{"product_id":"bell-system-cs106-3-3-way-coded-door-entry-kit-surface","title":"Bell System CS106-3 3-Way Coded Door Entry Kit Surface","description":"\u003ch1 data-section-id=\"1bkj2ys\" dir=\"auto\" data-start=\"0\" data-end=\"56\"\u003eBell System CS106-3 3-Way Coded Door Entry Kit Surface\u003c\/h1\u003e\n\u003ch2 data-section-id=\"qqc4ce\" dir=\"auto\" data-start=\"58\" data-end=\"140\"\u003eCombined 3-Way Audio Door Entry \u0026amp; Coded Access System with Surface Lock Release\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"142\" data-end=\"440\"\u003eThe \u003cstrong data-start=\"146\" data-end=\"196\"\u003eBell System CS106-3 3-Way Coded Door Entry Kit\u003c\/strong\u003e combines a traditional \u003cstrong data-start=\"220\" data-end=\"288\"\u003eaudio door entry system with standalone keypad-controlled access\u003c\/strong\u003e, providing a practical entrance security solution for properties requiring communication with \u003cstrong data-start=\"383\" data-end=\"439\"\u003ethree separate users or internal telephone positions\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"442\" data-end=\"755\"\u003eDesigned as the \u003cstrong data-start=\"458\" data-end=\"507\"\u003e3-way version of the Bell System CS106 series\u003c\/strong\u003e, the system allows visitors at the entrance to call the required property or user and communicate with them using the supplied \u003cstrong data-start=\"635\" data-end=\"669\"\u003eBell 801 door entry telephones\u003c\/strong\u003e. The occupant can then operate the electric lock release from inside to grant access.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"757\" data-end=\"1027\"\u003eFor residents, staff and other authorised users, the integrated \u003cstrong data-start=\"821\" data-end=\"849\"\u003eC106 coded access keypad\u003c\/strong\u003e provides convenient keyless entry. The keypad can be programmed with \u003cstrong data-start=\"919\" data-end=\"951\"\u003eup to 10 unique access codes\u003c\/strong\u003e, and entering a valid code operates the lock release for a preset duration.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1029\" data-end=\"1215\"\u003eClear \u003cstrong data-start=\"1035\" data-end=\"1067\"\u003egreen and red LED indicators\u003c\/strong\u003e provide immediate feedback at the keypad. The green LED indicates that the lock release is operating, while the red LED indicates an invalid entry.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1217\" data-end=\"1563\"\u003eSupplied as a complete system with \u003cstrong data-start=\"1252\" data-end=\"1409\"\u003ethree 801 telephones, an aluminium entrance panel with coded keypad, model 61 speech unit, PS4A 12V 4A DC power supply and model 203 surface lock release\u003c\/strong\u003e, the CS106-3 is ideal for small multi-occupancy residential and commercial applications where a straightforward level of door-entry security is required.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" dir=\"auto\" data-start=\"1565\" data-end=\"1580\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1582\" data-end=\"2392\"\u003e\n\u003cli data-section-id=\"1mp8dm8\" data-start=\"1582\" data-end=\"1634\"\u003eBell System Combined Door Entry \u0026amp; Coded Access Kit\u003c\/li\u003e\n\u003cli data-section-id=\"pgwjdj\" data-start=\"1635\" data-end=\"1657\"\u003eProduct Code CS106-3\u003c\/li\u003e\n\u003cli data-section-id=\"1h54w9q\" data-start=\"1658\" data-end=\"1683\"\u003e3-Way Door Entry System\u003c\/li\u003e\n\u003cli data-section-id=\"1vwyb9n\" data-start=\"1684\" data-end=\"1727\"\u003eDesigned for Three Users \/ Call Positions\u003c\/li\u003e\n\u003cli data-section-id=\"t4wrhk\" data-start=\"1728\" data-end=\"1764\"\u003eThree Bell 801 Internal Telephones\u003c\/li\u003e\n\u003cli data-section-id=\"i0b95x\" data-start=\"1765\" data-end=\"1797\"\u003eStandalone Coded Access System\u003c\/li\u003e\n\u003cli data-section-id=\"gafv9p\" data-start=\"1798\" data-end=\"1827\"\u003eSurface-Mount Configuration\u003c\/li\u003e\n\u003cli data-section-id=\"17yn3sm\" data-start=\"1828\" data-end=\"1856\"\u003eAudio Speech Communication\u003c\/li\u003e\n\u003cli data-section-id=\"1biwqk0\" data-start=\"1857\" data-end=\"1889\"\u003eIntegrated Coded Access Keypad\u003c\/li\u003e\n\u003cli data-section-id=\"o4gj67\" data-start=\"1890\" data-end=\"1925\"\u003eUp to 10 Unique User Access Codes\u003c\/li\u003e\n\u003cli data-section-id=\"c73ztz\" data-start=\"1926\" data-end=\"1962\"\u003eProgrammable Lock Release Duration\u003c\/li\u003e\n\u003cli data-section-id=\"6gbc94\" data-start=\"1963\" data-end=\"1994\"\u003eGreen Lock Release Status LED\u003c\/li\u003e\n\u003cli data-section-id=\"115bkhq\" data-start=\"1995\" data-end=\"2018\"\u003eRed Invalid-Entry LED\u003c\/li\u003e\n\u003cli data-section-id=\"rbisgf\" data-start=\"2019\" data-end=\"2050\"\u003eAluminium Entrance Door Panel\u003c\/li\u003e\n\u003cli data-section-id=\"1yqpt2e\" data-start=\"2051\" data-end=\"2072\"\u003eBell 61 Speech Unit\u003c\/li\u003e\n\u003cli data-section-id=\"1gjfnsi\" data-start=\"2073\" data-end=\"2107\"\u003eBell PS4A 12V 4A DC Power Supply\u003c\/li\u003e\n\u003cli data-section-id=\"18tovmx\" data-start=\"2108\" data-end=\"2139\"\u003eBell 203 Surface Lock Release\u003c\/li\u003e\n\u003cli data-section-id=\"mktrxz\" data-start=\"2140\" data-end=\"2171\"\u003eInternal Door Release Control\u003c\/li\u003e\n\u003cli data-section-id=\"fes42d\" data-start=\"2172\" data-end=\"2208\"\u003eKeyless Entry for Authorised Users\u003c\/li\u003e\n\u003cli data-section-id=\"azhk7h\" data-start=\"2209\" data-end=\"2244\"\u003eVisitor Calling \u0026amp; Speech Facility\u003c\/li\u003e\n\u003cli data-section-id=\"1coe96b\" data-start=\"2245\" data-end=\"2291\"\u003eFull Installation \u0026amp; Programming Instructions\u003c\/li\u003e\n\u003cli data-section-id=\"1m7ovdz\" data-start=\"2292\" data-end=\"2339\"\u003eSuitable for Small Multi-Occupancy Properties\u003c\/li\u003e\n\u003cli data-section-id=\"117ebwj\" data-start=\"2340\" data-end=\"2392\"\u003eSuitable for Residential \u0026amp; Commercial Applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"s9s5yr\" dir=\"auto\" data-start=\"2394\" data-end=\"2420\"\u003e3-Way Door Entry System\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"2422\" data-end=\"2581\"\u003eThe \u003cstrong data-start=\"2426\" data-end=\"2469\"\u003eCS106-3 is configured as a 3-way system\u003c\/strong\u003e, making it suitable for an entrance serving three individual users, properties or internal telephone positions.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2583\" data-end=\"2716\"\u003eThe external panel provides the visitor calling point, while each internal position is equipped with a \u003cstrong data-start=\"2686\" data-end=\"2715\"\u003eBell System 801 telephone\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2718\" data-end=\"2902\"\u003eThis arrangement makes the CS106-3 particularly useful for small converted properties, three-unit buildings and commercial premises where a common entrance serves three separate users.\u003c\/p\u003e\n\u003ch2 data-section-id=\"2cux0p\" dir=\"auto\" data-start=\"2904\" data-end=\"2941\"\u003eCombined Door Entry \u0026amp; Coded Access\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"2943\" data-end=\"3082\"\u003eRather than requiring separate systems for visitors and regular users, the CS106-3 combines \u003cstrong data-start=\"3035\" data-end=\"3081\"\u003eaudio door entry and keypad access control\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3084\" data-end=\"3280\"\u003eVisitors can call the appropriate occupant from the external entrance panel. The occupant can communicate with the visitor using their internal handset before deciding whether to release the door.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3282\" data-end=\"3448\"\u003eAuthorised residents or staff can instead enter a valid code directly on the keypad, providing convenient access without first calling one of the internal telephones.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1s01134\" dir=\"auto\" data-start=\"3450\" data-end=\"3489\"\u003eThree Bell 801 Door Entry Telephones\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"3491\" data-end=\"3569\"\u003eThe CS106-3 configuration includes \u003cstrong data-start=\"3526\" data-end=\"3568\"\u003ethree Bell System model 801 telephones\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3571\" data-end=\"3665\"\u003eEach handset provides an internal audio point for communication with visitors at the entrance.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3667\" data-end=\"3852\"\u003eThis allows three separate users or locations to be connected to the common entrance system, with occupants able to identify visitors through voice communication before granting access.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1gxcyr8\" dir=\"auto\" data-start=\"3854\" data-end=\"3893\"\u003eAluminium Entrance Panel with Keypad\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"3895\" data-end=\"3989\"\u003eThe system incorporates a \u003cstrong data-start=\"3921\" data-end=\"3988\"\u003eCP106-series aluminium door panel with integrated keypad module\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3991\" data-end=\"4218\"\u003eCombining the call facilities and coded access keypad into one entrance panel provides a neat and professional solution while avoiding the need to install a completely separate access-control keypad beside the door-entry panel.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4220\" data-end=\"4328\"\u003eThe aluminium construction provides a durable and smart appearance suitable for a wide variety of entrances.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1s8evhv\" dir=\"auto\" data-start=\"4330\" data-end=\"4361\"\u003eUp to 10 Unique Access Codes\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"4363\" data-end=\"4433\"\u003eThe \u003cstrong data-start=\"4367\" data-end=\"4432\"\u003eC106 coded keypad can store up to 10 unique user access codes\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4435\" data-end=\"4542\"\u003eThis gives installers and property managers flexibility when providing access to multiple authorised users.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4544\" data-end=\"4695\"\u003eCodes can potentially be allocated to different residents, members of staff or other approved users, depending on the requirements of the installation.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4697\" data-end=\"4807\"\u003eThis is particularly useful in a three-user property because the keypad is not restricted to just three codes.\u003c\/p\u003e\n\u003ch2 data-section-id=\"17acffc\" dir=\"auto\" data-start=\"4809\" data-end=\"4846\"\u003eKeyless Entry for Authorised Users\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"4848\" data-end=\"4968\"\u003eThe keypad gives authorised users a convenient method of entering the property without relying solely on a physical key.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4970\" data-end=\"5072\"\u003eWhen a valid code is entered, the system operates the electric lock release for the programmed period.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5074\" data-end=\"5182\"\u003eThis makes the CS106-3 useful where residents or employees require regular access through a shared entrance.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1r705t6\" dir=\"auto\" data-start=\"5184\" data-end=\"5221\"\u003eProgrammable Lock Release Duration\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"5223\" data-end=\"5320\"\u003eThe lock release operates for a \u003cstrong data-start=\"5255\" data-end=\"5287\"\u003epreset programmable duration\u003c\/strong\u003e following successful code entry.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5322\" data-end=\"5453\"\u003eThis provides sufficient time for an authorised user to open the door while ensuring the entrance is not left permanently released.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5455\" data-end=\"5560\"\u003eThe system can therefore be configured according to the practical requirements of the particular doorway.\u003c\/p\u003e\n\u003ch2 data-section-id=\"ui90u8\" dir=\"auto\" data-start=\"5562\" data-end=\"5598\"\u003eRed \u0026amp; Green LED Status Indicators\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"5600\" data-end=\"5688\"\u003eThe C106 keypad incorporates simple visual indication to make operation straightforward.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5690\" data-end=\"5831\"\u003eThe \u003cstrong data-start=\"5694\" data-end=\"5766\"\u003egreen LED illuminates to indicate that the lock release is operating\u003c\/strong\u003e, providing confirmation that the entered code has been accepted.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5833\" data-end=\"5948\"\u003eThe \u003cstrong data-start=\"5837\" data-end=\"5875\"\u003ered LED indicates an invalid entry\u003c\/strong\u003e, immediately informing the user when an incorrect code has been entered.\u003c\/p\u003e\n\u003ch2 data-section-id=\"svt9vv\" dir=\"auto\" data-start=\"5950\" data-end=\"5972\"\u003eBell 61 Speech Unit\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"5974\" data-end=\"6146\"\u003eThe system includes a \u003cstrong data-start=\"5996\" data-end=\"6032\"\u003eBell System model 61 speech unit\u003c\/strong\u003e, forming part of the audio communication arrangement between the external entrance panel and internal telephones.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"6148\" data-end=\"6316\"\u003eThis allows visitors and occupants to communicate before access is granted, providing the essential speech functionality expected from an audio door-entry installation.\u003c\/p\u003e\n\u003ch2 data-section-id=\"3d40o\" dir=\"auto\" data-start=\"6318\" data-end=\"6348\"\u003ePS4A 12V 4A DC Power Supply\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"6350\" data-end=\"6424\"\u003eA \u003cstrong data-start=\"6352\" data-end=\"6395\"\u003eBell System PS4A 12V 4A DC power supply\u003c\/strong\u003e is included with the system.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"6426\" data-end=\"6545\"\u003eThe power supply provides the low-voltage DC power required for the compatible door-entry and access-control equipment.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"6547\" data-end=\"6708\"\u003eIncluding the appropriate power supply within the kit simplifies specification and helps ensure installers have the principal components required for the system.\u003c\/p\u003e\n\u003ch2 data-section-id=\"2u8tr0\" dir=\"auto\" data-start=\"6710\" data-end=\"6751\"\u003eBell 203 Surface Lock Release Included\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"6753\" data-end=\"6831\"\u003eThe CS106-3 is supplied with a \u003cstrong data-start=\"6784\" data-end=\"6830\"\u003eBell System model 203 surface lock release\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"6833\" data-end=\"6992\"\u003eThe electric release enables the entrance door to be unlocked either following an authorised keypad entry or when access is granted from an internal telephone.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"6994\" data-end=\"7128\"\u003eThe inclusion of the surface release makes this kit particularly convenient for entrances suited to this style of locking arrangement.\u003c\/p\u003e\n\u003ch2 data-section-id=\"xbr4fu\" dir=\"auto\" data-start=\"7130\" data-end=\"7157\"\u003eVisitor-Controlled Entry\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"7159\" data-end=\"7236\"\u003eFor visitors, the CS106-3 operates as a conventional audio door-entry system.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"7238\" data-end=\"7327\"\u003eA caller selects the appropriate call position at the entrance and contacts the occupant.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"7329\" data-end=\"7414\"\u003eThe occupant can then speak with the visitor before choosing whether to grant access.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"7416\" data-end=\"7515\"\u003eThis provides a straightforward method of controlling visitor entry to a small multi-user building.\u003c\/p\u003e\n\u003ch2 data-section-id=\"la2kdi\" dir=\"auto\" data-start=\"7517\" data-end=\"7553\"\u003eCoded Entry for Residents \u0026amp; Staff\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"7555\" data-end=\"7628\"\u003eRegular authorised users do not need to use the visitor calling function.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"7630\" data-end=\"7744\"\u003eInstead, they can enter their programmed access code at the entrance keypad and operate the lock release directly.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"7746\" data-end=\"7837\"\u003eThis combination makes the system convenient for both visitors and everyday building users.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1hb9hgt\" dir=\"auto\" data-start=\"7839\" data-end=\"7865\"\u003eStandalone Coded Access\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"7867\" data-end=\"7968\"\u003eThe coded-access element of the CS106 system is designed as a \u003cstrong data-start=\"7929\" data-end=\"7967\"\u003estandalone access-control solution\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"7970\" data-end=\"8085\"\u003eIt provides straightforward local keypad access without requiring a more complex networked access-control platform.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"8087\" data-end=\"8292\"\u003eThe CS106 series is intended for installations where a \u003cstrong data-start=\"8142\" data-end=\"8192\"\u003ebasic level of security is considered adequate\u003c\/strong\u003e, making it particularly suitable for straightforward residential and light-commercial applications.\u003c\/p\u003e\n\u003ch2 data-section-id=\"us0c2m\" dir=\"auto\" data-start=\"8294\" data-end=\"8339\"\u003eIdeal for Small Multi-Occupancy Properties\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"8341\" data-end=\"8467\"\u003eThe three-way configuration makes the CS106-3 particularly useful for properties containing three separate occupants or units.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"8469\" data-end=\"8498\"\u003eTypical examples can include:\u003c\/p\u003e\n\u003cul data-start=\"8500\" data-end=\"8695\"\u003e\n\u003cli data-section-id=\"1riz9en\" data-start=\"8500\" data-end=\"8524\"\u003eThree-Flat Conversions\u003c\/li\u003e\n\u003cli data-section-id=\"ds9l1y\" data-start=\"8525\" data-end=\"8552\"\u003eSmall Apartment Buildings\u003c\/li\u003e\n\u003cli data-section-id=\"wtrif2\" data-start=\"8553\" data-end=\"8588\"\u003eThree-Unit Residential Properties\u003c\/li\u003e\n\u003cli data-section-id=\"25i11g\" data-start=\"8589\" data-end=\"8619\"\u003eShared Residential Entrances\u003c\/li\u003e\n\u003cli data-section-id=\"1vun4zt\" data-start=\"8620\" data-end=\"8653\"\u003eSmall Multi-Occupancy Buildings\u003c\/li\u003e\n\u003cli data-section-id=\"zjl463\" data-start=\"8654\" data-end=\"8695\"\u003eMixed Residential \u0026amp; Commercial Premises\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"8697\" data-end=\"8814\"\u003eEach user benefits from an individual internal telephone while sharing the common entrance and coded-access facility.\u003c\/p\u003e\n\u003ch2 data-section-id=\"pvcqx6\" dir=\"auto\" data-start=\"8816\" data-end=\"8857\"\u003eSuitable for Small Commercial Premises\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"8859\" data-end=\"8997\"\u003eThe CS106-3 can also be used where a common entrance needs to communicate with three internal areas or users within a commercial property.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"8999\" data-end=\"9100\"\u003ePotential applications include small office buildings, workshops and other light-commercial premises.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"9102\" data-end=\"9229\"\u003eThe coded keypad can provide regular staff with convenient access while visitors continue to use the door-entry calling system.\u003c\/p\u003e\n\u003ch2 data-section-id=\"16h56xk\" dir=\"auto\" data-start=\"9231\" data-end=\"9257\"\u003eComplete Door Entry Kit\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"9259\" data-end=\"9367\"\u003eThe CS106-3 brings together the principal components required for a three-way coded door-entry installation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"7kf8h6\" dir=\"auto\" data-start=\"9369\" data-end=\"9385\"\u003eKit Contents\u003c\/h3\u003e\n\u003cul data-start=\"9387\" data-end=\"9703\"\u003e\n\u003cli data-section-id=\"165amtp\" data-start=\"9387\" data-end=\"9434\"\u003e\u003cstrong data-start=\"9389\" data-end=\"9434\"\u003e3 x Bell System 801 Door Entry Telephones\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1gftac4\" data-start=\"9435\" data-end=\"9496\"\u003e\u003cstrong data-start=\"9437\" data-end=\"9496\"\u003e1 x CP106 Series Aluminium Door Panel with Coded Keypad\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1cqrbje\" data-start=\"9497\" data-end=\"9533\"\u003e\u003cstrong data-start=\"9499\" data-end=\"9533\"\u003e1 x Bell System 61 Speech Unit\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"6zpldq\" data-start=\"9534\" data-end=\"9583\"\u003e\u003cstrong data-start=\"9536\" data-end=\"9583\"\u003e1 x Bell System PS4A 12V 4A DC Power Supply\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"k18w9x\" data-start=\"9584\" data-end=\"9630\"\u003e\u003cstrong data-start=\"9586\" data-end=\"9630\"\u003e1 x Bell System 203 Surface Lock Release\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1fipoy4\" data-start=\"9631\" data-end=\"9667\"\u003e\u003cstrong data-start=\"9633\" data-end=\"9667\"\u003eFull Installation Instructions\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"16ukp5\" data-start=\"9668\" data-end=\"9703\"\u003e\u003cstrong data-start=\"9670\" data-end=\"9703\"\u003eFull Programming Instructions\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"9705\" data-end=\"9850\"\u003eProviding these core components as a single kit simplifies specification for installers compared with selecting each principal item individually.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1cgu054\" dir=\"auto\" data-start=\"9852\" data-end=\"9879\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"9881\" data-end=\"10877\"\u003e\n\u003cli data-section-id=\"jvy697\" data-start=\"9881\" data-end=\"9905\"\u003e\n\u003cstrong data-start=\"9883\" data-end=\"9893\"\u003eBrand:\u003c\/strong\u003e Bell System\u003c\/li\u003e\n\u003cli data-section-id=\"ifq57y\" data-start=\"9906\" data-end=\"9925\"\u003e\n\u003cstrong data-start=\"9908\" data-end=\"9919\"\u003eSeries:\u003c\/strong\u003e CS106\u003c\/li\u003e\n\u003cli data-section-id=\"19h2nhp\" data-start=\"9926\" data-end=\"9953\"\u003e\n\u003cstrong data-start=\"9928\" data-end=\"9945\"\u003eProduct Code:\u003c\/strong\u003e CS106-3\u003c\/li\u003e\n\u003cli data-section-id=\"91g34d\" data-start=\"9954\" data-end=\"10018\"\u003e\n\u003cstrong data-start=\"9956\" data-end=\"9973\"\u003eProduct Type:\u003c\/strong\u003e Combined Audio Door Entry \u0026amp; Coded Access Kit\u003c\/li\u003e\n\u003cli data-section-id=\"18vf4m\" data-start=\"10019\" data-end=\"10052\"\u003e\n\u003cstrong data-start=\"10021\" data-end=\"10046\"\u003eSystem Configuration:\u003c\/strong\u003e 3-Way\u003c\/li\u003e\n\u003cli data-section-id=\"1r04trv\" data-start=\"10053\" data-end=\"10091\"\u003e\n\u003cstrong data-start=\"10055\" data-end=\"10089\"\u003eNumber of Internal Telephones:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli data-section-id=\"mt9ogw\" data-start=\"10092\" data-end=\"10132\"\u003e\n\u003cstrong data-start=\"10094\" data-end=\"10123\"\u003eInternal Telephone Model:\u003c\/strong\u003e Bell 801\u003c\/li\u003e\n\u003cli data-section-id=\"1r5s1aq\" data-start=\"10133\" data-end=\"10161\"\u003e\n\u003cstrong data-start=\"10135\" data-end=\"10153\"\u003eMounting Type:\u003c\/strong\u003e Surface\u003c\/li\u003e\n\u003cli data-section-id=\"gihroe\" data-start=\"10162\" data-end=\"10190\"\u003e\n\u003cstrong data-start=\"10164\" data-end=\"10184\"\u003eDoor Entry Type:\u003c\/strong\u003e Audio\u003c\/li\u003e\n\u003cli data-section-id=\"1rq6hcy\" data-start=\"10191\" data-end=\"10230\"\u003e\n\u003cstrong data-start=\"10193\" data-end=\"10217\"\u003eAccess Control Type:\u003c\/strong\u003e Coded Keypad\u003c\/li\u003e\n\u003cli data-section-id=\"14h6nv4\" data-start=\"10231\" data-end=\"10266\"\u003e\n\u003cstrong data-start=\"10233\" data-end=\"10263\"\u003eMaximum User Access Codes:\u003c\/strong\u003e 10\u003c\/li\u003e\n\u003cli data-section-id=\"1ykbuot\" data-start=\"10267\" data-end=\"10308\"\u003e\n\u003cstrong data-start=\"10269\" data-end=\"10295\"\u003eLock Release Duration:\u003c\/strong\u003e Programmable\u003c\/li\u003e\n\u003cli data-section-id=\"65fhea\" data-start=\"10309\" data-end=\"10348\"\u003e\n\u003cstrong data-start=\"10311\" data-end=\"10338\"\u003eValid Entry Indication:\u003c\/strong\u003e Green LED\u003c\/li\u003e\n\u003cli data-section-id=\"1x34kil\" data-start=\"10349\" data-end=\"10388\"\u003e\n\u003cstrong data-start=\"10351\" data-end=\"10380\"\u003eInvalid Entry Indication:\u003c\/strong\u003e Red LED\u003c\/li\u003e\n\u003cli data-section-id=\"r0lg22\" data-start=\"10389\" data-end=\"10451\"\u003e\n\u003cstrong data-start=\"10391\" data-end=\"10410\"\u003eEntrance Panel:\u003c\/strong\u003e CP106 Series Aluminium Panel with Keypad\u003c\/li\u003e\n\u003cli data-section-id=\"1866nyr\" data-start=\"10452\" data-end=\"10484\"\u003e\n\u003cstrong data-start=\"10454\" data-end=\"10470\"\u003eSpeech Unit:\u003c\/strong\u003e Bell Model 61\u003c\/li\u003e\n\u003cli data-section-id=\"8h067j\" data-start=\"10485\" data-end=\"10514\"\u003e\n\u003cstrong data-start=\"10487\" data-end=\"10504\"\u003ePower Supply:\u003c\/strong\u003e Bell PS4A\u003c\/li\u003e\n\u003cli data-section-id=\"n9boj7\" data-start=\"10515\" data-end=\"10548\"\u003e\n\u003cstrong data-start=\"10517\" data-end=\"10541\"\u003ePower Supply Output:\u003c\/strong\u003e 12V DC\u003c\/li\u003e\n\u003cli data-section-id=\"1ajrej0\" data-start=\"10549\" data-end=\"10578\"\u003e\n\u003cstrong data-start=\"10551\" data-end=\"10575\"\u003ePower Supply Rating:\u003c\/strong\u003e 4A\u003c\/li\u003e\n\u003cli data-section-id=\"tkf8o9\" data-start=\"10579\" data-end=\"10613\"\u003e\n\u003cstrong data-start=\"10581\" data-end=\"10598\"\u003eLock Release:\u003c\/strong\u003e Bell Model 203\u003c\/li\u003e\n\u003cli data-section-id=\"1rpodh9\" data-start=\"10614\" data-end=\"10646\"\u003e\n\u003cstrong data-start=\"10616\" data-end=\"10638\"\u003eLock Release Type:\u003c\/strong\u003e Surface\u003c\/li\u003e\n\u003cli data-section-id=\"qokdop\" data-start=\"10647\" data-end=\"10683\"\u003e\n\u003cstrong data-start=\"10649\" data-end=\"10665\"\u003eProgramming:\u003c\/strong\u003e User Programmable\u003c\/li\u003e\n\u003cli data-section-id=\"3cgwjr\" data-start=\"10684\" data-end=\"10726\"\u003e\n\u003cstrong data-start=\"10686\" data-end=\"10702\"\u003eSystem Type:\u003c\/strong\u003e Standalone Coded Access\u003c\/li\u003e\n\u003cli data-section-id=\"diuy65\" data-start=\"10727\" data-end=\"10768\"\u003e\n\u003cstrong data-start=\"10729\" data-end=\"10759\"\u003eInstallation Instructions:\u003c\/strong\u003e Included\u003c\/li\u003e\n\u003cli data-section-id=\"nnlyvs\" data-start=\"10769\" data-end=\"10809\"\u003e\n\u003cstrong data-start=\"10771\" data-end=\"10800\"\u003eProgramming Instructions:\u003c\/strong\u003e Included\u003c\/li\u003e\n\u003cli data-section-id=\"ga1d9d\" data-start=\"10810\" data-end=\"10877\"\u003e\n\u003cstrong data-start=\"10812\" data-end=\"10837\"\u003eSecurity Application:\u003c\/strong\u003e Basic Coded Access \u0026amp; Visitor Door Entry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"11cc03h\" dir=\"auto\" data-start=\"10879\" data-end=\"10903\"\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul data-start=\"10905\" data-end=\"11356\"\u003e\n\u003cli data-section-id=\"1riz9en\" data-start=\"10905\" data-end=\"10929\"\u003eThree-Flat Conversions\u003c\/li\u003e\n\u003cli data-section-id=\"wtrif2\" data-start=\"10930\" data-end=\"10965\"\u003eThree-Unit Residential Properties\u003c\/li\u003e\n\u003cli data-section-id=\"ds9l1y\" data-start=\"10966\" data-end=\"10993\"\u003eSmall Apartment Buildings\u003c\/li\u003e\n\u003cli data-section-id=\"25i11g\" data-start=\"10994\" data-end=\"11024\"\u003eShared Residential Entrances\u003c\/li\u003e\n\u003cli data-section-id=\"1hyfcr6\" data-start=\"11025\" data-end=\"11053\"\u003eMulti-Occupancy Properties\u003c\/li\u003e\n\u003cli data-section-id=\"1s9sktg\" data-start=\"11054\" data-end=\"11069\"\u003eSmall Offices\u003c\/li\u003e\n\u003cli data-section-id=\"ui9cch\" data-start=\"11070\" data-end=\"11088\"\u003eCommercial Units\u003c\/li\u003e\n\u003cli data-section-id=\"1sqrrwe\" data-start=\"11089\" data-end=\"11100\"\u003eWorkshops\u003c\/li\u003e\n\u003cli data-section-id=\"198t3kd\" data-start=\"11101\" data-end=\"11128\"\u003eSmall Commercial Premises\u003c\/li\u003e\n\u003cli data-section-id=\"avgg55\" data-start=\"11129\" data-end=\"11146\"\u003eStaff Entrances\u003c\/li\u003e\n\u003cli data-section-id=\"1txazo5\" data-start=\"11147\" data-end=\"11169\"\u003eControlled Entrances\u003c\/li\u003e\n\u003cli data-section-id=\"tomxl2\" data-start=\"11170\" data-end=\"11193\"\u003eVisitor Entry Systems\u003c\/li\u003e\n\u003cli data-section-id=\"4yeiiz\" data-start=\"11194\" data-end=\"11222\"\u003eKeyless Entry Applications\u003c\/li\u003e\n\u003cli data-section-id=\"22r37g\" data-start=\"11223\" data-end=\"11241\"\u003eAudio Door Entry\u003c\/li\u003e\n\u003cli data-section-id=\"1q2qg9x\" data-start=\"11242\" data-end=\"11256\"\u003eCoded Access\u003c\/li\u003e\n\u003cli data-section-id=\"1pcaifc\" data-start=\"11257\" data-end=\"11293\"\u003eSurface-Mounted Door Entry Systems\u003c\/li\u003e\n\u003cli data-section-id=\"hf2r7d\" data-start=\"11294\" data-end=\"11322\"\u003eResidential Access Control\u003c\/li\u003e\n\u003cli data-section-id=\"16p0ch5\" data-start=\"11323\" data-end=\"11356\"\u003eLight Commercial Access Control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"12hs2n7\" dir=\"auto\" data-start=\"11358\" data-end=\"11396\"\u003eWhy Choose the Bell System CS106-3?\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"11398\" data-end=\"11571\"\u003eThe \u003cstrong data-start=\"11402\" data-end=\"11425\"\u003eBell System CS106-3\u003c\/strong\u003e provides a practical solution where a common entrance needs to serve \u003cstrong data-start=\"11495\" data-end=\"11570\"\u003ethree separate internal users while also providing coded keyless access\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"11573\" data-end=\"11807\"\u003eThree \u003cstrong data-start=\"11579\" data-end=\"11602\"\u003eBell 801 telephones\u003c\/strong\u003e allow individual occupants to communicate with visitors at the entrance before granting access, while the integrated keypad provides regular authorised users with a faster method of entering the building.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"11809\" data-end=\"12029\"\u003eSupport for \u003cstrong data-start=\"11821\" data-end=\"11853\"\u003eup to 10 unique access codes\u003c\/strong\u003e provides flexibility for residents, employees and other authorised users, while the programmable lock-release duration allows the system to be configured to suit the entrance.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"12031\" data-end=\"12208\"\u003eClear \u003cstrong data-start=\"12037\" data-end=\"12069\"\u003ered and green LED indicators\u003c\/strong\u003e provide straightforward keypad feedback, and the supplied \u003cstrong data-start=\"12128\" data-end=\"12161\"\u003eBell 203 surface lock release\u003c\/strong\u003e provides electrically controlled door opening.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"12210\" data-end=\"12485\"\u003eWith the \u003cstrong data-start=\"12219\" data-end=\"12356\"\u003ealuminium keypad entrance panel, three 801 telephones, model 61 speech unit, PS4A 12V 4A DC power supply and 203 surface lock release\u003c\/strong\u003e supplied as part of the package, the CS106-3 provides the principal components needed for a professional three-way installation.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"12487\" data-end=\"12737\"\u003eFor \u003cstrong data-start=\"12491\" data-end=\"12609\"\u003ethree-flat conversions, small multi-occupancy buildings and commercial premises with three internal call positions\u003c\/strong\u003e, the Bell System CS106-3 offers a straightforward combination of visitor communication, internal door release and coded access.\u003c\/p\u003e","brand":"Bell System","offers":[{"title":"Default Title","offer_id":54885926699354,"sku":"CS106-3","price":382.78,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/cs106-3-handset-door-entry_iksqq67hqpoo1uax.jpg?v=1790773548","url":"https:\/\/account.alertelectrical.com\/products\/bell-system-cs106-3-3-way-coded-door-entry-kit-surface","provider":"Alert Electrical","version":"1.0","type":"link"}