{"product_id":"bell-system-cs106-5-5-way-coded-door-entry-kit-surface","title":"Bell System CS106-5 5-Way Coded Door Entry Kit Surface","description":"\u003ch1 data-section-id=\"4rnd50\" dir=\"auto\" data-start=\"0\" data-end=\"56\" class=\"PDq2pG_selectionAnchorContainer\"\u003eBell System CS106-5 5-Way Coded Door Entry Kit Surface\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2 data-section-id=\"1seuiig\" dir=\"auto\" data-start=\"58\" data-end=\"140\"\u003eCombined 5-Way Audio Door Entry \u0026amp; Coded Access System with Surface Lock Release\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"142\" data-end=\"440\"\u003eThe \u003cstrong data-start=\"146\" data-end=\"196\"\u003eBell System CS106-5 5-Way Coded Door Entry Kit\u003c\/strong\u003e combines a conventional \u003cstrong data-start=\"221\" data-end=\"289\"\u003eaudio door entry system with standalone keypad-controlled access\u003c\/strong\u003e, providing a practical entrance security solution for properties requiring communication with \u003cstrong data-start=\"384\" data-end=\"439\"\u003efive separate users or internal telephone positions\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"442\" data-end=\"759\"\u003eDesigned as the \u003cstrong data-start=\"458\" data-end=\"507\"\u003e5-way version of the Bell System CS106 series\u003c\/strong\u003e, the system allows visitors to call the required property or user from the external entrance panel. Occupants can communicate with callers using their \u003cstrong data-start=\"659\" data-end=\"700\"\u003eBell System 801 door entry telephones\u003c\/strong\u003e before operating the electric lock release to grant entry.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"761\" data-end=\"1045\"\u003eFor residents, staff and other authorised users, the integral \u003cstrong data-start=\"823\" data-end=\"851\"\u003eC106 coded access keypad\u003c\/strong\u003e provides convenient keyless entry. The keypad can be programmed with \u003cstrong data-start=\"921\" data-end=\"953\"\u003eup to 10 unique access codes\u003c\/strong\u003e, allowing multiple authorised users to gain access without relying solely on physical keys.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1047\" data-end=\"1301\"\u003eWhen a valid code is entered, the electric lock release operates for a preset duration. Clear \u003cstrong data-start=\"1141\" data-end=\"1173\"\u003egreen and red LED indicators\u003c\/strong\u003e provide straightforward feedback, with green indicating that the lock release is operating and red indicating an invalid entry.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1303\" data-end=\"1598\"\u003eSupplied with \u003cstrong data-start=\"1317\" data-end=\"1483\"\u003efive Bell 801 telephones, an aluminium entrance panel with integrated keypad, model 61 speech unit, PS4A 12V 4A DC power supply and model 203 surface lock release\u003c\/strong\u003e, the CS106-5 provides the principal components required for a professional five-way coded door-entry installation.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" dir=\"auto\" data-start=\"1600\" data-end=\"1615\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1617\" data-end=\"2467\"\u003e\n\u003cli data-section-id=\"1mp8dm8\" data-start=\"1617\" data-end=\"1669\"\u003eBell System Combined Door Entry \u0026amp; Coded Access Kit\u003c\/li\u003e\n\u003cli data-section-id=\"pgwjdd\" data-start=\"1670\" data-end=\"1692\"\u003eProduct Code CS106-5\u003c\/li\u003e\n\u003cli data-section-id=\"13j9a9a\" data-start=\"1693\" data-end=\"1724\"\u003e5-Way Audio Door Entry System\u003c\/li\u003e\n\u003cli data-section-id=\"izrhsu\" data-start=\"1725\" data-end=\"1776\"\u003eDesigned for Five Users \/ Internal Call Positions\u003c\/li\u003e\n\u003cli data-section-id=\"vg3kl4\" data-start=\"1777\" data-end=\"1810\"\u003eFive Bell System 801 Telephones\u003c\/li\u003e\n\u003cli data-section-id=\"i0b95x\" data-start=\"1811\" data-end=\"1843\"\u003eStandalone Coded Access System\u003c\/li\u003e\n\u003cli data-section-id=\"gafv9p\" data-start=\"1844\" data-end=\"1873\"\u003eSurface-Mount Configuration\u003c\/li\u003e\n\u003cli data-section-id=\"17yn3sm\" data-start=\"1874\" data-end=\"1902\"\u003eAudio Speech Communication\u003c\/li\u003e\n\u003cli data-section-id=\"1sinxus\" data-start=\"1903\" data-end=\"1940\"\u003eIntegrated C106 Coded Access Keypad\u003c\/li\u003e\n\u003cli data-section-id=\"o4gj67\" data-start=\"1941\" data-end=\"1976\"\u003eUp to 10 Unique User Access Codes\u003c\/li\u003e\n\u003cli data-section-id=\"c73ztz\" data-start=\"1977\" data-end=\"2013\"\u003eProgrammable Lock Release Duration\u003c\/li\u003e\n\u003cli data-section-id=\"6gbc94\" data-start=\"2014\" data-end=\"2045\"\u003eGreen Lock Release Status LED\u003c\/li\u003e\n\u003cli data-section-id=\"115bkhq\" data-start=\"2046\" data-end=\"2069\"\u003eRed Invalid-Entry LED\u003c\/li\u003e\n\u003cli data-section-id=\"rbisgf\" data-start=\"2070\" data-end=\"2101\"\u003eAluminium Entrance Door Panel\u003c\/li\u003e\n\u003cli data-section-id=\"f4zop8\" data-start=\"2102\" data-end=\"2136\"\u003eBell System Model 61 Speech Unit\u003c\/li\u003e\n\u003cli data-section-id=\"1gjfnsi\" data-start=\"2137\" data-end=\"2171\"\u003eBell PS4A 12V 4A DC Power Supply\u003c\/li\u003e\n\u003cli data-section-id=\"18tovmx\" data-start=\"2172\" data-end=\"2203\"\u003eBell 203 Surface Lock Release\u003c\/li\u003e\n\u003cli data-section-id=\"g1ttdh\" data-start=\"2204\" data-end=\"2236\"\u003eInternal Door Release Facility\u003c\/li\u003e\n\u003cli data-section-id=\"fes42d\" data-start=\"2237\" data-end=\"2273\"\u003eKeyless Entry for Authorised Users\u003c\/li\u003e\n\u003cli data-section-id=\"9ijmza\" data-start=\"2274\" data-end=\"2313\"\u003eVisitor Calling \u0026amp; Audio Communication\u003c\/li\u003e\n\u003cli data-section-id=\"g2jmns\" data-start=\"2314\" data-end=\"2364\"\u003eInstallation \u0026amp; Programming Instructions Included\u003c\/li\u003e\n\u003cli data-section-id=\"l2vojb\" data-start=\"2365\" data-end=\"2408\"\u003eIdeal for Small Multi-Occupancy Buildings\u003c\/li\u003e\n\u003cli data-section-id=\"119gme5\" data-start=\"2409\" data-end=\"2467\"\u003eSuitable for Residential \u0026amp; Light Commercial Applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"scc6yd\" dir=\"auto\" data-start=\"2469\" data-end=\"2495\"\u003e5-Way Door Entry System\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"2497\" data-end=\"2673\"\u003eThe \u003cstrong data-start=\"2501\" data-end=\"2558\"\u003eCS106-5 is configured as a five-way door-entry system\u003c\/strong\u003e, making it suitable for a common entrance serving five separate properties, users or internal telephone positions.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2675\" data-end=\"2885\"\u003eVisitors use the entrance panel to call the required occupant. The occupant can then communicate with the caller using their internal \u003cstrong data-start=\"2809\" data-end=\"2831\"\u003eBell 801 telephone\u003c\/strong\u003e before deciding whether to release the entrance door.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2887\" data-end=\"3063\"\u003eThis makes the CS106-5 particularly suitable for \u003cstrong data-start=\"2936\" data-end=\"3062\"\u003efive-flat conversions, small apartment buildings, shared residential entrances and suitable multi-user commercial premises\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-section-id=\"2cux0p\" dir=\"auto\" data-start=\"3065\" data-end=\"3102\"\u003eCombined Door Entry \u0026amp; Coded Access\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"3104\" data-end=\"3204\"\u003eThe CS106-5 brings together \u003cstrong data-start=\"3132\" data-end=\"3180\"\u003evisitor door entry and keypad access control\u003c\/strong\u003e within a single system.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3206\" data-end=\"3299\"\u003eVisitors use the external call panel and audio communication facility to contact an occupant.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3301\" data-end=\"3430\"\u003eRegular authorised users can bypass the visitor-call process by entering a valid access code directly into the integrated keypad.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3432\" data-end=\"3544\"\u003eThis provides a convenient combination of controlled visitor entry and keyless access through the same entrance.\u003c\/p\u003e\n\u003ch2 data-section-id=\"zzmq6t\" dir=\"auto\" data-start=\"3546\" data-end=\"3580\"\u003eFive Bell System 801 Telephones\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"3582\" data-end=\"3733\"\u003eThe five-way configuration provides \u003cstrong data-start=\"3618\" data-end=\"3670\"\u003efive Bell System model 801 door entry telephones\u003c\/strong\u003e, giving each user or property an internal communication point.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3735\" data-end=\"3863\"\u003eWhen a visitor calls, the appropriate occupant can speak with them before deciding whether to operate the electric door release.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3865\" data-end=\"3995\"\u003eFor a building containing five individual flats or units, this provides each principal occupant with their own door-entry handset.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1gxcyr8\" dir=\"auto\" data-start=\"3997\" data-end=\"4036\"\u003eAluminium Entrance Panel with Keypad\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"4038\" data-end=\"4136\"\u003eThe system uses a \u003cstrong data-start=\"4056\" data-end=\"4135\"\u003eCP106-series aluminium entrance panel incorporating the coded keypad module\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4138\" data-end=\"4349\"\u003eIntegrating the keypad and visitor-call functions within the entrance panel provides a neat, professional solution without requiring a separate standalone keypad to be mounted alongside the door-entry equipment.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4351\" data-end=\"4469\"\u003eThe aluminium construction provides a smart appearance suitable for a variety of residential and commercial entrances.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1s8evhv\" dir=\"auto\" data-start=\"4471\" data-end=\"4502\"\u003eUp to 10 Unique Access Codes\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"4504\" data-end=\"4576\"\u003eThe \u003cstrong data-start=\"4508\" data-end=\"4575\"\u003eC106 keypad can be programmed with up to 10 unique access codes\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4578\" data-end=\"4705\"\u003eThis provides flexibility for a five-user building because the system is not limited to one access code per internal telephone.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4707\" data-end=\"4830\"\u003eCodes can be allocated to residents, employees or other authorised users according to the requirements of the installation.\u003c\/p\u003e\n\u003ch2 data-section-id=\"7zh0me\" dir=\"auto\" data-start=\"4832\" data-end=\"4859\"\u003eConvenient Keyless Entry\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"4861\" data-end=\"4978\"\u003eRegular building users can enter through the shared entrance without first contacting one of the internal telephones.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4980\" data-end=\"5080\"\u003eEntering a valid code on the keypad activates the electric lock release for the programmed duration.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5082\" data-end=\"5232\"\u003eThis provides convenient \u003cstrong data-start=\"5107\" data-end=\"5125\"\u003ekeyless access\u003c\/strong\u003e while retaining the conventional visitor-call functionality for people who do not have an authorised code.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1r705t6\" dir=\"auto\" data-start=\"5234\" data-end=\"5271\"\u003eProgrammable Lock Release Duration\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"5273\" data-end=\"5395\"\u003eThe C106 coded access system allows the \u003cstrong data-start=\"5313\" data-end=\"5362\"\u003elock release to operate for a preset duration\u003c\/strong\u003e following successful code entry.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5397\" data-end=\"5531\"\u003eThis gives authorised users sufficient time to open the door while avoiding the need for the entrance to remain continuously unlocked.\u003c\/p\u003e\n\u003ch2 data-section-id=\"17w8bzo\" dir=\"auto\" data-start=\"5533\" data-end=\"5562\"\u003eRed \u0026amp; Green LED Indicators\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"5564\" data-end=\"5619\"\u003eThe keypad incorporates clear visual status indication.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5621\" data-end=\"5755\"\u003eThe \u003cstrong data-start=\"5625\" data-end=\"5683\"\u003egreen LED indicates that the lock release is operating\u003c\/strong\u003e, confirming that the code has been accepted and the door can be opened.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5757\" data-end=\"5867\"\u003eThe \u003cstrong data-start=\"5761\" data-end=\"5799\"\u003ered LED indicates an invalid entry\u003c\/strong\u003e, giving immediate feedback when an incorrect code has been entered.\u003c\/p\u003e\n\u003ch2 data-section-id=\"8lbp8h\" dir=\"auto\" data-start=\"5869\" data-end=\"5904\"\u003eBell System Model 61 Speech Unit\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"5906\" data-end=\"6001\"\u003eThe supplied \u003cstrong data-start=\"5919\" data-end=\"5955\"\u003eBell System model 61 speech unit\u003c\/strong\u003e forms part of the audio communication system.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"6003\" data-end=\"6182\"\u003eIt enables speech between the external entrance panel and the internal Bell 801 telephones, allowing occupants to establish who is calling before deciding whether to grant access.\u003c\/p\u003e\n\u003ch2 data-section-id=\"3d40o\" dir=\"auto\" data-start=\"6184\" data-end=\"6214\"\u003ePS4A 12V 4A DC Power Supply\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"6216\" data-end=\"6282\"\u003eThe system includes a \u003cstrong data-start=\"6238\" data-end=\"6281\"\u003eBell System PS4A 12V 4A DC power supply\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"6284\" data-end=\"6376\"\u003eThis provides the low-voltage power required by the compatible components within the system.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"6378\" data-end=\"6518\"\u003eSupplying the power unit as part of the kit simplifies specification for electricians, access-control specialists and door-entry installers.\u003c\/p\u003e\n\u003ch2 data-section-id=\"9ltzus\" dir=\"auto\" data-start=\"6520\" data-end=\"6552\"\u003eBell 203 Surface Lock Release\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"6554\" data-end=\"6632\"\u003eA \u003cstrong data-start=\"6556\" data-end=\"6602\"\u003eBell System model 203 surface lock release\u003c\/strong\u003e is included with the CS106-5.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"6634\" data-end=\"6786\"\u003eThis electrically operated release enables the entrance door to be unlocked either from an internal telephone or following entry of a valid keypad code.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"6788\" data-end=\"6916\"\u003eThe surface lock release makes this version of the kit suitable for doors where this type of locking arrangement is appropriate.\u003c\/p\u003e\n\u003ch2 data-section-id=\"kqxxrr\" dir=\"auto\" data-start=\"6918\" data-end=\"6945\"\u003eControlled Visitor Entry\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"6947\" data-end=\"7040\"\u003eVisitors arriving at the building can call the appropriate occupant using the entrance panel.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"7042\" data-end=\"7141\"\u003eThe occupant can then communicate with the caller before deciding whether access should be granted.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"7143\" data-end=\"7291\"\u003eThis provides a straightforward level of visitor access control without requiring the resident or member of staff to physically attend the entrance.\u003c\/p\u003e\n\u003ch2 data-section-id=\"la2kdi\" dir=\"auto\" data-start=\"7293\" data-end=\"7329\"\u003eCoded Entry for Residents \u0026amp; Staff\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"7331\" data-end=\"7431\"\u003eResidents and other regular authorised users can enter their programmed code directly on the keypad.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"7433\" data-end=\"7550\"\u003eThis can reduce dependence on physical keys while providing convenient everyday access through the communal entrance.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"7552\" data-end=\"7691\"\u003eWith \u003cstrong data-start=\"7557\" data-end=\"7584\"\u003e10 available user codes\u003c\/strong\u003e, the keypad provides useful flexibility even though the door-entry section serves five internal positions.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1hb9hgt\" dir=\"auto\" data-start=\"7693\" data-end=\"7719\"\u003eStandalone Coded Access\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"7721\" data-end=\"7819\"\u003eThe coded-access element of the CS106 system operates as a \u003cstrong data-start=\"7780\" data-end=\"7818\"\u003estandalone access-control solution\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"7821\" data-end=\"8009\"\u003eIt is intended for installations where straightforward local coded access is appropriate rather than a more advanced networked, centrally managed or credential-based access-control system.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"8011\" data-end=\"8116\"\u003eThe CS106 series is intended for applications where a \u003cstrong data-start=\"8065\" data-end=\"8115\"\u003ebasic level of security is considered adequate\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-section-id=\"3pxp3y\" dir=\"auto\" data-start=\"8118\" data-end=\"8152\"\u003eIdeal for Five-Flat Conversions\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"8154\" data-end=\"8273\"\u003eThe CS106-5 is particularly suitable for a property converted into \u003cstrong data-start=\"8221\" data-end=\"8246\"\u003efive individual flats\u003c\/strong\u003e sharing one main entrance.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"8275\" data-end=\"8376\"\u003eEach flat can have its own Bell 801 telephone, allowing visitors to contact the appropriate resident.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"8378\" data-end=\"8514\"\u003eResidents can then use the coded keypad for regular entry, while visitors continue to use the conventional call-and-release arrangement.\u003c\/p\u003e\n\u003ch2 data-section-id=\"aiqljl\" dir=\"auto\" data-start=\"8516\" data-end=\"8557\"\u003eSuitable for Small Apartment Buildings\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"8559\" data-end=\"8721\"\u003eThe five-way configuration also makes the system suitable for small purpose-built apartment buildings and other residential developments with five internal users.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"8723\" data-end=\"8874\"\u003eIts combination of individual calling, audio speech and shared coded entry provides a practical solution for straightforward communal entrance control.\u003c\/p\u003e\n\u003ch2 data-section-id=\"8qx738\" dir=\"auto\" data-start=\"8876\" data-end=\"8921\"\u003eSuitable for Light Commercial Applications\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"8923\" data-end=\"9060\"\u003eThe CS106-5 can also be used in appropriate commercial premises where one entrance serves five separate offices, units or internal users.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"9062\" data-end=\"9203\"\u003eEmployees can use programmed access codes for everyday entry, while visitors can call the relevant internal position from the external panel.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1s1thzj\" dir=\"auto\" data-start=\"9205\" data-end=\"9237\"\u003eComplete 5-Way Door Entry Kit\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"9239\" data-end=\"9379\"\u003eThe CS106-5 combines the principal components required for a five-way coded door-entry system, simplifying product selection for installers.\u003c\/p\u003e\n\u003ch3 data-section-id=\"7kf8h6\" dir=\"auto\" data-start=\"9381\" data-end=\"9397\"\u003eKit Contents\u003c\/h3\u003e\n\u003cul data-start=\"9399\" data-end=\"9738\"\u003e\n\u003cli data-section-id=\"1wi6dcb\" data-start=\"9399\" data-end=\"9446\"\u003e\u003cstrong data-start=\"9401\" data-end=\"9446\"\u003e5 x Bell System 801 Door Entry Telephones\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"l2vk3\" data-start=\"9447\" data-end=\"9519\"\u003e\u003cstrong data-start=\"9449\" data-end=\"9519\"\u003e1 x CP106 Series Aluminium Door Panel with Integrated Coded Keypad\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1eipwth\" data-start=\"9520\" data-end=\"9562\"\u003e\u003cstrong data-start=\"9522\" data-end=\"9562\"\u003e1 x Bell System Model 61 Speech Unit\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"6zpldq\" data-start=\"9563\" data-end=\"9612\"\u003e\u003cstrong data-start=\"9565\" data-end=\"9612\"\u003e1 x Bell System PS4A 12V 4A DC Power Supply\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"25cuqy\" data-start=\"9613\" data-end=\"9665\"\u003e\u003cstrong data-start=\"9615\" data-end=\"9665\"\u003e1 x Bell System Model 203 Surface Lock Release\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1fipoy4\" data-start=\"9666\" data-end=\"9702\"\u003e\u003cstrong data-start=\"9668\" data-end=\"9702\"\u003eFull Installation Instructions\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"16ukp5\" data-start=\"9703\" data-end=\"9738\"\u003e\u003cstrong data-start=\"9705\" data-end=\"9738\"\u003eFull Programming Instructions\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1cgu054\" dir=\"auto\" data-start=\"9740\" data-end=\"9767\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"9769\" data-end=\"10793\"\u003e\n\u003cli data-section-id=\"jvy697\" data-start=\"9769\" data-end=\"9793\"\u003e\n\u003cstrong data-start=\"9771\" data-end=\"9781\"\u003eBrand:\u003c\/strong\u003e Bell System\u003c\/li\u003e\n\u003cli data-section-id=\"ifq57y\" data-start=\"9794\" data-end=\"9813\"\u003e\n\u003cstrong data-start=\"9796\" data-end=\"9807\"\u003eSeries:\u003c\/strong\u003e CS106\u003c\/li\u003e\n\u003cli data-section-id=\"19h2nhn\" data-start=\"9814\" data-end=\"9841\"\u003e\n\u003cstrong data-start=\"9816\" data-end=\"9833\"\u003eProduct Code:\u003c\/strong\u003e CS106-5\u003c\/li\u003e\n\u003cli data-section-id=\"91g34d\" data-start=\"9842\" data-end=\"9906\"\u003e\n\u003cstrong data-start=\"9844\" data-end=\"9861\"\u003eProduct Type:\u003c\/strong\u003e Combined Audio Door Entry \u0026amp; Coded Access Kit\u003c\/li\u003e\n\u003cli data-section-id=\"17mdhs\" data-start=\"9907\" data-end=\"9940\"\u003e\n\u003cstrong data-start=\"9909\" data-end=\"9934\"\u003eSystem Configuration:\u003c\/strong\u003e 5-Way\u003c\/li\u003e\n\u003cli data-section-id=\"1r04trx\" data-start=\"9941\" data-end=\"9979\"\u003e\n\u003cstrong data-start=\"9943\" data-end=\"9977\"\u003eNumber of Internal Telephones:\u003c\/strong\u003e 5\u003c\/li\u003e\n\u003cli data-section-id=\"1loqnfp\" data-start=\"9980\" data-end=\"10027\"\u003e\n\u003cstrong data-start=\"9982\" data-end=\"10011\"\u003eInternal Telephone Model:\u003c\/strong\u003e Bell System 801\u003c\/li\u003e\n\u003cli data-section-id=\"1r5s1aq\" data-start=\"10028\" data-end=\"10056\"\u003e\n\u003cstrong data-start=\"10030\" data-end=\"10048\"\u003eMounting Type:\u003c\/strong\u003e Surface\u003c\/li\u003e\n\u003cli data-section-id=\"gihroe\" data-start=\"10057\" data-end=\"10085\"\u003e\n\u003cstrong data-start=\"10059\" data-end=\"10079\"\u003eDoor Entry Type:\u003c\/strong\u003e Audio\u003c\/li\u003e\n\u003cli data-section-id=\"1rq6hcy\" data-start=\"10086\" data-end=\"10125\"\u003e\n\u003cstrong data-start=\"10088\" data-end=\"10112\"\u003eAccess Control Type:\u003c\/strong\u003e Coded Keypad\u003c\/li\u003e\n\u003cli data-section-id=\"14h6nv4\" data-start=\"10126\" data-end=\"10161\"\u003e\n\u003cstrong data-start=\"10128\" data-end=\"10158\"\u003eMaximum User Access Codes:\u003c\/strong\u003e 10\u003c\/li\u003e\n\u003cli data-section-id=\"1ykbuot\" data-start=\"10162\" data-end=\"10203\"\u003e\n\u003cstrong data-start=\"10164\" data-end=\"10190\"\u003eLock Release Duration:\u003c\/strong\u003e Programmable\u003c\/li\u003e\n\u003cli data-section-id=\"65fhea\" data-start=\"10204\" data-end=\"10243\"\u003e\n\u003cstrong data-start=\"10206\" data-end=\"10233\"\u003eValid Entry Indication:\u003c\/strong\u003e Green LED\u003c\/li\u003e\n\u003cli data-section-id=\"1x34kil\" data-start=\"10244\" data-end=\"10283\"\u003e\n\u003cstrong data-start=\"10246\" data-end=\"10275\"\u003eInvalid Entry Indication:\u003c\/strong\u003e Red LED\u003c\/li\u003e\n\u003cli data-section-id=\"r0lg22\" data-start=\"10284\" data-end=\"10346\"\u003e\n\u003cstrong data-start=\"10286\" data-end=\"10305\"\u003eEntrance Panel:\u003c\/strong\u003e CP106 Series Aluminium Panel with Keypad\u003c\/li\u003e\n\u003cli data-section-id=\"12bd56e\" data-start=\"10347\" data-end=\"10386\"\u003e\n\u003cstrong data-start=\"10349\" data-end=\"10365\"\u003eSpeech Unit:\u003c\/strong\u003e Bell System Model 61\u003c\/li\u003e\n\u003cli data-section-id=\"1j2kdje\" data-start=\"10387\" data-end=\"10423\"\u003e\n\u003cstrong data-start=\"10389\" data-end=\"10406\"\u003ePower Supply:\u003c\/strong\u003e Bell System PS4A\u003c\/li\u003e\n\u003cli data-section-id=\"n9boj7\" data-start=\"10424\" data-end=\"10457\"\u003e\n\u003cstrong data-start=\"10426\" data-end=\"10450\"\u003ePower Supply Output:\u003c\/strong\u003e 12V DC\u003c\/li\u003e\n\u003cli data-section-id=\"1ajrej0\" data-start=\"10458\" data-end=\"10487\"\u003e\n\u003cstrong data-start=\"10460\" data-end=\"10484\"\u003ePower Supply Rating:\u003c\/strong\u003e 4A\u003c\/li\u003e\n\u003cli data-section-id=\"1e70418\" data-start=\"10488\" data-end=\"10529\"\u003e\n\u003cstrong data-start=\"10490\" data-end=\"10507\"\u003eLock Release:\u003c\/strong\u003e Bell System Model 203\u003c\/li\u003e\n\u003cli data-section-id=\"1rpodh9\" data-start=\"10530\" data-end=\"10562\"\u003e\n\u003cstrong data-start=\"10532\" data-end=\"10554\"\u003eLock Release Type:\u003c\/strong\u003e Surface\u003c\/li\u003e\n\u003cli data-section-id=\"qokdop\" data-start=\"10563\" data-end=\"10599\"\u003e\n\u003cstrong data-start=\"10565\" data-end=\"10581\"\u003eProgramming:\u003c\/strong\u003e User Programmable\u003c\/li\u003e\n\u003cli data-section-id=\"3cgwjr\" data-start=\"10600\" data-end=\"10642\"\u003e\n\u003cstrong data-start=\"10602\" data-end=\"10618\"\u003eSystem Type:\u003c\/strong\u003e Standalone Coded Access\u003c\/li\u003e\n\u003cli data-section-id=\"diuy65\" data-start=\"10643\" data-end=\"10684\"\u003e\n\u003cstrong data-start=\"10645\" data-end=\"10675\"\u003eInstallation Instructions:\u003c\/strong\u003e Included\u003c\/li\u003e\n\u003cli data-section-id=\"nnlyvs\" data-start=\"10685\" data-end=\"10725\"\u003e\n\u003cstrong data-start=\"10687\" data-end=\"10716\"\u003eProgramming Instructions:\u003c\/strong\u003e Included\u003c\/li\u003e\n\u003cli data-section-id=\"ga1d9d\" data-start=\"10726\" data-end=\"10793\"\u003e\n\u003cstrong data-start=\"10728\" data-end=\"10753\"\u003eSecurity Application:\u003c\/strong\u003e Basic Coded Access \u0026amp; Visitor Door Entry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"11cc03h\" dir=\"auto\" data-start=\"10795\" data-end=\"10819\"\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul data-start=\"10821\" data-end=\"11316\"\u003e\n\u003cli data-section-id=\"kddqa5\" data-start=\"10821\" data-end=\"10844\"\u003eFive-Flat Conversions\u003c\/li\u003e\n\u003cli data-section-id=\"bqwcz0\" data-start=\"10845\" data-end=\"10879\"\u003eFive-Unit Residential Properties\u003c\/li\u003e\n\u003cli data-section-id=\"ds9l1y\" data-start=\"10880\" data-end=\"10907\"\u003eSmall Apartment Buildings\u003c\/li\u003e\n\u003cli data-section-id=\"25i11g\" data-start=\"10908\" data-end=\"10938\"\u003eShared Residential Entrances\u003c\/li\u003e\n\u003cli data-section-id=\"1hyfcr6\" data-start=\"10939\" data-end=\"10967\"\u003eMulti-Occupancy Properties\u003c\/li\u003e\n\u003cli data-section-id=\"13lctdx\" data-start=\"10968\" data-end=\"10988\"\u003eCommunal Entrances\u003c\/li\u003e\n\u003cli data-section-id=\"1s9sktg\" data-start=\"10989\" data-end=\"11004\"\u003eSmall Offices\u003c\/li\u003e\n\u003cli data-section-id=\"w2yodl\" data-start=\"11005\" data-end=\"11029\"\u003eMulti-Office Buildings\u003c\/li\u003e\n\u003cli data-section-id=\"ui9cch\" data-start=\"11030\" data-end=\"11048\"\u003eCommercial Units\u003c\/li\u003e\n\u003cli data-section-id=\"1sqrrwe\" data-start=\"11049\" data-end=\"11060\"\u003eWorkshops\u003c\/li\u003e\n\u003cli data-section-id=\"198t3kd\" data-start=\"11061\" data-end=\"11088\"\u003eSmall Commercial Premises\u003c\/li\u003e\n\u003cli data-section-id=\"avgg55\" data-start=\"11089\" data-end=\"11106\"\u003eStaff Entrances\u003c\/li\u003e\n\u003cli data-section-id=\"1txazo5\" data-start=\"11107\" data-end=\"11129\"\u003eControlled Entrances\u003c\/li\u003e\n\u003cli data-section-id=\"tomxl2\" data-start=\"11130\" data-end=\"11153\"\u003eVisitor Entry Systems\u003c\/li\u003e\n\u003cli data-section-id=\"4yeiiz\" data-start=\"11154\" data-end=\"11182\"\u003eKeyless Entry Applications\u003c\/li\u003e\n\u003cli data-section-id=\"22r37g\" data-start=\"11183\" data-end=\"11201\"\u003eAudio Door Entry\u003c\/li\u003e\n\u003cli data-section-id=\"1q2qg9x\" data-start=\"11202\" data-end=\"11216\"\u003eCoded Access\u003c\/li\u003e\n\u003cli data-section-id=\"1pcaifc\" data-start=\"11217\" data-end=\"11253\"\u003eSurface-Mounted Door Entry Systems\u003c\/li\u003e\n\u003cli data-section-id=\"hf2r7d\" data-start=\"11254\" data-end=\"11282\"\u003eResidential Access Control\u003c\/li\u003e\n\u003cli data-section-id=\"16p0ch5\" data-start=\"11283\" data-end=\"11316\"\u003eLight Commercial Access Control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"12hs2lh\" dir=\"auto\" data-start=\"11318\" data-end=\"11356\"\u003eWhy Choose the Bell System CS106-5?\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"11358\" data-end=\"11516\"\u003eThe \u003cstrong data-start=\"11362\" data-end=\"11385\"\u003eBell System CS106-5\u003c\/strong\u003e provides a straightforward way to combine \u003cstrong data-start=\"11428\" data-end=\"11494\"\u003efive-way audio visitor communication with coded keyless access\u003c\/strong\u003e at a shared entrance.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"11518\" data-end=\"11778\"\u003eFive \u003cstrong data-start=\"11523\" data-end=\"11553\"\u003eBell System 801 telephones\u003c\/strong\u003e provide individual internal communication points, allowing occupants to speak with visitors before operating the electric door release. Meanwhile, regular authorised users can gain entry directly using the integrated keypad.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"11780\" data-end=\"12026\"\u003eSupport for \u003cstrong data-start=\"11792\" data-end=\"11824\"\u003eup to 10 unique access codes\u003c\/strong\u003e gives the system useful flexibility for residents, employees and other approved users, while the programmable lock-release duration allows the access function to be configured to suit the installation.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"12028\" data-end=\"12206\"\u003eClear \u003cstrong data-start=\"12034\" data-end=\"12066\"\u003ered and green LED indicators\u003c\/strong\u003e make keypad operation easy to understand, and the supplied \u003cstrong data-start=\"12126\" data-end=\"12159\"\u003eBell 203 surface lock release\u003c\/strong\u003e provides electrically controlled door opening.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"12208\" data-end=\"12470\"\u003eWith the \u003cstrong data-start=\"12217\" data-end=\"12353\"\u003efive 801 telephones, aluminium keypad entrance panel, model 61 speech unit, PS4A 12V 4A DC power supply and 203 surface lock release\u003c\/strong\u003e supplied as part of the package, the CS106-5 provides a convenient solution for professional five-way installations.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"12472\" data-end=\"12715\"\u003eFor \u003cstrong data-start=\"12476\" data-end=\"12593\"\u003efive-flat conversions, small apartment buildings, shared residential entrances and suitable commercial properties\u003c\/strong\u003e, the Bell System CS106-5 offers a practical combination of visitor communication, internal door release and coded access.\u003c\/p\u003e","brand":"Bell System","offers":[{"title":"Default Title","offer_id":54886128058714,"sku":"CS106-5","price":494.03,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/cs106-5-handset-door-entry_glagrnjqkissgpon.jpg?v=1790773951","url":"https:\/\/account.alertelectrical.com\/products\/bell-system-cs106-5-5-way-coded-door-entry-kit-surface","provider":"Alert Electrical","version":"1.0","type":"link"}