strong\u003e is an \u003cstrong\u003e80A 1P+N fused switch\u003c\/strong\u003e supplied complete with a \u003cstrong\u003ecable shroud and Lawson ME80 80A fuse\u003c\/strong\u003e, providing switching and fused overcurrent protection in a compact unit.\u003c\/p\u003e\n\u003cp\u003eDesigned primarily for domestic electrical applications, the FMS080 operates at \u003cstrong\u003e230V \/ 50Hz\u003c\/strong\u003e and provides a maximum load rating of \u003cstrong\u003e80A AC21\u003c\/strong\u003e. Its compact construction, 25mm² maximum cable capacity and included fuse make it a convenient solution for appropriately designed supply and distribution arrangements. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e80A Fused Switch\u003c\/li\u003e\n\u003cli\u003e1 Pole + Neutral Configuration\u003c\/li\u003e\n\u003cli\u003eSupplied with Lawson ME80 80A Fuse\u003c\/li\u003e\n\u003cli\u003eCable Shroud Included\u003c\/li\u003e\n\u003cli\u003e22 x 58mm Fuse Format\u003c\/li\u003e\n\u003cli\u003e80A Maximum AC21 Rating\u003c\/li\u003e\n\u003cli\u003e230V \/ 50Hz\u003c\/li\u003e\n\u003cli\u003e500V Rated Insulation Voltage\u003c\/li\u003e\n\u003cli\u003e25mm² Maximum Cable Capacity\u003c\/li\u003e\n\u003cli\u003e2.5Nm Terminal Torque\u003c\/li\u003e\n\u003cli\u003eIP20 Rated\u003c\/li\u003e\n\u003cli\u003eUrea Construction\u003c\/li\u003e\n\u003cli\u003eCompact 80 x 128 x 63mm Design\u003c\/li\u003e\n\u003cli\u003eSuitable for Domestic Applications\u003c\/li\u003e\n\u003cli\u003eManufactured to BS EN 60947-3\u003c\/li\u003e\n\u003cli\u003eCable Tidy Supplied\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFuseBox's technical data identifies the FMS080 specifically as an \u003cstrong\u003e80A fused switch, 1P+N, supplied with shroud and ME80 fuse\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSupplied with Lawson ME80 80A Fuse\u003c\/h2\u003e\n\u003cp\u003eA key advantage of the \u003cstrong\u003eFMS080\u003c\/strong\u003e is that the required \u003cstrong\u003eLawson ME80 80A fuse\u003c\/strong\u003e is supplied with the unit.\u003c\/p\u003e\n\u003cp\u003eThe manufacturer specifies an \u003cstrong\u003e80A ME-type fuse in the 22 x 58mm format\u003c\/strong\u003e, giving installers a complete fused-switch solution without needing to source the specified fuse separately. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe fuse provides overcurrent protection for the connected circuit, while the switching mechanism provides convenient isolation.\u003c\/p\u003e\n\u003ch2\u003e80A 1P+N Switching\u003c\/h2\u003e\n\u003cp\u003eThe FuseBox FMS080 has a \u003cstrong\u003e1 pole + neutral configuration\u003c\/strong\u003e and a maximum current rating of \u003cstrong\u003e80A AC21\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis makes it suitable for appropriately designed single-phase domestic electrical installations requiring combined switching and fuse protection. The device has a rated operating voltage of \u003cstrong\u003e230V at 50Hz\u003c\/strong\u003e and a rated insulation voltage of \u003cstrong\u003e500V\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eCable Shroud Included\u003c\/h2\u003e\n\u003cp\u003eThe FMS080 is supplied complete with a \u003cstrong\u003ecable shroud\u003c\/strong\u003e, helping provide a neat and protected installation around the cable termination area.\u003c\/p\u003e\n\u003cp\u003eA cable tidy is also supplied, further assisting installers in achieving an organised finished installation. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e25mm² Maximum Cable Capacity\u003c\/h2\u003e\n\u003cp\u003eThe FMS080 accommodates conductors up to \u003cstrong\u003e25mm²\u003c\/strong\u003e, making it suitable for the substantial cable sizes typically associated with higher-current domestic distribution applications.\u003c\/p\u003e\n\u003cp\u003eFuseBox specifies a \u003cstrong\u003e2.5Nm terminal tightening torque\u003c\/strong\u003e for the unit. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eCompact IP20 Construction\u003c\/h2\u003e\n\u003cp\u003eWith dimensions of just \u003cstrong\u003e80mm high x 128mm wide x 63mm deep\u003c\/strong\u003e, the FMS080 provides its switching and fuse protection functions within a relatively compact footprint.\u003c\/p\u003e\n\u003cp\u003eThe unit is manufactured from \u003cstrong\u003eurea\u003c\/strong\u003e and carries an \u003cstrong\u003eIP20 rating\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSafety-Focused Switch Design\u003c\/h2\u003e\n\u003cp\u003eThe FMS080's lid is designed so that it can only be removed when the switch is in the \u003cstrong\u003eOFF position\u003c\/strong\u003e, providing a useful safety feature during access and maintenance. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFuseBox also specifies that the fuse \u003cstrong\u003emust not be installed or removed while under load\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e FuseBox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Code:\u003c\/strong\u003e FMS080\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Fused Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 80A Maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUtilisation Category:\u003c\/strong\u003e AC21\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Insulation Voltage (Ui):\u003c\/strong\u003e 500V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Supplied:\u003c\/strong\u003e Lawson ME80\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Rating:\u003c\/strong\u003e 80A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Type:\u003c\/strong\u003e ME Type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Size:\u003c\/strong\u003e 22 x 58mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Shroud:\u003c\/strong\u003e Included\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Cable Capacity:\u003c\/strong\u003e 25mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Rating:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Urea\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Domestic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e 80 x 128 x 63mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.75kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBarcode \/ GTIN:\u003c\/strong\u003e 5060523523009\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitch Standard:\u003c\/strong\u003e BS EN 60947-3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Standards:\u003c\/strong\u003e BS HD 60269-3:2010+A1:2013 \/ BS 88-3:2010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe principal specifications above are taken from the FuseBox FMS080 technical data sheet. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDomestic Electrical Installations\u003c\/li\u003e\n\u003cli\u003eFused Supply Protection\u003c\/li\u003e\n\u003cli\u003eElectrical Distribution\u003c\/li\u003e\n\u003cli\u003eAppropriate Sub-Main Circuits\u003c\/li\u003e\n\u003cli\u003eSupply Isolation\u003c\/li\u003e\n\u003cli\u003eResidential Properties\u003c\/li\u003e\n\u003cli\u003eConsumer Unit Installations\u003c\/li\u003e\n\u003cli\u003eElectrical Installation Upgrades\u003c\/li\u003e\n\u003cli\u003eNew-Build Properties\u003c\/li\u003e\n\u003cli\u003eInstallations Requiring 80A Fuse Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose the FuseBox FMS080?\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox FMS080\u003c\/strong\u003e provides a straightforward combination of \u003cstrong\u003e80A switching and fused protection\u003c\/strong\u003e in a compact, installer-friendly format.\u003c\/p\u003e\n\u003cp\u003eSupplied complete with the \u003cstrong\u003eLawson ME80 80A fuse, cable shroud and cable tidy\u003c\/strong\u003e, the unit provides the essential components required for a professional installation. Its \u003cstrong\u003e1P+N configuration, 25mm² terminal capacity and compact 80 x 128 x 63mm dimensions\u003c\/strong\u003e make it particularly useful where space is at a premium.\u003c\/p\u003e","brand":"FuseBox Consumer Units \u0026 Circuit Protection","offers":[{"title":"Default Title","offer_id":54694478741850,"sku":"FMS080","price":16.66,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/FMS_080_164e4236dc.webp?v=1788439640"},{"product_id":"fusebox-din-rail-blank-1-module-adrb","title":"FuseBox DIN Rail Blank 1 Module | ADRB","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eFuseBox DIN Rail Blank 1 Module | ADRB\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2\u003e1 Module DIN Rail Blank for FuseBox Consumer Units\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox ADRB\u003c\/strong\u003e is a \u003cstrong\u003e1 module DIN rail blank\u003c\/strong\u003e designed for use within compatible FuseBox consumer units and distribution equipment.\u003c\/p\u003e\n\u003cp\u003eIt provides a simple and professional way to \u003cstrong\u003ecover unused module spaces\u003c\/strong\u003e where a protective device is not installed, helping maintain a neat and properly finished consumer unit installation.\u003c\/p\u003e\n\u003cp\u003eDesigned to fit onto the \u003cstrong\u003eDIN rail\u003c\/strong\u003e, the ADRB is a useful accessory for new installations, consumer unit alterations and upgrades where spare ways need to be blanked off.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 Module DIN Rail Blank\u003c\/li\u003e\n\u003cli\u003eDesigned for FuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eCovers Unused Module Spaces\u003c\/li\u003e\n\u003cli\u003eDIN Rail Mounted\u003c\/li\u003e\n\u003cli\u003eHelps Create a Neat, Professional Finish\u003c\/li\u003e\n\u003cli\u003eIdeal for Spare Ways\u003c\/li\u003e\n\u003cli\u003eQuick \u0026amp; Straightforward Installation\u003c\/li\u003e\n\u003cli\u003eSuitable for New Installations \u0026amp; Upgrades\u003c\/li\u003e\n\u003cli\u003eGenuine FuseBox Accessory\u003c\/li\u003e\n\u003cli\u003eCompact Design\u003c\/li\u003e\n\u003cli\u003eUseful Consumer Unit Installation Accessory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCover Unused Consumer Unit Ways\u003c\/h2\u003e\n\u003cp\u003eUnused spaces within a consumer unit should be appropriately covered rather than left open.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox ADRB\u003c\/strong\u003e provides a convenient solution, occupying a \u003cstrong\u003esingle module space\u003c\/strong\u003e and helping create a clean, complete finish inside compatible FuseBox distribution equipment.\u003c\/p\u003e\n\u003cp\u003eThis makes it particularly useful where the consumer unit has been deliberately selected with spare capacity for future expansion.\u003c\/p\u003e\n\u003ch2\u003e1 Module Design\u003c\/h2\u003e\n\u003cp\u003eThe ADRB is designed to occupy \u003cstrong\u003eone module\u003c\/strong\u003e, allowing individual spare positions to be covered without unnecessarily blanking neighbouring ways.\u003c\/p\u003e\n\u003cp\u003eMultiple blanks can be used where more than one unused module needs to be covered, giving installers flexibility when configuring the consumer unit.\u003c\/p\u003e\n\u003ch2\u003eDIN Rail Mounting\u003c\/h2\u003e\n\u003cp\u003eUnlike fascia-only blanking plates, the \u003cstrong\u003eADRB is a DIN rail blank\u003c\/strong\u003e, allowing it to be fitted directly to the DIN rail within the enclosure.\u003c\/p\u003e\n\u003cp\u003eThis provides a secure and straightforward installation while maintaining an organised appearance alongside the installed circuit protection devices.\u003c\/p\u003e\n\u003ch2\u003eIdeal for Consumer Unit Upgrades\u003c\/h2\u003e\n\u003cp\u003eThe FuseBox ADRB is a useful accessory when installing, modifying or upgrading FuseBox consumer units.\u003c\/p\u003e\n\u003cp\u003eWhere circuits are removed or spare capacity is deliberately retained for future expansion, the blank can be used to cover the unused module position until another protective device is required.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e FuseBox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Code:\u003c\/strong\u003e ADRB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e DIN Rail Blank\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Width:\u003c\/strong\u003e 1 Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Type:\u003c\/strong\u003e DIN Rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Consumer Unit \/ Distribution Equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePurpose:\u003c\/strong\u003e Covering Unused Module Spaces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Compatible FuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Type:\u003c\/strong\u003e Internal Consumer Unit Accessory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eElectrical Distribution Equipment\u003c\/li\u003e\n\u003cli\u003eCovering Unused Consumer Unit Ways\u003c\/li\u003e\n\u003cli\u003eSpare Module Positions\u003c\/li\u003e\n\u003cli\u003eDomestic Electrical Installations\u003c\/li\u003e\n\u003cli\u003eConsumer Unit Upgrades\u003c\/li\u003e\n\u003cli\u003eNew-Build Electrical Installations\u003c\/li\u003e\n\u003cli\u003eConsumer Unit Alterations\u003c\/li\u003e\n\u003cli\u003eFuture Circuit Provision\u003c\/li\u003e\n\u003cli\u003eAppropriate Light Commercial Installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose the FuseBox ADRB?\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox ADRB\u003c\/strong\u003e is a simple but important finishing accessory for compatible FuseBox consumer units.\u003c\/p\u003e\n\u003cp\u003eIts \u003cstrong\u003esingle-module DIN rail design\u003c\/strong\u003e allows an unused position to be covered neatly while retaining spare capacity for future circuit additions.\u003c\/p\u003e\n\u003cp\u003eFor installers working with FuseBox consumer units, the ADRB provides a convenient way to achieve a \u003cstrong\u003etidy, professional finish\u003c\/strong\u003e without permanently sacrificing the unused module position.\u003c\/p\u003e","brand":"FuseBox Consumer Units \u0026 Circuit Protection","offers":[{"title":"Default Title","offer_id":54694543425882,"sku":"ADRB","price":0.64,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/ADRB_41635f48af.webp?v=1788440305"},{"product_id":"fusebox-type-2-spd-direct-to-busbar-connection-max-100a-spd1mt2","title":"FuseBox Type 2 SPD Direct to Busbar Connection Max 100A | SPD1MT2","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eFuseBox Type 2 SPD Direct to Busbar Connection Max 100A | SPD1MT2\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2\u003eCompact Type 2 Surge Protection Device for Direct Busbar Connection\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox SPD1MT2\u003c\/strong\u003e is a \u003cstrong\u003eType 2 Surge Protection Device (SPD)\u003c\/strong\u003e designed for \u003cstrong\u003edirect connection to the consumer unit busbar\u003c\/strong\u003e, providing a compact and convenient solution for protecting electrical installations against transient overvoltages.\u003c\/p\u003e\n\u003cp\u003eWith a \u003cstrong\u003emaximum current rating of 100A\u003c\/strong\u003e, the SPD1MT2 is designed to integrate neatly into compatible FuseBox consumer units without requiring a separate wired connection to the outgoing side of the main switch.\u003c\/p\u003e\n\u003cp\u003eIts direct-to-busbar configuration helps simplify installation, reduce internal wiring and provide a tidy, professional surge protection solution for modern domestic and appropriate light commercial electrical installations.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eType 2 Surge Protection Device\u003c\/li\u003e\n\u003cli\u003eDirect-to-Busbar Connection\u003c\/li\u003e\n\u003cli\u003eMaximum 100A Rating\u003c\/li\u003e\n\u003cli\u003eDesigned for Compatible FuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eHelps Protect Against Transient Overvoltages\u003c\/li\u003e\n\u003cli\u003eCompact Consumer Unit Installation\u003c\/li\u003e\n\u003cli\u003eReduces Additional Internal Wiring\u003c\/li\u003e\n\u003cli\u003eDIN Rail Mounted\u003c\/li\u003e\n\u003cli\u003eReplaceable SPD Cartridge\u003c\/li\u003e\n\u003cli\u003eVisual Status Indication\u003c\/li\u003e\n\u003cli\u003eSuitable for Single-Phase Installations\u003c\/li\u003e\n\u003cli\u003eIdeal for New Consumer Units \u0026amp; Upgrades\u003c\/li\u003e\n\u003cli\u003eDesigned for Professional Electrical Installation\u003c\/li\u003e\n\u003cli\u003ePart of the FuseBox Circuit Protection Range\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eType 2 Surge Protection\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox SPD1MT2\u003c\/strong\u003e provides \u003cstrong\u003eType 2 surge protection\u003c\/strong\u003e, helping protect the electrical installation and connected equipment against transient overvoltages.\u003c\/p\u003e\n\u003cp\u003eTransient surges can arise from events such as switching operations and indirect lightning effects. An SPD provides a controlled path for surge energy, helping limit the voltage reaching equipment connected downstream.\u003c\/p\u003e\n\u003cp\u003eThis makes surge protection increasingly important in modern properties containing sensitive electronic equipment, appliances, controls, communications equipment and smart-home technology.\u003c\/p\u003e\n\u003ch2\u003eDirect Busbar Connection\u003c\/h2\u003e\n\u003cp\u003eA key feature of the SPD1MT2 is its \u003cstrong\u003edirect-to-busbar design\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eRather than relying on additional cable connections between the main switch and SPD, the device is designed to connect directly to the busbar arrangement in compatible FuseBox consumer units.\u003c\/p\u003e\n\u003cp\u003eThis helps provide:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFaster Installation\u003c\/li\u003e\n\u003cli\u003eReduced Internal Wiring\u003c\/li\u003e\n\u003cli\u003eNeater Consumer Unit Layout\u003c\/li\u003e\n\u003cli\u003eShorter Connection Arrangement\u003c\/li\u003e\n\u003cli\u003eProfessional Finished Installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe design makes the SPD1MT2 particularly convenient when building or upgrading compatible FuseBox consumer units.\u003c\/p\u003e\n\u003ch2\u003eMaximum 100A Rating\u003c\/h2\u003e\n\u003cp\u003eThe SPD1MT2 is designed for installations with a \u003cstrong\u003emaximum rating of 100A\u003c\/strong\u003e, making it suitable for many standard domestic single-phase electrical distribution applications when correctly selected and installed.\u003c\/p\u003e\n\u003cp\u003eThe device should be matched to the consumer unit and overall installation requirements by a suitably qualified electrical installer.\u003c\/p\u003e\n\u003ch2\u003eVisual SPD Status Indication\u003c\/h2\u003e\n\u003cp\u003eThe FuseBox SPD1MT2 incorporates \u003cstrong\u003evisual status indication\u003c\/strong\u003e, allowing the operational condition of the surge protection cartridge to be checked quickly during inspection and maintenance.\u003c\/p\u003e\n\u003cp\u003eThis makes it easier to identify when the SPD cartridge requires replacement following degradation or end of service life.\u003c\/p\u003e\n\u003ch2\u003eReplaceable Surge Protection Cartridge\u003c\/h2\u003e\n\u003cp\u003eThe SPD is designed with a \u003cstrong\u003ereplaceable cartridge\u003c\/strong\u003e, allowing the surge protection element to be replaced without necessarily replacing the complete assembly.\u003c\/p\u003e\n\u003cp\u003eThis provides a practical long-term maintenance solution for installations where the SPD reaches the end of its operational life.\u003c\/p\u003e\n\u003ch2\u003eCompact Consumer Unit Protection\u003c\/h2\u003e\n\u003cp\u003eBy integrating directly with compatible FuseBox equipment, the SPD1MT2 provides surge protection without requiring a separate external enclosure.\u003c\/p\u003e\n\u003cp\u003eIts compact format makes it ideal for new consumer unit installations as well as appropriate upgrades where Type 2 surge protection needs to be incorporated into the distribution board.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e FuseBox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Code:\u003c\/strong\u003e SPD1MT2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Surge Protection Device\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSPD Classification:\u003c\/strong\u003e Type 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Type:\u003c\/strong\u003e Single Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type:\u003c\/strong\u003e Direct to Busbar\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Current Rating:\u003c\/strong\u003e 100A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN Rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSPD Cartridge:\u003c\/strong\u003e Replaceable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Indicator:\u003c\/strong\u003e Visual\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Consumer Unit Surge Protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Compatible FuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Function:\u003c\/strong\u003e Transient Overvoltage Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eDomestic Electrical Installations\u003c\/li\u003e\n\u003cli\u003eSingle-Phase Electrical Installations\u003c\/li\u003e\n\u003cli\u003eConsumer Unit Replacements\u003c\/li\u003e\n\u003cli\u003eConsumer Unit Upgrades\u003c\/li\u003e\n\u003cli\u003eNew-Build Properties\u003c\/li\u003e\n\u003cli\u003eResidential Electrical Distribution\u003c\/li\u003e\n\u003cli\u003eInstallations Requiring Type 2 Surge Protection\u003c\/li\u003e\n\u003cli\u003eProtection of Sensitive Electronic Equipment\u003c\/li\u003e\n\u003cli\u003eSmart-Home Installations\u003c\/li\u003e\n\u003cli\u003eAppropriate Light Commercial Installations\u003c\/li\u003e\n\u003cli\u003eInstallations up to 100A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose the FuseBox SPD1MT2?\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox SPD1MT2\u003c\/strong\u003e provides an installer-friendly way to add \u003cstrong\u003eType 2 surge protection\u003c\/strong\u003e to compatible FuseBox consumer units.\u003c\/p\u003e\n\u003cp\u003eIts key advantage is the \u003cstrong\u003edirect-to-busbar connection\u003c\/strong\u003e, helping reduce additional wiring and maintain a clean internal consumer unit layout. With support for installations up to \u003cstrong\u003e100A\u003c\/strong\u003e, it is particularly suited to modern domestic electrical distribution applications.\u003c\/p\u003e\n\u003cp\u003eThe combination of \u003cstrong\u003eType 2 protection, replaceable cartridge, visual status indication and direct busbar connectivity\u003c\/strong\u003e makes the SPD1MT2 a practical choice for new FuseBox consumer unit installations and appropriate electrical upgrades.\u003c\/p\u003e","brand":"FuseBox Consumer Units \u0026 Circuit Protection","offers":[{"title":"Default Title","offer_id":54694599688538,"sku":"SPD1MT2","price":27.68,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/SPD_1_MT_2_59e73eaa09.webp?v=1788441059"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/collections\/fuseboxbanner1_dda1e9f5-ed26-43df-8297-b693b00f9874.png?v=1788432835","url":"https:\/\/account.alertelectrical.com\/collections\/fusebox-rcbos-mcbs-circuit-protection.oembed","provider":"Alert Electrical","version":"1.0","type":"link"}