{"product_id":"click-mode-3-pole-fan-isolation-plate-keyswitch-with-lockable-13a-fuse-polar-white-cma10347l","title":"Click Mode 3 Pole Fan Isolation Plate Keyswitch with Lockable 13A Fuse Polar White | CMA10347L","description":"\u003ch1\u003e\u003cspan\u003eClick Mode 3 Pole Fan Isolation Plate Keyswitch with Lockable 13A Fuse – Polar White | CMA10347L\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eTriple-Pole Key-Operated Fan Isolator with Lockable Fused Connection Unit\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eClick Mode CMA10347L 3 Pole Fan Isolation Plate Keyswitch with Lockable 13A Fuse\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a practical electrical wiring accessory designed to provide controlled isolation and fused protection for suitable ventilation and extractor fan installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eManufactured by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eClick Scolmore\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this specialist fan isolation accessory combines a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etriple-pole key-operated isolation switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elockable fuse drawer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing a convenient solution for installations where access to the isolation control needs to be restricted.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePart of the popular \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eClick Mode range\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the CMA10347L features a contemporary \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003epolar white moulded faceplate\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with a smooth profile, making it suitable for domestic, commercial and managed-property electrical installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe integrated \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-pole keyswitch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is designed to isolate three conductors simultaneously, making it particularly useful for appropriately wired extractor fans incorporating permanent live, switched live and neutral connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eUnlike a conventional rocker-operated fan isolator, the key-operated mechanism helps restrict operation to authorised personnel with the appropriate key.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe accessory also incorporates a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elockable fuse drawer fitted with a 13A fuse\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing a dedicated fused connection arrangement within the same faceplate.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis combination is particularly useful in managed buildings, commercial premises and residential properties where maintenance access and control of ventilation equipment are important considerations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRated at \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e250V AC\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the Click CMA10347L is suitable for compatible fixed wiring installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe accessory features an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e86mm × 86mm faceplate\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, a depth of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e9.5mm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, standard \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e60.3mm fixing centres\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and a minimum back box depth of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e25mm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIts smooth polar white finish coordinates with other accessories in the Click Mode range, helping maintain a consistent appearance throughout a property.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWhether installing a new extractor fan, upgrading an existing ventilation circuit or specifying controlled isolation for a managed building, the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eClick Mode CMA10347L Fan Isolation Keyswitch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides a practical and professional solution.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eClick Mode 3 Pole Fan Isolation Plate Keyswitch\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eManufacturer Part Number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e CMA10347L\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBrand:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Click Scolmore\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eProduct Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Mode\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Triple-Pole Fan Isolation Keyswitch with Fused Connection\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eSwitch Configuration:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 3 Pole\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eSwitch Operation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Key-Operated\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFuse Drawer:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Lockable\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFuse Fitted:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 13A\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eRated Voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 250V AC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFinish:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Polar White\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFaceplate Style:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Smooth Profile\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDurable moulded faceplate construction\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eContemporary appearance\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDesigned for suitable extractor fan installations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProvides triple-pole isolation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHelps restrict unauthorised switching\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIntegrated fused connection arrangement\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for appropriate fixed wiring circuits\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePlate Dimensions:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 86mm W × 86mm H × 9.5mm D\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFixing Centres:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 60.3mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMinimum Back Box Depth:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 25mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eSwitch Terminal Capacity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 4 × 1.5mm² or 2 × 2.5mm²\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFuse Module Terminal Capacity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 3 × 2.5mm² or 2 × 4.0mm²\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOperating Temperature:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e -5°C to +40°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for domestic and commercial ventilation installations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCoordinates with Click Mode polar white wiring accessories\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDesigned for professional electrical installation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eTriple-Pole Fan Isolation\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eClick CMA10347L\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e incorporates a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ethree-pole isolation switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e designed for compatible fan circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eMany extractor fans, particularly timer-controlled models, require connections for permanent live, switched live and neutral conductors.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA suitable triple-pole isolator allows these three conductors to be disconnected together when maintenance or servicing is required.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eBenefits of Triple-Pole Isolation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eSimultaneous switching of three conductors\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for appropriately wired timer extractor fans\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePractical for ventilation maintenance\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSupports controlled electrical isolation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConvenient for professional servicing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for domestic and commercial installations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHelps simplify maintenance arrangements\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe triple-pole configuration makes the CMA10347L particularly useful for ventilation systems where a conventional single-pole switch would not provide the required isolation arrangement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eImportant:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The correct conductors must be connected according to the fan manufacturer's instructions and the electrical circuit design. The protective earth conductor must not be switched.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eKey-Operated Isolation Switch\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA key feature of the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eClick Mode CMA10347L\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is its \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ekey-operated switching mechanism\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eUnlike a standard fan isolator with a manually operated rocker switch, the keyswitch requires the appropriate operating key.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis helps restrict casual or unauthorised operation of the isolation switch.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eBenefits of Key-Operated Switching\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eHelps restrict unauthorised switching\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for managed buildings\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePractical for maintenance-controlled installations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReduces casual interference with ventilation controls\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUseful in commercial premises\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for shared residential environments\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProvides a dedicated method of operating the fan isolator\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe key-operated design can be particularly beneficial where ventilation equipment should remain operational during normal building use.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eSafety Note:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e A key-operated switch should not automatically be treated as a secure lock-off device for electrical maintenance. Safe isolation must be carried out using an appropriate procedure, including verification that the circuit is dead.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eLockable 13A Fuse Drawer\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eClick CMA10347L\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e incorporates a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elockable fuse drawer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e fitted with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e13A fuse\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis provides a fused connection arrangement alongside the triple-pole keyswitch.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe lockable drawer helps restrict access to the fuse compartment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eBenefits of the Lockable Fuse Drawer\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eIntegrated fused connection arrangement\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSupplied with a 13A fuse\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLockable fuse access\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePractical for managed electrical installations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConvenient for maintenance personnel\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCombines isolation and fused connection functions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReduces the need for separate faceplate accessories in suitable installations\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe fuse drawer is intended to accommodate an appropriate fuse for the connected circuit and equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eImportant Fuse Selection Information\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAlthough the CMA10347L is supplied with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e13A fuse\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this does not mean every extractor fan should be protected by a 13A fuse.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eMany ventilation appliances require a lower-rated fuse.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe installed fuse rating must be selected according to the fan manufacturer's instructions, cable protection requirements and electrical circuit design.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eThe supplied 13A fuse should be replaced with the correct rating where required by the connected equipment.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eIdeal for Timer-Controlled Extractor Fans\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eClick Mode CMA10347L\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is particularly useful for suitable timer-controlled extractor fan installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eTimer fans commonly require separate permanent live and switched live supplies to allow the fan to continue operating for a preset period after the room light has been switched off.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA correctly connected triple-pole isolator can disconnect the relevant supply conductors for maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eTypical Fan Applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eBathroom extractor fans\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eToilet extractor fans\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEn-suite ventilation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUtility room extractor fans\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTimer-controlled ventilation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCommercial washroom extraction\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eResidential ventilation systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable intermittent extract fans\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eCompatibility must be confirmed against the ventilation manufacturer's wiring diagram.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eSmooth Profile Polar White Finish\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eClick Mode CMA10347L\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e features a smooth-profile moulded faceplate finished in \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003epolar white\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis clean, contemporary appearance makes it suitable for a wide variety of interior environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe neutral white finish coordinates with other electrical accessories in the Click Mode range.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eBenefits of the Polar White Finish\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eClean contemporary appearance\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSmooth moulded faceplate\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for domestic interiors\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePractical for commercial premises\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCoordinates with white switches and sockets\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for refurbishment projects\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eComplements modern electrical installations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEasy to incorporate into existing decorative schemes\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe moulded plate provides a practical alternative to decorative metal wiring accessories where a simple, professional appearance is preferred.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eCompact Single-Gang Faceplate Design\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eClick CMA10347L\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is designed around a standard single-gang faceplate format.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIts compact dimensions allow it to be incorporated into suitable wall-mounted electrical installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eFaceplate Dimensions\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWidth:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 86mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 86mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDepth:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 9.5mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFixing Centres:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 60.3mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMinimum Back Box Depth:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 25mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eInstallation Benefits\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eStandard single-gang faceplate dimensions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompact wall-mounted design\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for appropriate flush-mounted installations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStandard fixing-centre arrangement\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCoordinates with other Click Mode accessories\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePractical for replacement and refurbishment work\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eImportant:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Although the manufacturer's minimum back box depth is 25mm, the actual installation must provide sufficient space for the conductors, terminations and safe cable routing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA deeper back box may be preferable where additional wiring space is required.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eSuitable for Domestic Ventilation Installations\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eClick Mode CMA10347L\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is suitable for a range of domestic ventilation applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIts triple-pole switching and integrated fuse module make it a practical option for appropriate extractor fan circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eResidential Applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eBathrooms\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEn-suites\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eToilets\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUtility rooms\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eResidential refurbishments\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNew-build homes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eApartment buildings\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eManaged residential properties\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDomestic ventilation upgrades\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe key-operated design is particularly useful where the fan isolator should not be operated casually.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eImportant:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Installation within bathrooms or other locations subject to special electrical requirements must comply with the applicable wiring regulations and permitted installation zones.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eSuitable for Commercial and Managed Buildings\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eClick CMA10347L\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is also suitable for commercial environments where ventilation equipment requires controlled isolation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCommercial Applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eOffices\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCommercial washrooms\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRetail premises\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eManaged accommodation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eApartment communal areas\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHospitality premises\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStaff facilities\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCommercial property refurbishments\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance-controlled ventilation systems\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe keyswitch provides an additional level of operational control compared with a standard rocker-operated isolator.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe lockable fuse drawer also helps manage access to the fused connection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003ePart of the Click Mode Wiring Accessories Range\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCMA10347L\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e forms part of the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eClick Mode range\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e of moulded wiring accessories.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eClick Mode products are designed to provide practical electrical solutions with a coordinated polar white finish.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe range includes a variety of switches, socket outlets, fused connection units and specialist wiring accessories.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eBenefits of the Click Mode Range\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eContemporary smooth-profile design\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePolar white finish\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCoordinated electrical accessories\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for domestic installations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePractical for commercial properties\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWide range of wiring accessory functions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDesigned for professional electrical installation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eChoosing matching Click Mode accessories helps maintain a consistent appearance throughout an electrical installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eDesigned for Professional Electrical Installation\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eClick Mode CMA10347L\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e incorporates separate terminal arrangements for the triple-pole switch and fuse module.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThese terminal capacities must be considered when selecting cables and planning the installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSwitch Terminal Capacity\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e4 × 1.5mm²\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eOr 2 × 2.5mm²\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eFuse Module Terminal Capacity\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e3 × 2.5mm²\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eOr 2 × 4.0mm²\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eInstallation Considerations\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eConfirm compatibility with the connected fan\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFollow the fan manufacturer's wiring diagram\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIdentify permanent live, switched live and neutral conductors correctly\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintain protective earth continuity\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSelect the correct fuse rating\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUse appropriate cable sizes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eObserve terminal capacity limits\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProvide adequate back box space\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVerify the operation of the triple-pole switch\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCheck the lockable fuse drawer\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eComplete the required electrical testing\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eImportant Installation Guidance\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe CMA10347L must be installed in accordance with:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eThe manufacturer's installation instructions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCurrent BS 7671 wiring regulations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThe ventilation equipment manufacturer's requirements\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eApplicable circuit protection requirements\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCorrect electrical isolation procedures\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRelevant building and electrical safety regulations\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInstallation should be undertaken by a suitably qualified or competent electrical professional.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eGeneral Product Information\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBrand:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Click Scolmore\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eManufacturer:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Scolmore International\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eProduct Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Mode\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eManufacturer Part Number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e CMA10347L\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eProduct Name:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 3 Pole Fan Isolation Plate Keyswitch with Lockable 13A Fuse\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Fan Isolation Keyswitch with Fused Connection\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAccessory Category:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Wiring Accessories\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eSwitch Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Triple Pole\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOperation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Key-Operated\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFuse Drawer:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Lockable\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFaceplate Colour:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Polar White\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFaceplate Style:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Smooth Profile\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePlate Material:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Moulded Insulating Material\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eElectrical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eRated Voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 250V AC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eNumber of Poles:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 3\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eSwitching Arrangement:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Triple-Pole Switched\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eSwitch Operation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Keyswitch\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFuse Fitted:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 13A\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFuse Module:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Integrated\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFuse Drawer:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Lockable\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eSuitable Circuit Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Compatible Fixed Wiring Fan Circuits\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eSwitch Current Rating:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Confirm Against Manufacturer's Technical Data\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFuse Rating Supplied:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 13A\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eSwitch Terminal Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTerminal Capacity Option 1:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 4 × 1.5mm²\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTerminal Capacity Option 2:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 2 × 2.5mm²\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eFuse Module Terminal Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTerminal Capacity Option 1:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 3 × 2.5mm²\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTerminal Capacity Option 2:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 2 × 4.0mm²\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eFaceplate Dimensions\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWidth:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 86mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 86mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDepth:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 9.5mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFixing Centres:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 60.3mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFaceplate Format:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Single Gang\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eProfile:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Smooth\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eInstallation Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMounting Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Wall Mounted\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMinimum Back Box Depth:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 25mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFixing Centres:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 60.3mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTerminal Arrangement:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Separate Switch and Fuse Module Terminals\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eElectrical Connection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Fixed Wiring\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBack Box Included:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Not Specified\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOperating Key Included:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Not Confirmed\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eEnvironmental Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMinimum Operating Temperature:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e -5°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMaximum Operating Temperature:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e +40°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOperating Temperature Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e -5°C to +40°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eIP Rating:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Not Specified\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOutdoor Suitability:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Not Confirmed\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eAdditional Information\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eManufacturer Part Number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e CMA10347L\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBrand:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Click Scolmore\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eRange:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Mode\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eColour:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Polar White\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eSwitch Configuration:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 3 Pole\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eKeyswitch:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Yes\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eLockable Fuse Drawer:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Yes\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFuse Fitted:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 13A\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePlate Dimensions:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 86 × 86 × 9.5mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMinimum Back Box Depth:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 25mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eManufacturer Warranty:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Confirm Current Click Scolmore Warranty Terms\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eSuitable Applications\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eClick Mode CMA10347L 3 Pole Fan Isolation Keyswitch with Lockable 13A Fuse\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is suitable for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eBathroom Extractor Fans\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEn-Suite Extractor Fans\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eToilet Extractor Fans\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTimer-Controlled Fans\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUtility Room Ventilation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDomestic Ventilation Systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCommercial Washroom Ventilation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOffice Ventilation Installations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eManaged Residential Properties\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eApartment Buildings\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCommercial Buildings\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eResidential Refurbishments\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNew-Build Properties\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eExtractor Fan Replacements\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVentilation Maintenance Installations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eKey-Operated Fan Isolation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFused Fan Connection Arrangements\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProfessional Electrical Installations\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cem\u003e\u003cspan\u003eAll applications are subject to the connected equipment's requirements and the electrical installation design.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eWhy Choose the Click Mode CMA10347L?\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eClick Mode CMA10347L 3 Pole Fan Isolation Plate Keyswitch with Lockable 13A Fuse\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides a practical combination of controlled isolation, fused connection functionality and contemporary styling.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIts \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etriple-pole switching arrangement\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e makes it suitable for appropriately wired ventilation circuits requiring simultaneous disconnection of three conductors.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ekey-operated mechanism\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e helps restrict unauthorised operation, making the accessory particularly useful in managed buildings and commercial installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe integrated \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elockable fuse drawer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides a dedicated fused connection arrangement, with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e13A fuse supplied\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFinished in \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003epolar white\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the smooth-profile moulded faceplate coordinates with other Click Mode electrical accessories.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compact \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e86mm × 86mm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e plate and standard \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e60.3mm fixing centres\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e support installation in suitable single-gang mounting arrangements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWith clearly specified switch and fuse module terminal capacities, the CMA10347L is designed for professional electrical installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhether installing a new extractor fan or upgrading an existing ventilation system, the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eClick Mode CMA10347L\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e offers a practical solution for controlled fan isolation and fused connection requirements.\u003c\/span\u003e\u003c\/p\u003e","brand":"Click Mode","offers":[{"title":"Default Title","offer_id":55092370145626,"sku":"CMA10347L","price":13.64,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/CMA10347L.png?v=1793173410","url":"https:\/\/account.alertelectrical.com\/products\/click-mode-3-pole-fan-isolation-plate-keyswitch-with-lockable-13a-fuse-polar-white-cma10347l","provider":"Alert Electrical","version":"1.0","type":"link"}