{"product_id":"fusebox-10a-30ma-type-a-b-curve-6ka-bi-directional-mini-rcbo-rtamb10bd","title":"FuseBox 10A 30mA Type A B Curve 6kA Bi-Directional Mini RCBO | RTAMB10BD","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eFuseBox 10A 30mA Type A B Curve 6kA Bi-Directional Mini RCBO | RTAMB10BD\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2\u003e10A Bi-Directional Type A Mini RCBO for FuseBox Consumer Units\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTAMB10BD\u003c\/strong\u003e is a compact \u003cstrong\u003e10A 30mA Type A bi-directional mini RCBO\u003c\/strong\u003e designed to provide combined residual current and overcurrent protection for individual circuits within compatible FuseBox consumer units.\u003c\/p\u003e\n\u003cp\u003eFeaturing a \u003cstrong\u003eB Curve tripping characteristic, 6kA short-circuit breaking capacity and 1P+N switched configuration\u003c\/strong\u003e, the RTAMB10BD protects against \u003cstrong\u003eoverloads, short circuits and residual current \/ earth leakage faults\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIts \u003cstrong\u003ebi-directional design\u003c\/strong\u003e allows the device to operate where current may flow in either direction, making it particularly relevant to modern electrical installations, including appropriate \u003cstrong\u003esolar PV and renewable energy applications\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e10A Rated Current\u003c\/li\u003e\n\u003cli\u003e30mA Residual Operating Current\u003c\/li\u003e\n\u003cli\u003eType A Residual Current Protection\u003c\/li\u003e\n\u003cli\u003eBi-Directional Operation\u003c\/li\u003e\n\u003cli\u003eB Curve Tripping Characteristic\u003c\/li\u003e\n\u003cli\u003e6kA Short-Circuit Breaking Capacity\u003c\/li\u003e\n\u003cli\u003eCombined RCD \u0026amp; MCB Protection\u003c\/li\u003e\n\u003cli\u003eProtects Against Overloads\u003c\/li\u003e\n\u003cli\u003eProtects Against Short Circuits\u003c\/li\u003e\n\u003cli\u003eProtects Against Earth Leakage Faults\u003c\/li\u003e\n\u003cli\u003eDetects AC \u0026amp; Pulsating DC Residual Currents\u003c\/li\u003e\n\u003cli\u003eSuitable Where Current May Flow in Either Direction\u003c\/li\u003e\n\u003cli\u003eSuitable for Appropriate Solar PV Applications\u003c\/li\u003e\n\u003cli\u003e1P + N Switched Configuration\u003c\/li\u003e\n\u003cli\u003eLine \u0026amp; Neutral Switched\u003c\/li\u003e\n\u003cli\u003eCompact Mini RCBO Design\u003c\/li\u003e\n\u003cli\u003eSingle Module Width\u003c\/li\u003e\n\u003cli\u003e230V AC Rated Voltage\u003c\/li\u003e\n\u003cli\u003e50\/60Hz Operation\u003c\/li\u003e\n\u003cli\u003eIP20 Protection\u003c\/li\u003e\n\u003cli\u003e35mm DIN Rail Mounting\u003c\/li\u003e\n\u003cli\u003eDesigned for Compatible FuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eIEC 61009-1 \u0026amp; IEC 61009-2-2 Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBi-Directional Circuit Protection\u003c\/h2\u003e\n\u003cp\u003eA key feature of the \u003cstrong\u003eFuseBox RTAMB10BD\u003c\/strong\u003e is its \u003cstrong\u003ebi-directional operation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eBi-directional protective devices are designed for installations where electrical current may flow in either direction. This is increasingly important in electrical systems incorporating generation technologies such as \u003cstrong\u003esolar PV\u003c\/strong\u003e, where electricity can be supplied back through parts of the installation.\u003c\/p\u003e\n\u003cp\u003eThe RTAMB10BD therefore provides a modern circuit protection option for appropriately designed installations requiring a \u003cstrong\u003e10A bi-directional RCBO\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eCombined RCBO Protection\u003c\/h2\u003e\n\u003cp\u003eThe RTAMB10BD combines the functionality of an \u003cstrong\u003eMCB and RCD within one device\u003c\/strong\u003e, providing protection against:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOverloads\u003c\/li\u003e\n\u003cli\u003eShort Circuits\u003c\/li\u003e\n\u003cli\u003eResidual Current \/ Earth Leakage Faults\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProviding each outgoing circuit with dedicated RCBO protection can also improve circuit separation compared with arrangements where several circuits share a single RCD.\u003c\/p\u003e\n\u003ch2\u003e30mA Type A Residual Current Protection\u003c\/h2\u003e\n\u003cp\u003eThe RTAMB10BD provides \u003cstrong\u003e30mA Type A residual current protection\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eType A RCBOs are designed to detect both \u003cstrong\u003esinusoidal AC and pulsating DC residual currents\u003c\/strong\u003e, making them particularly relevant to modern installations incorporating electronic equipment.\u003c\/p\u003e\n\u003cp\u003eThe 30mA residual operating current provides additional protection for appropriately designed final circuits.\u003c\/p\u003e\n\u003ch2\u003e10A B Curve Protection\u003c\/h2\u003e\n\u003cp\u003eThis model has a rated current of \u003cstrong\u003e10A\u003c\/strong\u003e and uses a \u003cstrong\u003eB Curve tripping characteristic\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe 10A rating makes it suitable for appropriately designed circuits requiring this level of overcurrent protection, while the B Curve characteristic is commonly used for circuits with relatively low inrush currents.\u003c\/p\u003e\n\u003cp\u003eCorrect protective device selection should always take account of the circuit load, cable size, installation method and applicable wiring requirements.\u003c\/p\u003e\n\u003ch2\u003e6kA Short-Circuit Breaking Capacity\u003c\/h2\u003e\n\u003cp\u003eThe FuseBox RTAMB10BD has a rated short-circuit breaking capacity of \u003cstrong\u003e6000A \/ 6kA\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis allows the RCBO to provide short-circuit protection within electrical installations where a 6kA rated protective device is appropriate.\u003c\/p\u003e\n\u003ch2\u003eCompact 1P+N Switched Design\u003c\/h2\u003e\n\u003cp\u003eThe RTAMB10BD uses a compact \u003cstrong\u003e1P+N switched configuration\u003c\/strong\u003e, providing switching of both the line and neutral.\u003c\/p\u003e\n\u003cp\u003eDespite combining overcurrent protection, residual current protection and switched-neutral functionality, the device occupies just \u003cstrong\u003eone module\u003c\/strong\u003e within the consumer unit.\u003c\/p\u003e\n\u003cp\u003eIts compact mini RCBO construction helps maximise available wiring and working space, particularly where multiple circuits require individual RCBO protection.\u003c\/p\u003e\n\u003ch2\u003eIdeal for Modern \u0026amp; Renewable Energy Installations\u003c\/h2\u003e\n\u003cp\u003eElectrical installations are increasingly incorporating technologies that can change the traditional direction of power flow.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003ebi-directional design\u003c\/strong\u003e of the RTAMB10BD makes it particularly useful for appropriately designed systems involving renewable generation or other applications where power may flow in either direction through the protective device.\u003c\/p\u003e\n\u003cp\u003eThis makes the FuseBox RTAMB range a versatile option when designing modern consumer unit installations.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e FuseBox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Code:\u003c\/strong\u003e RTAMB10BD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Bi-Directional Mini RCBO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 10A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Residual Operating Current:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCD Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperation:\u003c\/strong\u003e Bi-Directional\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristic:\u003c\/strong\u003e B Curve, 3–5 In\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Breaking Capacity:\u003c\/strong\u003e 6000A \/ 6kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 1P + N Switched\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine \u0026amp; Neutral Switching:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 230V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Rating:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Modules:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e 35mm DIN Rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Incoming Terminal Capacity:\u003c\/strong\u003e 16mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Outgoing Terminal Capacity:\u003c\/strong\u003e 10mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncoming Recommended Tightening Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutgoing Recommended Tightening Torque:\u003c\/strong\u003e 1.2Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNeutral Cable CSA:\u003c\/strong\u003e 2.5mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Endurance:\u003c\/strong\u003e 10,000 Operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e PA6 \/ Nylon 6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e Approx. 85 x 18 x 69.5mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e IEC 61009-1, IEC 61009-2-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eDomestic Electrical Installations\u003c\/li\u003e\n\u003cli\u003eAppropriate 10A Final Circuits\u003c\/li\u003e\n\u003cli\u003eSolar PV Installations\u003c\/li\u003e\n\u003cli\u003eRenewable Energy Systems\u003c\/li\u003e\n\u003cli\u003eApplications with Bi-Directional Current Flow\u003c\/li\u003e\n\u003cli\u003eResidential Properties\u003c\/li\u003e\n\u003cli\u003eNew-Build Electrical Installations\u003c\/li\u003e\n\u003cli\u003eConsumer Unit Upgrades\u003c\/li\u003e\n\u003cli\u003eIndividual Circuit Protection\u003c\/li\u003e\n\u003cli\u003eAppropriate Light Commercial Installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose the FuseBox RTAMB10BD?\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTAMB10BD\u003c\/strong\u003e combines \u003cstrong\u003e10A overcurrent protection, 30mA Type A residual current protection and bi-directional capability\u003c\/strong\u003e within a compact single-module device.\u003c\/p\u003e\n\u003cp\u003eIts \u003cstrong\u003ebi-directional design\u003c\/strong\u003e makes it particularly relevant to modern electrical installations where power can flow in either direction, including appropriate solar PV and renewable energy applications.\u003c\/p\u003e\n\u003cp\u003eWith a \u003cstrong\u003eB Curve characteristic, 6kA breaking capacity and 1P+N switched configuration\u003c\/strong\u003e, the RTAMB10BD provides comprehensive individual circuit protection while making efficient use of available consumer unit space.\u003c\/p\u003e","brand":"FuseBox Consumer Units \u0026 Circuit Protection","offers":[{"title":"Default Title","offer_id":54694349373786,"sku":"RTAMB10BD","price":24.02,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/RTAMB_10_BD_ANGLE_243e6d9d95.webp?v=1788437980","url":"https:\/\/account.alertelectrical.com\/products\/fusebox-10a-30ma-type-a-b-curve-6ka-bi-directional-mini-rcbo-rtamb10bd","provider":"Alert Electrical","version":"1.0","type":"link"}