{"title":"PV-Ultra® Core Double Insulated Multicore DC Cable","description":"\u003cp class=\"MsoNormal\"\u003ePV-Ultra® Double Insulated Multicore DC Cable is purpose-designed for solar PV DC installations, delivering a safe, compliant, and long-life solution for DC interconnections between solar panels, DC isolators, and inverters. Engineered specifically for the DC side of photovoltaic systems, this specialist PV cable replaces older multicore armoured DC cable methods that are no longer recommended under current installation guidance.\u003c\/p\u003e","products":[{"product_id":"pv-ultra®-4mm-2-core-double-insulated-multicore-dc-cable-pv-ultra2c4-0","title":"PV-Ultra® 4mm² 2 Core Double Insulated Multicore DC Cable | PV-ULTRA2C4.0","description":"\u003ch1 class=\"MsoNormal\"\u003ePV-Ultra® 4mm² 2 Core Double Insulated Multicore DC Cable | PV-ULTRA2C4.0\u003c\/h1\u003e\n\u003cp class=\"MsoNormal\"\u003ePV-Ultra® 4mm² 2 Core Double Insulated Multicore DC Cable is purpose-designed for photovoltaic (solar PV) DC installations, providing a safe, compliant and durable solution for DC interconnections between solar panels, DC isolators and inverters.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003ePlease Note: PV-Ultra® Cable is sold per meter \u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eDeveloped specifically for the DC side of PV systems, PV-Ultra® replaces older multicore armoured approaches that are no longer recommended. With double insulated conductors, high mechanical strength and UV-stable outer sheath, it is suitable for both internal and external installation and is engineered for a service life of around 25 years.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eFeatures\u003c\/h2\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eDesigned for Solar PV DC Systems\u003c\/li\u003e\n\u003cli style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e4mm² 2 Core Multicore DC Cable\u003c\/li\u003e\n\u003cli style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eDouble Insulated Conductors – Suitable for Class II equipment\u003c\/li\u003e\n\u003cli style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eRated up to 1.5kV DC (conductor-to-conductor \u0026amp; to earth)\u003c\/li\u003e\n\u003cli style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eDirect Replacement for Multicore Armoured DC Cables\u003c\/li\u003e\n\u003cli style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eSuitable for Internal \u0026amp; External Use\u003c\/li\u003e\n\u003cli style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eExcellent Mechanical Properties\u003c\/li\u003e\n\u003cli style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eRed \u0026amp; White Core Colours – BS 7671 compliant identification\u003c\/li\u003e\n\u003cli style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eYellow DC Warning Print – Indicates live during daylight hours\u003c\/li\u003e\n\u003cli style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eLong Design Life – Approx. 25 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"MsoNormal\"\u003eCompliance \u0026amp; Safety\u003c\/h2\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eDesigned for PV DC interconnections\u003c\/li\u003e\n\u003cli style=\"mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eMeets BS 7671 requirements for two-wire unearthed DC circuits\u003c\/li\u003e\n\u003cli style=\"mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eSupports Class II or equivalent insulation up to inverter DC connection\u003c\/li\u003e\n\u003cli style=\"mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eComplies with BS 7671 Clause 712.412.101\u003c\/li\u003e\n\u003cli style=\"mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eAvoids use of DC multicore armoured cable (no longer recommended)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"MsoNormal\"\u003eConstruction\u003c\/h2\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eConductors: Double insulated DC cores\u003c\/li\u003e\n\u003cli style=\"mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eCore Colours: Red \u0026amp; White (DC identification compliant)\u003c\/li\u003e\n\u003cli style=\"mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eBedding: CarbonTek® – enhanced electrical protection\u003c\/li\u003e\n\u003cli style=\"mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eOuter Sheath: SolarTek® PVC\u003c\/li\u003e\n\u003cli style=\"mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eMarking: Yellow warning print for DC hazard visibility\u003c\/li\u003e\n\u003cli style=\"mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eAppearance: Similar to mains cable to reduce accidental misidentification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermal Performance\u003c\/h2\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l1 level1 lfo4; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eNormal Max Conductor Temperature: 90°C\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo4; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eShort-Term Max Conductor Temperature: 120°C\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo4; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eMax Duration at 120°C: Up to 20,000 hours\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo4; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eMax Ambient (short-term): 90°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"MsoNormal\"\u003eTypical Applications\u003c\/h2\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l0 level1 lfo5; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eSolar panel to DC isolator runs\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo5; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eDC isolator to inverter connections\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo5; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003ePV array string wiring (multicore runs)\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo5; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eSurface and internal DC routing\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo5; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eResidential \u0026amp; commercial PV installs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Doncaster Cables","offers":[{"title":"Default Title","offer_id":53607044350298,"sku":"PV-ULTRA2C4.0","price":6.12,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/6538ff55d5067_large_239a153f-09a5-4faf-8411-649308f71eb4.png?v=1771245883"},{"product_id":"pv-ultra®-6mm-2-core-double-insulated-multicore-dc-cable-pv-ultra2c6-0","title":"PV-Ultra® 6mm² 2 Core Double Insulated Multicore DC Cable | PV-ULTRA2C6.0","description":"\u003ch1 class=\"MsoNormal\"\u003ePV-Ultra® 6mm² 2 Core Double Insulated Multicore DC Cable | PV-ULTRA2C6.0\u003c\/h1\u003e\n\u003cp class=\"MsoNormal\"\u003ePV-Ultra® 6mm² 2 Core Double Insulated Multicore DC Cable is purpose-designed for photovoltaic (solar PV) DC installations, providing a safe, compliant and durable solution for DC interconnections between solar panels, DC isolators and inverters.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003ePlease Note: PV-Ultra® Cable is sold per meter \u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eDeveloped specifically for the DC side of PV systems, PV-Ultra® replaces older multicore armoured approaches that are no longer recommended. With double insulated conductors, high mechanical strength and UV-stable outer sheath, it is suitable for both internal and external installation and is engineered for a service life of around 25 years.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\"\u003eDesigned for Solar PV DC Systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\"\u003e6mm² 2 Core Multicore DC Cable\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\"\u003eDouble Insulated Conductors – Suitable for Class II equipment\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\"\u003eRated up to 1.5kV DC (conductor-to-conductor \u0026amp; to earth)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\"\u003eDirect Replacement for Multicore Armoured DC Cables\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\"\u003eSuitable for Internal \u0026amp; External Use\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\"\u003eExcellent Mechanical Properties\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\"\u003eRed \u0026amp; White Core Colours – BS 7671 compliant identification\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\"\u003eYellow DC Warning Print – Indicates live during daylight hours\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\"\u003eLong Design Life – Approx. 25 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"MsoNormal\"\u003eCompliance \u0026amp; Safety\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003eDesigned for PV DC interconnections\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003eMeets BS 7671 requirements for two-wire unearthed DC circuits\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003eSupports Class II or equivalent insulation up to inverter DC connection\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003eComplies with BS 7671 Clause 712.412.101\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003eAvoids use of DC multicore armoured cable (no longer recommended)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"MsoNormal\"\u003eConstruction\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003eConductors: Double insulated DC cores\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003eCore Colours: Red \u0026amp; White (DC identification compliant)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003eBedding: CarbonTek® – enhanced electrical protection\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003eOuter Sheath: SolarTek® PVC\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003eMarking: Yellow warning print for DC hazard visibility\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003eAppearance: Similar to mains cable to reduce accidental misidentification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermal Performance\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo4; tab-stops: list 36.0pt;\"\u003eNormal Max Conductor Temperature: 90°C\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo4; tab-stops: list 36.0pt;\"\u003eShort-Term Max Conductor Temperature: 120°C\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo4; tab-stops: list 36.0pt;\"\u003eMax Duration at 120°C: Up to 20,000 hours\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo4; tab-stops: list 36.0pt;\"\u003eMax Ambient (short-term): 90°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"MsoNormal\"\u003eTypical Applications\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo5; tab-stops: list 36.0pt;\"\u003eSolar panel to DC isolator runs\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo5; tab-stops: list 36.0pt;\"\u003eDC isolator to inverter connections\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo5; tab-stops: list 36.0pt;\"\u003ePV array string wiring (multicore runs)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo5; tab-stops: list 36.0pt;\"\u003eSurface and internal DC routing\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo5; tab-stops: list 36.0pt;\"\u003eResidential \u0026amp; commercial PV installs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Doncaster Cables","offers":[{"title":"Default Title","offer_id":53607067844954,"sku":"PV-ULTRA2C6.0","price":7.47,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/6538ff55d5067_large_239a153f-09a5-4faf-8411-649308f71eb4.png?v=1771245883"},{"product_id":"pv-ultra®-4mm-4-core-double-insulated-multicore-dc-cable-pv-ultra4c4-0","title":"PV-Ultra® 4mm² 4 Core Double Insulated Multicore DC Cable | PV-ULTRA4C4.0","description":"\u003ch1 class=\"MsoNormal\"\u003ePV-Ultra® 4mm² 4 Core Double Insulated Multicore DC Cable | PV-ULTRA4C4.0\u003c\/h1\u003e\n\u003cp class=\"MsoNormal\"\u003ePV-Ultra® 4mm² 4 Core Double Insulated Multicore DC Cable is purpose-designed for photovoltaic (solar PV) DC installations, providing a safe, compliant and durable solution for DC interconnections between solar panels, DC isolators and inverters.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003ePlease Note: PV-Ultra® Cable is sold per meter \u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eDeveloped specifically for the DC side of PV systems, PV-Ultra® replaces older multicore armoured approaches that are no longer recommended. With double insulated conductors, high mechanical strength and UV-stable outer sheath, it is suitable for both internal and external installation and is engineered for a service life of around 25 years.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\"\u003eDesigned for Solar PV DC Systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\"\u003e4mm² 4 Core Multicore DC Cable\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\"\u003eDouble Insulated Conductors – Suitable for Class II equipment\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\"\u003eRated up to 1.5kV DC (conductor-to-conductor \u0026amp; to earth)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\"\u003eDirect Replacement for Multicore Armoured DC Cables\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\"\u003eSuitable for Internal \u0026amp; External Use\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\"\u003eExcellent Mechanical Properties\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\"\u003eRed \u0026amp; White Core Colours – BS 7671 compliant identification\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\"\u003eYellow DC Warning Print – Indicates live during daylight hours\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\"\u003eLong Design Life – Approx. 25 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"MsoNormal\"\u003eCompliance \u0026amp; Safety\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003eDesigned for PV DC interconnections\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003eMeets BS 7671 requirements for two-wire unearthed DC circuits\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003eSupports Class II or equivalent insulation up to inverter DC connection\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003eComplies with BS 7671 Clause 712.412.101\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003eAvoids use of DC multicore armoured cable (no longer recommended)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"MsoNormal\"\u003eConstruction\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003eConductors: Double insulated DC cores\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003eCore Colours: Red \u0026amp; White (DC identification compliant)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003eBedding: CarbonTek® – enhanced electrical protection\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003eOuter Sheath: SolarTek® PVC\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003eMarking: Yellow warning print for DC hazard visibility\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003eAppearance: Similar to mains cable to reduce accidental misidentification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermal Performance\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo4; tab-stops: list 36.0pt;\"\u003eNormal Max Conductor Temperature: 90°C\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo4; tab-stops: list 36.0pt;\"\u003eShort-Term Max Conductor Temperature: 120°C\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo4; tab-stops: list 36.0pt;\"\u003eMax Duration at 120°C: Up to 20,000 hours\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo4; tab-stops: list 36.0pt;\"\u003eMax Ambient (short-term): 90°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"MsoNormal\"\u003eTypical Applications\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo5; tab-stops: list 36.0pt;\"\u003eSolar panel to DC isolator runs\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo5; tab-stops: list 36.0pt;\"\u003eDC isolator to inverter connections\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo5; tab-stops: list 36.0pt;\"\u003ePV array string wiring (multicore runs)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo5; tab-stops: list 36.0pt;\"\u003eSurface and internal DC routing\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo5; tab-stops: list 36.0pt;\"\u003eResidential \u0026amp; commercial PV installs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Doncaster Cables","offers":[{"title":"Default Title","offer_id":53607097991514,"sku":"PV-ULTRA4C4.0","price":8.73,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/6538ff55d5067_large_239a153f-09a5-4faf-8411-649308f71eb4.png?v=1771245883"},{"product_id":"pv-ultra®-6mm-4-core-double-insulated-multicore-dc-cable-pv-ultra4c6-0","title":"PV-Ultra® 6mm² 4 Core Double Insulated Multicore DC Cable | PV-ULTRA4C6.0","description":"\u003ch1 class=\"MsoNormal\"\u003ePV-Ultra® 6mm² 4 Core Double Insulated Multicore DC Cable | PV-ULTRA4C6.0\u003c\/h1\u003e\n\u003cp class=\"MsoNormal\"\u003ePV-Ultra® 6mm² 4 Core Double Insulated Multicore DC Cable is purpose-designed for photovoltaic (solar PV) DC installations, providing a safe, compliant and durable solution for DC interconnections between solar panels, DC isolators and inverters.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003ePlease Note: PV-Ultra® Cable is sold per meter \u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eDeveloped specifically for the DC side of PV systems, PV-Ultra® replaces older multicore armoured approaches that are no longer recommended. With double insulated conductors, high mechanical strength and UV-stable outer sheath, it is suitable for both internal and external installation and is engineered for a service life of around 25 years.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eFeatures\u003c\/h2\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eDesigned for Solar PV DC Systems\u003c\/li\u003e\n\u003cli style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e6mm² 4 Core Multicore DC Cable\u003c\/li\u003e\n\u003cli style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eDouble Insulated Conductors – Suitable for Class II equipment\u003c\/li\u003e\n\u003cli style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eRated up to 1.5kV DC (conductor-to-conductor \u0026amp; to earth)\u003c\/li\u003e\n\u003cli style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eDirect Replacement for Multicore Armoured DC Cables\u003c\/li\u003e\n\u003cli style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eSuitable for Internal \u0026amp; External Use\u003c\/li\u003e\n\u003cli style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eExcellent Mechanical Properties\u003c\/li\u003e\n\u003cli style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eRed \u0026amp; White Core Colours – BS 7671 compliant identification\u003c\/li\u003e\n\u003cli style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eYellow DC Warning Print – Indicates live during daylight hours\u003c\/li\u003e\n\u003cli style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eLong Design Life – Approx. 25 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"MsoNormal\"\u003eCompliance \u0026amp; Safety\u003c\/h2\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eDesigned for PV DC interconnections\u003c\/li\u003e\n\u003cli style=\"mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eMeets BS 7671 requirements for two-wire unearthed DC circuits\u003c\/li\u003e\n\u003cli style=\"mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eSupports Class II or equivalent insulation up to inverter DC connection\u003c\/li\u003e\n\u003cli style=\"mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eComplies with BS 7671 Clause 712.412.101\u003c\/li\u003e\n\u003cli style=\"mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eAvoids use of DC multicore armoured cable (no longer recommended)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"MsoNormal\"\u003eConstruction\u003c\/h2\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eConductors: Double insulated DC cores\u003c\/li\u003e\n\u003cli style=\"mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eCore Colours: Red \u0026amp; White (DC identification compliant)\u003c\/li\u003e\n\u003cli style=\"mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eBedding: CarbonTek® – enhanced electrical protection\u003c\/li\u003e\n\u003cli style=\"mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eOuter Sheath: SolarTek® PVC\u003c\/li\u003e\n\u003cli style=\"mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eMarking: Yellow warning print for DC hazard visibility\u003c\/li\u003e\n\u003cli style=\"mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eAppearance: Similar to mains cable to reduce accidental misidentification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"MsoNormal\"\u003eThermal Performance\u003c\/h2\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l1 level1 lfo4; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eNormal Max Conductor Temperature: 90°C\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo4; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eShort-Term Max Conductor Temperature: 120°C\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo4; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eMax Duration at 120°C: Up to 20,000 hours\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo4; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eMax Ambient (short-term): 90°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"MsoNormal\"\u003eTypical Applications\u003c\/h2\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l0 level1 lfo5; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eSolar panel to DC isolator runs\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo5; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eDC isolator to inverter connections\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo5; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003ePV array string wiring (multicore runs)\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo5; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eSurface and internal DC routing\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo5; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eResidential \u0026amp; commercial PV installs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Doncaster Cables","offers":[{"title":"Default Title","offer_id":53607114408282,"sku":"PV-ULTRA4C6.0","price":10.1,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/6538ff55d5067_large_239a153f-09a5-4faf-8411-649308f71eb4.png?v=1771245883"}],"url":"https:\/\/account.alertelectrical.com\/collections\/pv-ultra%c2%ae-core-double-insulated-multicore-dc-cable.oembed","provider":"Alert Electrical","version":"1.0","type":"link"}