{"product_id":"bell-system-cs106-6-6-way-coded-door-entry-kit-surface","title":"Bell System CS106-6 6-Way Coded Door Entry Kit Surface","description":"\u003ch1 data-section-id=\"fj8hc4\" dir=\"auto\" data-start=\"0\" data-end=\"56\" class=\"PDq2pG_selectionAnchorContainer\"\u003eBell System CS106-6 6-Way Coded Door Entry Kit Surface\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2 data-section-id=\"18cptnf\" dir=\"auto\" data-start=\"58\" data-end=\"140\"\u003eCombined 6-Way Audio Door Entry \u0026amp; Coded Access System with Surface Lock Release\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"142\" data-end=\"416\"\u003eThe \u003cstrong data-start=\"146\" data-end=\"196\"\u003eBell System CS106-6 6-Way Coded Door Entry Kit\u003c\/strong\u003e combines traditional \u003cstrong data-start=\"218\" data-end=\"267\"\u003eaudio door entry with standalone coded access\u003c\/strong\u003e, providing a practical entrance-control solution for properties requiring communication with \u003cstrong data-start=\"361\" data-end=\"415\"\u003esix separate users or internal telephone positions\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"418\" data-end=\"740\"\u003eDesigned as the \u003cstrong data-start=\"434\" data-end=\"483\"\u003e6-way version of the Bell System CS106 series\u003c\/strong\u003e, the system enables visitors to call the required property or user from the external entrance panel. Occupants can communicate with visitors through their \u003cstrong data-start=\"639\" data-end=\"680\"\u003eBell System 801 door entry telephones\u003c\/strong\u003e before operating the electric lock release to grant access.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"742\" data-end=\"1036\"\u003eFor residents, staff and other authorised users, the integrated \u003cstrong data-start=\"806\" data-end=\"834\"\u003eC106 coded access keypad\u003c\/strong\u003e provides convenient keyless entry. The keypad can be programmed with \u003cstrong data-start=\"904\" data-end=\"936\"\u003eup to 10 unique access codes\u003c\/strong\u003e, allowing multiple authorised users to access the building without relying solely on physical keys.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1038\" data-end=\"1268\"\u003eWhen a valid code is entered, the lock release operates for a preset duration. The keypad incorporates \u003cstrong data-start=\"1141\" data-end=\"1173\"\u003egreen and red LED indicators\u003c\/strong\u003e, with green indicating that the lock release is operating and red indicating an invalid entry.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1270\" data-end=\"1571\"\u003eSupplied with \u003cstrong data-start=\"1284\" data-end=\"1457\"\u003esix Bell System 801 telephones, a CP106-series aluminium entrance panel with keypad, model 61 speech unit, PS4A 12V 4A DC power supply and model 203 surface lock release\u003c\/strong\u003e, the CS106-6 provides the principal components required for a professional six-way coded door-entry installation.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" dir=\"auto\" data-start=\"1573\" data-end=\"1588\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1590\" data-end=\"2432\"\u003e\n\u003cli data-section-id=\"1mp8dm8\" data-start=\"1590\" data-end=\"1642\"\u003eBell System Combined Door Entry \u0026amp; Coded Access Kit\u003c\/li\u003e\n\u003cli data-section-id=\"pgwjde\" data-start=\"1643\" data-end=\"1665\"\u003eProduct Code CS106-6\u003c\/li\u003e\n\u003cli data-section-id=\"11pssrx\" data-start=\"1666\" data-end=\"1697\"\u003e6-Way Audio Door Entry System\u003c\/li\u003e\n\u003cli data-section-id=\"34f0ow\" data-start=\"1698\" data-end=\"1748\"\u003eDesigned for Six Users \/ Internal Call Positions\u003c\/li\u003e\n\u003cli data-section-id=\"17sxbc6\" data-start=\"1749\" data-end=\"1781\"\u003eSix Bell System 801 Telephones\u003c\/li\u003e\n\u003cli data-section-id=\"i0b95x\" data-start=\"1782\" data-end=\"1814\"\u003eStandalone Coded Access System\u003c\/li\u003e\n\u003cli data-section-id=\"gafv9p\" data-start=\"1815\" data-end=\"1844\"\u003eSurface-Mount Configuration\u003c\/li\u003e\n\u003cli data-section-id=\"17yn3sm\" data-start=\"1845\" data-end=\"1873\"\u003eAudio Speech Communication\u003c\/li\u003e\n\u003cli data-section-id=\"1sinxus\" data-start=\"1874\" data-end=\"1911\"\u003eIntegrated C106 Coded Access Keypad\u003c\/li\u003e\n\u003cli data-section-id=\"o4gj67\" data-start=\"1912\" data-end=\"1947\"\u003eUp to 10 Unique User Access Codes\u003c\/li\u003e\n\u003cli data-section-id=\"c73ztz\" data-start=\"1948\" data-end=\"1984\"\u003eProgrammable Lock Release Duration\u003c\/li\u003e\n\u003cli data-section-id=\"6gbc94\" data-start=\"1985\" data-end=\"2016\"\u003eGreen Lock Release Status LED\u003c\/li\u003e\n\u003cli data-section-id=\"115bkhq\" data-start=\"2017\" data-end=\"2040\"\u003eRed Invalid-Entry LED\u003c\/li\u003e\n\u003cli data-section-id=\"rbisgf\" data-start=\"2041\" data-end=\"2072\"\u003eAluminium Entrance Door Panel\u003c\/li\u003e\n\u003cli data-section-id=\"f4zop8\" data-start=\"2073\" data-end=\"2107\"\u003eBell System Model 61 Speech Unit\u003c\/li\u003e\n\u003cli data-section-id=\"1gjfnsi\" data-start=\"2108\" data-end=\"2142\"\u003eBell PS4A 12V 4A DC Power Supply\u003c\/li\u003e\n\u003cli data-section-id=\"18tovmx\" data-start=\"2143\" data-end=\"2174\"\u003eBell 203 Surface Lock Release\u003c\/li\u003e\n\u003cli data-section-id=\"g1ttdh\" data-start=\"2175\" data-end=\"2207\"\u003eInternal Door Release Facility\u003c\/li\u003e\n\u003cli data-section-id=\"fes42d\" data-start=\"2208\" data-end=\"2244\"\u003eKeyless Entry for Authorised Users\u003c\/li\u003e\n\u003cli data-section-id=\"9ijmza\" data-start=\"2245\" data-end=\"2284\"\u003eVisitor Calling \u0026amp; Audio Communication\u003c\/li\u003e\n\u003cli data-section-id=\"g2jmns\" data-start=\"2285\" data-end=\"2335\"\u003eInstallation \u0026amp; Programming Instructions Included\u003c\/li\u003e\n\u003cli data-section-id=\"1imqxk8\" data-start=\"2336\" data-end=\"2373\"\u003eIdeal for Multi-Occupancy Buildings\u003c\/li\u003e\n\u003cli data-section-id=\"119gme5\" data-start=\"2374\" data-end=\"2432\"\u003eSuitable for Residential \u0026amp; Light Commercial Applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"13ooegm\" dir=\"auto\" data-start=\"2434\" data-end=\"2460\"\u003e6-Way Door Entry System\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"2462\" data-end=\"2629\"\u003eThe \u003cstrong data-start=\"2466\" data-end=\"2511\"\u003eCS106-6 is configured as a six-way system\u003c\/strong\u003e, making it suitable for a common entrance serving six separate properties, occupants or internal telephone positions.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2631\" data-end=\"2827\"\u003eVisitors use the entrance panel to call the appropriate occupant. The occupant can then speak with the visitor using their internal Bell 801 handset before deciding whether to unlock the entrance.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2829\" data-end=\"3004\"\u003eThis makes the CS106-6 particularly suitable for \u003cstrong data-start=\"2878\" data-end=\"3003\"\u003esix-flat conversions, small apartment buildings, shared residential entrances and suitable multi-user commercial premises\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-section-id=\"2cux0p\" dir=\"auto\" data-start=\"3006\" data-end=\"3043\"\u003eCombined Door Entry \u0026amp; Coded Access\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"3045\" data-end=\"3141\"\u003eThe CS106-6 brings together \u003cstrong data-start=\"3073\" data-end=\"3126\"\u003evisitor communication and keypad-controlled entry\u003c\/strong\u003e in one system.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3143\" data-end=\"3264\"\u003eVisitors use the door-entry panel to call an occupant and establish two-way audio communication before access is granted.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3266\" data-end=\"3393\"\u003eRegular authorised users can bypass the visitor-call process by entering their programmed access code directly into the keypad.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3395\" data-end=\"3534\"\u003eThis combination provides a convenient solution for entrances where both visitor-controlled access and everyday keyless entry are required.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1189kh7\" dir=\"auto\" data-start=\"3536\" data-end=\"3569\"\u003eSix Bell System 801 Telephones\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"3571\" data-end=\"3695\"\u003eThe six-way configuration provides \u003cstrong data-start=\"3606\" data-end=\"3646\"\u003esix Bell System model 801 telephones\u003c\/strong\u003e for installation at the internal user positions.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3697\" data-end=\"3803\"\u003eEach telephone provides an audio communication point between the occupant and the external entrance panel.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3805\" data-end=\"3944\"\u003eWhen a visitor calls, the appropriate occupant can communicate with them before using the telephone's door-release facility to grant entry.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3946\" data-end=\"4069\"\u003eThis makes the kit particularly convenient for a building containing six individual flats or other separate internal users.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1kim4hp\" dir=\"auto\" data-start=\"4071\" data-end=\"4116\"\u003eAluminium Entrance Panel with Coded Keypad\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"4118\" data-end=\"4217\"\u003eThe CS106-6 uses a \u003cstrong data-start=\"4137\" data-end=\"4216\"\u003eCP106-series aluminium entrance panel incorporating the coded keypad module\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4219\" data-end=\"4409\"\u003eIntegrating the keypad with the visitor calling facilities provides a neat and professional entrance arrangement while avoiding the need to install a completely separate coded-access keypad.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4411\" data-end=\"4534\"\u003eThe aluminium construction also provides a smart appearance suitable for residential and commercial entrance installations.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1s8evhv\" dir=\"auto\" data-start=\"4536\" data-end=\"4567\"\u003eUp to 10 Unique Access Codes\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"4569\" data-end=\"4632\"\u003eThe \u003cstrong data-start=\"4573\" data-end=\"4631\"\u003eC106 keypad supports up to 10 unique user access codes\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4634\" data-end=\"4735\"\u003eAlthough the door-entry system serves six internal positions, the keypad is not limited to six codes.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4737\" data-end=\"4916\"\u003eAdditional codes can therefore be allocated to other authorised users where required, providing useful flexibility for residents, staff, building managers or other approved users.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1bs933q\" dir=\"auto\" data-start=\"4918\" data-end=\"4946\"\u003eConvenient Keyless Access\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"4948\" data-end=\"5040\"\u003eResidents and other regular building users can gain entry by entering their programmed code.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5042\" data-end=\"5143\"\u003eWhen the keypad recognises a valid code, it operates the electric lock release for the preset period.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5145\" data-end=\"5306\"\u003eThis provides convenient \u003cstrong data-start=\"5170\" data-end=\"5188\"\u003ekeyless access\u003c\/strong\u003e while retaining the conventional audio door-entry system for visitors and callers who do not have an authorised code.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1r705t6\" dir=\"auto\" data-start=\"5308\" data-end=\"5345\"\u003eProgrammable Lock Release Duration\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"5347\" data-end=\"5413\"\u003eThe C106 keypad provides a \u003cstrong data-start=\"5374\" data-end=\"5412\"\u003eprogrammable lock-release duration\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5415\" data-end=\"5573\"\u003eFollowing successful entry of an authorised code, the release operates for the preset period, allowing sufficient time for the user to open the entrance door.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5575\" data-end=\"5660\"\u003eThis provides controlled operation without leaving the entrance permanently unlocked.\u003c\/p\u003e\n\u003ch2 data-section-id=\"ui90u8\" dir=\"auto\" data-start=\"5662\" data-end=\"5698\"\u003eRed \u0026amp; Green LED Status Indicators\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"5700\" data-end=\"5792\"\u003eThe keypad incorporates simple visual indication to make everyday operation straightforward.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5794\" data-end=\"5901\"\u003eThe \u003cstrong data-start=\"5798\" data-end=\"5856\"\u003egreen LED indicates that the lock release is operating\u003c\/strong\u003e, confirming that the code has been accepted.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5903\" data-end=\"6016\"\u003eThe \u003cstrong data-start=\"5907\" data-end=\"5945\"\u003ered LED indicates an invalid entry\u003c\/strong\u003e, providing immediate feedback when an incorrect code has been entered.\u003c\/p\u003e\n\u003ch2 data-section-id=\"8lbp8h\" dir=\"auto\" data-start=\"6018\" data-end=\"6053\"\u003eBell System Model 61 Speech Unit\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"6055\" data-end=\"6158\"\u003eThe system includes a \u003cstrong data-start=\"6077\" data-end=\"6113\"\u003eBell System model 61 speech unit\u003c\/strong\u003e as part of the audio door-entry arrangement.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"6160\" data-end=\"6337\"\u003eThe speech unit enables communication between the external entrance panel and the internal 801 telephones, allowing occupants to establish who is calling before granting access.\u003c\/p\u003e\n\u003ch2 data-section-id=\"3d40o\" dir=\"auto\" data-start=\"6339\" data-end=\"6369\"\u003ePS4A 12V 4A DC Power Supply\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"6371\" data-end=\"6434\"\u003eThe kit includes a \u003cstrong data-start=\"6390\" data-end=\"6433\"\u003eBell System PS4A 12V 4A DC power supply\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"6436\" data-end=\"6528\"\u003eThis provides the low-voltage power required by the compatible components within the system.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"6530\" data-end=\"6682\"\u003eSupplying the appropriate power supply as part of the package simplifies specification for electricians, security contractors and door-entry installers.\u003c\/p\u003e\n\u003ch2 data-section-id=\"9ltzus\" dir=\"auto\" data-start=\"6684\" data-end=\"6716\"\u003eBell 203 Surface Lock Release\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"6718\" data-end=\"6796\"\u003eA \u003cstrong data-start=\"6720\" data-end=\"6766\"\u003eBell System model 203 surface lock release\u003c\/strong\u003e is supplied with the CS106-6.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"6798\" data-end=\"6967\"\u003eThis electrically operated release enables the entrance door to be unlocked either from an internal telephone or following successful entry of an authorised keypad code.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"6969\" data-end=\"7098\"\u003eThe included surface release makes the kit particularly suitable for doors where this type of locking arrangement is appropriate.\u003c\/p\u003e\n\u003ch2 data-section-id=\"kqxxrr\" dir=\"auto\" data-start=\"7100\" data-end=\"7127\"\u003eControlled Visitor Entry\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"7129\" data-end=\"7216\"\u003eVisitors arriving at the building use the entrance panel to call the required occupant.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"7218\" data-end=\"7323\"\u003eThe occupant can then speak with the caller from inside before deciding whether access should be granted.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"7325\" data-end=\"7463\"\u003eThis provides a straightforward method of controlling visitor entry without requiring the occupant to physically attend the main entrance.\u003c\/p\u003e\n\u003ch2 data-section-id=\"la2kdi\" dir=\"auto\" data-start=\"7465\" data-end=\"7501\"\u003eCoded Entry for Residents \u0026amp; Staff\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"7503\" data-end=\"7602\"\u003eResidents, employees and other authorised users can enter the building directly through the keypad.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"7604\" data-end=\"7725\"\u003eThis can reduce dependence on physical keys and provides a convenient method of everyday entry through a shared entrance.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"7727\" data-end=\"7843\"\u003eWith \u003cstrong data-start=\"7732\" data-end=\"7770\"\u003eup to 10 programmable access codes\u003c\/strong\u003e, the system provides useful flexibility for a range of authorised users.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1hb9hgt\" dir=\"auto\" data-start=\"7845\" data-end=\"7871\"\u003eStandalone Coded Access\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"7873\" data-end=\"7954\"\u003eThe coded-access element of the CS106 series operates as a \u003cstrong data-start=\"7932\" data-end=\"7953\"\u003estandalone system\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"7956\" data-end=\"8086\"\u003eIt provides straightforward local keypad access without requiring a larger networked or centrally managed access-control platform.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"8088\" data-end=\"8297\"\u003eThe CS106 series is intended for installations where a \u003cstrong data-start=\"8143\" data-end=\"8193\"\u003ebasic level of security is considered adequate\u003c\/strong\u003e, making it suitable for straightforward residential and light-commercial entrance-control applications.\u003c\/p\u003e\n\u003ch2 data-section-id=\"qvx78g\" dir=\"auto\" data-start=\"8299\" data-end=\"8332\"\u003eIdeal for Six-Flat Conversions\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"8334\" data-end=\"8458\"\u003eThe CS106-6 is particularly suitable for a converted property containing \u003cstrong data-start=\"8407\" data-end=\"8457\"\u003esix individual flats sharing one main entrance\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"8460\" data-end=\"8579\"\u003eEach flat can be provided with its own Bell 801 telephone, enabling visitors to call the appropriate resident directly.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"8581\" data-end=\"8731\"\u003eResidents can use the integrated keypad for regular access, while visitors continue to use the conventional call, speech and door-release arrangement.\u003c\/p\u003e\n\u003ch2 data-section-id=\"aiqljl\" dir=\"auto\" data-start=\"8733\" data-end=\"8774\"\u003eSuitable for Small Apartment Buildings\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"8776\" data-end=\"8935\"\u003eThe six-way configuration is also suitable for purpose-built apartment buildings and other small multi-occupancy developments with six internal user positions.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"8937\" data-end=\"9116\"\u003eIts combination of individual visitor calling, audio communication and shared coded access provides the core functionality required for a straightforward communal entrance system.\u003c\/p\u003e\n\u003ch2 data-section-id=\"8qx738\" dir=\"auto\" data-start=\"9118\" data-end=\"9163\"\u003eSuitable for Light Commercial Applications\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"9165\" data-end=\"9301\"\u003eThe CS106-6 can also be used in suitable commercial properties where one entrance serves several separate users, offices or departments.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"9303\" data-end=\"9447\"\u003eStaff can use keypad codes for everyday access, while visitors can contact the relevant internal position through the external door-entry panel.\u003c\/p\u003e\n\u003ch2 data-section-id=\"8leyp8\" dir=\"auto\" data-start=\"9449\" data-end=\"9481\"\u003eComplete 6-Way Door Entry Kit\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"9483\" data-end=\"9629\"\u003eThe CS106-6 combines the principal components required for a six-way coded door-entry installation, helping simplify specification and purchasing.\u003c\/p\u003e\n\u003ch3 data-section-id=\"7kf8h6\" dir=\"auto\" data-start=\"9631\" data-end=\"9647\"\u003eKit Contents\u003c\/h3\u003e\n\u003cul data-start=\"9649\" data-end=\"9977\"\u003e\n\u003cli data-section-id=\"160m5xk\" data-start=\"9649\" data-end=\"9696\"\u003e\u003cstrong data-start=\"9651\" data-end=\"9696\"\u003e6 x Bell System 801 Door Entry Telephones\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1gftac4\" data-start=\"9697\" data-end=\"9758\"\u003e\u003cstrong data-start=\"9699\" data-end=\"9758\"\u003e1 x CP106 Series Aluminium Door Panel with Coded Keypad\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1eipwth\" data-start=\"9759\" data-end=\"9801\"\u003e\u003cstrong data-start=\"9761\" data-end=\"9801\"\u003e1 x Bell System Model 61 Speech Unit\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"6zpldq\" data-start=\"9802\" data-end=\"9851\"\u003e\u003cstrong data-start=\"9804\" data-end=\"9851\"\u003e1 x Bell System PS4A 12V 4A DC Power Supply\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"25cuqy\" data-start=\"9852\" data-end=\"9904\"\u003e\u003cstrong data-start=\"9854\" data-end=\"9904\"\u003e1 x Bell System Model 203 Surface Lock Release\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1fipoy4\" data-start=\"9905\" data-end=\"9941\"\u003e\u003cstrong data-start=\"9907\" data-end=\"9941\"\u003eFull Installation Instructions\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"16ukp5\" data-start=\"9942\" data-end=\"9977\"\u003e\u003cstrong data-start=\"9944\" data-end=\"9977\"\u003eFull Programming Instructions\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1cgu054\" dir=\"auto\" data-start=\"9979\" data-end=\"10006\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"10008\" data-end=\"11032\"\u003e\n\u003cli data-section-id=\"jvy697\" data-start=\"10008\" data-end=\"10032\"\u003e\n\u003cstrong data-start=\"10010\" data-end=\"10020\"\u003eBrand:\u003c\/strong\u003e Bell System\u003c\/li\u003e\n\u003cli data-section-id=\"ifq57y\" data-start=\"10033\" data-end=\"10052\"\u003e\n\u003cstrong data-start=\"10035\" data-end=\"10046\"\u003eSeries:\u003c\/strong\u003e CS106\u003c\/li\u003e\n\u003cli data-section-id=\"19h2nhk\" data-start=\"10053\" data-end=\"10080\"\u003e\n\u003cstrong data-start=\"10055\" data-end=\"10072\"\u003eProduct Code:\u003c\/strong\u003e CS106-6\u003c\/li\u003e\n\u003cli data-section-id=\"91g34d\" data-start=\"10081\" data-end=\"10145\"\u003e\n\u003cstrong data-start=\"10083\" data-end=\"10100\"\u003eProduct Type:\u003c\/strong\u003e Combined Audio Door Entry \u0026amp; Coded Access Kit\u003c\/li\u003e\n\u003cli data-section-id=\"185zyr\" data-start=\"10146\" data-end=\"10179\"\u003e\n\u003cstrong data-start=\"10148\" data-end=\"10173\"\u003eSystem Configuration:\u003c\/strong\u003e 6-Way\u003c\/li\u003e\n\u003cli data-section-id=\"1r04try\" data-start=\"10180\" data-end=\"10218\"\u003e\n\u003cstrong data-start=\"10182\" data-end=\"10216\"\u003eNumber of Internal Telephones:\u003c\/strong\u003e 6\u003c\/li\u003e\n\u003cli data-section-id=\"1loqnfp\" data-start=\"10219\" data-end=\"10266\"\u003e\n\u003cstrong data-start=\"10221\" data-end=\"10250\"\u003eInternal Telephone Model:\u003c\/strong\u003e Bell System 801\u003c\/li\u003e\n\u003cli data-section-id=\"1r5s1aq\" data-start=\"10267\" data-end=\"10295\"\u003e\n\u003cstrong data-start=\"10269\" data-end=\"10287\"\u003eMounting Type:\u003c\/strong\u003e Surface\u003c\/li\u003e\n\u003cli data-section-id=\"gihroe\" data-start=\"10296\" data-end=\"10324\"\u003e\n\u003cstrong data-start=\"10298\" data-end=\"10318\"\u003eDoor Entry Type:\u003c\/strong\u003e Audio\u003c\/li\u003e\n\u003cli data-section-id=\"1rq6hcy\" data-start=\"10325\" data-end=\"10364\"\u003e\n\u003cstrong data-start=\"10327\" data-end=\"10351\"\u003eAccess Control Type:\u003c\/strong\u003e Coded Keypad\u003c\/li\u003e\n\u003cli data-section-id=\"14h6nv4\" data-start=\"10365\" data-end=\"10400\"\u003e\n\u003cstrong data-start=\"10367\" data-end=\"10397\"\u003eMaximum User Access Codes:\u003c\/strong\u003e 10\u003c\/li\u003e\n\u003cli data-section-id=\"1ykbuot\" data-start=\"10401\" data-end=\"10442\"\u003e\n\u003cstrong data-start=\"10403\" data-end=\"10429\"\u003eLock Release Duration:\u003c\/strong\u003e Programmable\u003c\/li\u003e\n\u003cli data-section-id=\"65fhea\" data-start=\"10443\" data-end=\"10482\"\u003e\n\u003cstrong data-start=\"10445\" data-end=\"10472\"\u003eValid Entry Indication:\u003c\/strong\u003e Green LED\u003c\/li\u003e\n\u003cli data-section-id=\"1x34kil\" data-start=\"10483\" data-end=\"10522\"\u003e\n\u003cstrong data-start=\"10485\" data-end=\"10514\"\u003eInvalid Entry Indication:\u003c\/strong\u003e Red LED\u003c\/li\u003e\n\u003cli data-section-id=\"r0lg22\" data-start=\"10523\" data-end=\"10585\"\u003e\n\u003cstrong data-start=\"10525\" data-end=\"10544\"\u003eEntrance Panel:\u003c\/strong\u003e CP106 Series Aluminium Panel with Keypad\u003c\/li\u003e\n\u003cli data-section-id=\"12bd56e\" data-start=\"10586\" data-end=\"10625\"\u003e\n\u003cstrong data-start=\"10588\" data-end=\"10604\"\u003eSpeech Unit:\u003c\/strong\u003e Bell System Model 61\u003c\/li\u003e\n\u003cli data-section-id=\"1j2kdje\" data-start=\"10626\" data-end=\"10662\"\u003e\n\u003cstrong data-start=\"10628\" data-end=\"10645\"\u003ePower Supply:\u003c\/strong\u003e Bell System PS4A\u003c\/li\u003e\n\u003cli data-section-id=\"n9boj7\" data-start=\"10663\" data-end=\"10696\"\u003e\n\u003cstrong data-start=\"10665\" data-end=\"10689\"\u003ePower Supply Output:\u003c\/strong\u003e 12V DC\u003c\/li\u003e\n\u003cli data-section-id=\"1ajrej0\" data-start=\"10697\" data-end=\"10726\"\u003e\n\u003cstrong data-start=\"10699\" data-end=\"10723\"\u003ePower Supply Rating:\u003c\/strong\u003e 4A\u003c\/li\u003e\n\u003cli data-section-id=\"1e70418\" data-start=\"10727\" data-end=\"10768\"\u003e\n\u003cstrong data-start=\"10729\" data-end=\"10746\"\u003eLock Release:\u003c\/strong\u003e Bell System Model 203\u003c\/li\u003e\n\u003cli data-section-id=\"1rpodh9\" data-start=\"10769\" data-end=\"10801\"\u003e\n\u003cstrong data-start=\"10771\" data-end=\"10793\"\u003eLock Release Type:\u003c\/strong\u003e Surface\u003c\/li\u003e\n\u003cli data-section-id=\"qokdop\" data-start=\"10802\" data-end=\"10838\"\u003e\n\u003cstrong data-start=\"10804\" data-end=\"10820\"\u003eProgramming:\u003c\/strong\u003e User Programmable\u003c\/li\u003e\n\u003cli data-section-id=\"3cgwjr\" data-start=\"10839\" data-end=\"10881\"\u003e\n\u003cstrong data-start=\"10841\" data-end=\"10857\"\u003eSystem Type:\u003c\/strong\u003e Standalone Coded Access\u003c\/li\u003e\n\u003cli data-section-id=\"diuy65\" data-start=\"10882\" data-end=\"10923\"\u003e\n\u003cstrong data-start=\"10884\" data-end=\"10914\"\u003eInstallation Instructions:\u003c\/strong\u003e Included\u003c\/li\u003e\n\u003cli data-section-id=\"nnlyvs\" data-start=\"10924\" data-end=\"10964\"\u003e\n\u003cstrong data-start=\"10926\" data-end=\"10955\"\u003eProgramming Instructions:\u003c\/strong\u003e Included\u003c\/li\u003e\n\u003cli data-section-id=\"ga1d9d\" data-start=\"10965\" data-end=\"11032\"\u003e\n\u003cstrong data-start=\"10967\" data-end=\"10992\"\u003eSecurity Application:\u003c\/strong\u003e Basic Coded Access \u0026amp; Visitor Door Entry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"11cc03h\" dir=\"auto\" data-start=\"11034\" data-end=\"11058\"\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul data-start=\"11060\" data-end=\"11553\"\u003e\n\u003cli data-section-id=\"1p0ht77\" data-start=\"11060\" data-end=\"11082\"\u003eSix-Flat Conversions\u003c\/li\u003e\n\u003cli data-section-id=\"1fe2joy\" data-start=\"11083\" data-end=\"11116\"\u003eSix-Unit Residential Properties\u003c\/li\u003e\n\u003cli data-section-id=\"ds9l1y\" data-start=\"11117\" data-end=\"11144\"\u003eSmall Apartment Buildings\u003c\/li\u003e\n\u003cli data-section-id=\"25i11g\" data-start=\"11145\" data-end=\"11175\"\u003eShared Residential Entrances\u003c\/li\u003e\n\u003cli data-section-id=\"1hyfcr6\" data-start=\"11176\" data-end=\"11204\"\u003eMulti-Occupancy Properties\u003c\/li\u003e\n\u003cli data-section-id=\"13lctdx\" data-start=\"11205\" data-end=\"11225\"\u003eCommunal Entrances\u003c\/li\u003e\n\u003cli data-section-id=\"1s9sktg\" data-start=\"11226\" data-end=\"11241\"\u003eSmall Offices\u003c\/li\u003e\n\u003cli data-section-id=\"w2yodl\" data-start=\"11242\" data-end=\"11266\"\u003eMulti-Office Buildings\u003c\/li\u003e\n\u003cli data-section-id=\"ui9cch\" data-start=\"11267\" data-end=\"11285\"\u003eCommercial Units\u003c\/li\u003e\n\u003cli data-section-id=\"1sqrrwe\" data-start=\"11286\" data-end=\"11297\"\u003eWorkshops\u003c\/li\u003e\n\u003cli data-section-id=\"198t3kd\" data-start=\"11298\" data-end=\"11325\"\u003eSmall Commercial Premises\u003c\/li\u003e\n\u003cli data-section-id=\"avgg55\" data-start=\"11326\" data-end=\"11343\"\u003eStaff Entrances\u003c\/li\u003e\n\u003cli data-section-id=\"1txazo5\" data-start=\"11344\" data-end=\"11366\"\u003eControlled Entrances\u003c\/li\u003e\n\u003cli data-section-id=\"tomxl2\" data-start=\"11367\" data-end=\"11390\"\u003eVisitor Entry Systems\u003c\/li\u003e\n\u003cli data-section-id=\"4yeiiz\" data-start=\"11391\" data-end=\"11419\"\u003eKeyless Entry Applications\u003c\/li\u003e\n\u003cli data-section-id=\"22r37g\" data-start=\"11420\" data-end=\"11438\"\u003eAudio Door Entry\u003c\/li\u003e\n\u003cli data-section-id=\"1q2qg9x\" data-start=\"11439\" data-end=\"11453\"\u003eCoded Access\u003c\/li\u003e\n\u003cli data-section-id=\"1pcaifc\" data-start=\"11454\" data-end=\"11490\"\u003eSurface-Mounted Door Entry Systems\u003c\/li\u003e\n\u003cli data-section-id=\"hf2r7d\" data-start=\"11491\" data-end=\"11519\"\u003eResidential Access Control\u003c\/li\u003e\n\u003cli data-section-id=\"16p0ch5\" data-start=\"11520\" data-end=\"11553\"\u003eLight Commercial Access Control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"12hs2iu\" dir=\"auto\" data-start=\"11555\" data-end=\"11593\"\u003eWhy Choose the Bell System CS106-6?\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"11595\" data-end=\"11745\"\u003eThe \u003cstrong data-start=\"11599\" data-end=\"11622\"\u003eBell System CS106-6\u003c\/strong\u003e provides a practical way to combine \u003cstrong data-start=\"11659\" data-end=\"11723\"\u003esix-way audio visitor communication with coded keyless entry\u003c\/strong\u003e at a shared entrance.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"11747\" data-end=\"11921\"\u003eSix \u003cstrong data-start=\"11751\" data-end=\"11781\"\u003eBell System 801 telephones\u003c\/strong\u003e provide individual internal communication points, allowing each occupant to speak with visitors before operating the electric door release.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"11923\" data-end=\"12117\"\u003eFor regular users, the integrated C106 keypad provides convenient coded entry and supports \u003cstrong data-start=\"12014\" data-end=\"12046\"\u003eup to 10 unique access codes\u003c\/strong\u003e, giving the system flexibility beyond its six internal call positions.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"12119\" data-end=\"12286\"\u003eA \u003cstrong data-start=\"12121\" data-end=\"12159\"\u003eprogrammable lock-release duration\u003c\/strong\u003e provides controlled door operation, while the red and green LED indicators give users immediate feedback when entering a code.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"12288\" data-end=\"12504\"\u003eThe kit also includes the \u003cstrong data-start=\"12314\" data-end=\"12440\"\u003ealuminium keypad entrance panel, Bell model 61 speech unit, PS4A 12V 4A DC power supply and model 203 surface lock release\u003c\/strong\u003e, providing the principal equipment needed for the installation.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"12506\" data-end=\"12761\"\u003eFor \u003cstrong data-start=\"12510\" data-end=\"12616\"\u003esix-flat conversions, small apartment buildings, communal entrances and suitable commercial properties\u003c\/strong\u003e, the Bell System CS106-6 provides a straightforward combination of visitor communication, coded access and electrically controlled door release.\u003c\/p\u003e","brand":"Bell System","offers":[{"title":"Default Title","offer_id":54886216892762,"sku":"CS106-6","price":549.71,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/cs106-6-handset-door-entry_eqc4h9iig3ufd1qd.jpg?v=1790774106","url":"https:\/\/account.alertelectrical.com\/products\/bell-system-cs106-6-6-way-coded-door-entry-kit-surface","provider":"Alert Electrical","version":"1.0","type":"link"}