{"product_id":"fusebox-20a-30ma-type-a-b-curve-6ka-rcbo-rta062030b","title":"FuseBox 20A 30mA Type A B Curve 6kA RCBO | RTA062030B","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eFuseBox 20A 30mA Type A B Curve 6kA RCBO | RTA062030B\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2\u003e20A Single Module Type A RCBO for FuseBox Consumer Units\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTA062030B\u003c\/strong\u003e is a \u003cstrong\u003e20A 30mA Type A B Curve RCBO\u003c\/strong\u003e designed to provide combined residual current and overcurrent protection for individual circuits within compatible FuseBox consumer units.\u003c\/p\u003e\n\u003cp\u003eCombining the functions of an \u003cstrong\u003eMCB and RCD in one compact protective device\u003c\/strong\u003e, the RTA062030B protects against \u003cstrong\u003eoverloads, short circuits and residual current \/ earth leakage faults\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eWith a \u003cstrong\u003e20A rated current, 30mA residual operating current, Type A characteristics, B Curve tripping and 6kA breaking capacity\u003c\/strong\u003e, it provides comprehensive circuit protection while occupying just a single module within the consumer unit.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e20A Rated Current\u003c\/li\u003e\n\u003cli\u003e30mA Residual Operating Current\u003c\/li\u003e\n\u003cli\u003eType A Residual Current Protection\u003c\/li\u003e\n\u003cli\u003eB Curve Tripping Characteristic\u003c\/li\u003e\n\u003cli\u003e6kA Short-Circuit Breaking Capacity\u003c\/li\u003e\n\u003cli\u003eCombined RCD \u0026amp; MCB Protection\u003c\/li\u003e\n\u003cli\u003eProtects Against Earth Leakage Faults\u003c\/li\u003e\n\u003cli\u003eProtects Against Overloads\u003c\/li\u003e\n\u003cli\u003eProtects Against Short Circuits\u003c\/li\u003e\n\u003cli\u003eType A Detection for AC \u0026amp; Pulsating DC Residual Currents\u003c\/li\u003e\n\u003cli\u003e1P + N Configuration\u003c\/li\u003e\n\u003cli\u003eCompact Single Module Design\u003c\/li\u003e\n\u003cli\u003e230V AC Rated Voltage\u003c\/li\u003e\n\u003cli\u003e50\/60Hz Operation\u003c\/li\u003e\n\u003cli\u003eIP20 Protection\u003c\/li\u003e\n\u003cli\u003e35mm DIN Rail Mounting\u003c\/li\u003e\n\u003cli\u003eFlying Neutral Connection\u003c\/li\u003e\n\u003cli\u003eDesigned for FuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eManufactured to IEC\/EN 61009-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCombined RCBO Protection\u003c\/h2\u003e\n\u003cp\u003eAn RCBO combines \u003cstrong\u003eovercurrent protection and residual current protection\u003c\/strong\u003e within a single device.\u003c\/p\u003e\n\u003cp\u003eThe FuseBox RTA062030B therefore provides protection against:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOverloads\u003c\/li\u003e\n\u003cli\u003eShort Circuits\u003c\/li\u003e\n\u003cli\u003eResidual Current \/ Earth Leakage Faults\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUsing individual RCBOs also allows protection to be provided on a circuit-by-circuit basis rather than several circuits sharing a single RCD.\u003c\/p\u003e\n\u003ch2\u003eType A Residual Current Protection\u003c\/h2\u003e\n\u003cp\u003eThe RTA062030B features \u003cstrong\u003eType A residual current protection\u003c\/strong\u003e, allowing it to respond to both sinusoidal AC and pulsating DC residual currents.\u003c\/p\u003e\n\u003cp\u003eThis makes Type A protection particularly relevant to modern electrical installations, where many appliances and electronic devices can produce residual current waveforms beyond purely sinusoidal AC.\u003c\/p\u003e\n\u003ch2\u003e20A B Curve Protection\u003c\/h2\u003e\n\u003cp\u003eThis model has a rated current of \u003cstrong\u003e20A\u003c\/strong\u003e and uses a \u003cstrong\u003eB Curve tripping characteristic\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe 20A rating makes it suitable for appropriately designed final circuits requiring this level of overcurrent protection.\u003c\/p\u003e\n\u003cp\u003eProtective device selection should always take account of the connected load, cable size, installation method and applicable wiring requirements.\u003c\/p\u003e\n\u003ch2\u003e6kA Short-Circuit Breaking Capacity\u003c\/h2\u003e\n\u003cp\u003eThe RTA062030B has a rated short-circuit breaking capacity of \u003cstrong\u003e6000A \/ 6kA\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis provides short-circuit protection for installations where a 6kA rated protective device is appropriate.\u003c\/p\u003e\n\u003ch2\u003eCompact Single Module Design\u003c\/h2\u003e\n\u003cp\u003eOccupying only \u003cstrong\u003eone module\u003c\/strong\u003e, the RTA062030B helps maximise the available space within a FuseBox consumer unit.\u003c\/p\u003e\n\u003cp\u003eThe RCBO is designed for mounting onto a standard \u003cstrong\u003e35mm DIN rail\u003c\/strong\u003e and incorporates a flying neutral connection for installation within the distribution board.\u003c\/p\u003e\n\u003ch2\u003eIndividual Circuit Protection\u003c\/h2\u003e\n\u003cp\u003eRCBOs provide residual current and overcurrent protection to each individual circuit.\u003c\/p\u003e\n\u003cp\u003eThis approach can improve circuit separation because an electrical fault can operate the RCBO protecting the affected circuit rather than relying on a shared RCD protecting multiple outgoing circuits.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e FuseBox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Code:\u003c\/strong\u003e RTA062030B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e RCBO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 20A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Residual Operating Current:\u003c\/strong\u003e 30mA \/ 0.03A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCD Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResidual Current Detection:\u003c\/strong\u003e AC \u0026amp; Pulsating DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristic:\u003c\/strong\u003e B Curve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Breaking Capacity:\u003c\/strong\u003e 6000A \/ 6kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 230V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Degree:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Modules:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e 35mm DIN Rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Incoming Terminal Capacity:\u003c\/strong\u003e 16mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Outgoing Terminal Capacity:\u003c\/strong\u003e 10mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncoming Recommended Tightening Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutgoing Recommended Tightening Torque:\u003c\/strong\u003e 1.2Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlying Neutral Cable Length:\u003c\/strong\u003e 450mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Endurance:\u003c\/strong\u003e 10,000 Operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e PA6 \/ Nylon 6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eDomestic Electrical Installations\u003c\/li\u003e\n\u003cli\u003eAppropriate 20A Final Circuits\u003c\/li\u003e\n\u003cli\u003eResidential Properties\u003c\/li\u003e\n\u003cli\u003eNew-Build Electrical Installations\u003c\/li\u003e\n\u003cli\u003eConsumer Unit Replacements \u0026amp; Upgrades\u003c\/li\u003e\n\u003cli\u003eCircuit Extensions\u003c\/li\u003e\n\u003cli\u003eIndividual Circuit Protection\u003c\/li\u003e\n\u003cli\u003eAppropriate Light Commercial Installations\u003c\/li\u003e\n\u003cli\u003eElectrical Distribution Upgrades\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose the FuseBox RTA062030B?\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTA062030B\u003c\/strong\u003e combines \u003cstrong\u003eoverload, short-circuit and 30mA residual current protection\u003c\/strong\u003e within one compact protective device.\u003c\/p\u003e\n\u003cp\u003eIts \u003cstrong\u003e20A rating, B Curve characteristic, Type A residual protection and 6kA breaking capacity\u003c\/strong\u003e make it a practical solution for appropriately designed circuits within FuseBox consumer units.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003esingle-module DIN rail design\u003c\/strong\u003e also makes efficient use of available consumer unit space while providing dedicated RCBO protection to the individual circuit.\u003c\/p\u003e","brand":"FuseBox Consumer Units \u0026 Circuit Protection","offers":[{"title":"Default Title","offer_id":54694296420698,"sku":"RTA062030B","price":16.04,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/RTA_060630_B_fef9b50559_1c4e17f3-dfd9-46ef-ba4e-b0daa00fbf29.webp?v=1788437132","url":"https:\/\/account.alertelectrical.com\/products\/fusebox-20a-30ma-type-a-b-curve-6ka-rcbo-rta062030b","provider":"Alert Electrical","version":"1.0","type":"link"}