{"product_id":"fusebox-40a-30ma-type-a-b-curve-6ka-rcbo-rta064030b","title":"FuseBox 40A 30mA Type A B Curve 6kA RCBO | RTA064030B","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eFuseBox 40A 30mA Type A B Curve 6kA RCBO | RTA064030B\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2\u003e40A Single Module Type A RCBO for FuseBox Consumer Units\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTA064030B\u003c\/strong\u003e is a \u003cstrong\u003e40A 30mA Type A B Curve RCBO\u003c\/strong\u003e designed to provide combined overcurrent and residual current protection for individual circuits within compatible FuseBox consumer units.\u003c\/p\u003e\n\u003cp\u003eCombining the functions of an \u003cstrong\u003eMCB and RCD within one compact device\u003c\/strong\u003e, the RTA064030B protects against \u003cstrong\u003eoverloads, short circuits and residual current \/ earth leakage faults\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eWith a \u003cstrong\u003e40A rated current, 30mA sensitivity, Type A residual current characteristics, B Curve tripping and 6kA breaking capacity\u003c\/strong\u003e, it provides comprehensive circuit protection while occupying just one module within the consumer unit. FuseBox lists the RTA064030B as the 40A model in its 6kA Type A RCBO range. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e40A Rated Current\u003c\/li\u003e\n\u003cli\u003e30mA Residual Operating Current\u003c\/li\u003e\n\u003cli\u003eType A Residual Current Protection\u003c\/li\u003e\n\u003cli\u003eB Curve Tripping Characteristic\u003c\/li\u003e\n\u003cli\u003e6kA Short-Circuit Breaking Capacity\u003c\/li\u003e\n\u003cli\u003eCombined RCD \u0026amp; MCB Protection\u003c\/li\u003e\n\u003cli\u003eProtects Against Overloads\u003c\/li\u003e\n\u003cli\u003eProtects Against Short Circuits\u003c\/li\u003e\n\u003cli\u003eProtects Against Earth Leakage Faults\u003c\/li\u003e\n\u003cli\u003eDetects AC \u0026amp; Pulsating DC Residual Currents\u003c\/li\u003e\n\u003cli\u003e1P + N Configuration\u003c\/li\u003e\n\u003cli\u003eCompact Single Module Design\u003c\/li\u003e\n\u003cli\u003e230V AC Rated Voltage\u003c\/li\u003e\n\u003cli\u003e50\/60Hz Operation\u003c\/li\u003e\n\u003cli\u003eIP20 Protection\u003c\/li\u003e\n\u003cli\u003e35mm DIN Rail Mounting\u003c\/li\u003e\n\u003cli\u003e450mm Flying Neutral Cable\u003c\/li\u003e\n\u003cli\u003e10,000 Mechanical Operations\u003c\/li\u003e\n\u003cli\u003eDesigned for FuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eManufactured to IEC\/EN 61009-1 \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCombined RCBO Circuit Protection\u003c\/h2\u003e\n\u003cp\u003eThe RTA064030B combines \u003cstrong\u003eresidual current and overcurrent protection within a single device\u003c\/strong\u003e, providing protection against three key electrical fault conditions:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOverloads\u003c\/li\u003e\n\u003cli\u003eShort Circuits\u003c\/li\u003e\n\u003cli\u003eResidual Current \/ Earth Leakage Faults\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUsing dedicated RCBOs on individual outgoing circuits can also improve circuit separation compared with arrangements where several circuits share one RCD. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eType A Residual Current Protection\u003c\/h2\u003e\n\u003cp\u003eThe RTA064030B provides \u003cstrong\u003eType A residual current protection\u003c\/strong\u003e, designed to respond to both AC and pulsating DC residual currents.\u003c\/p\u003e\n\u003cp\u003eFuseBox specifies the device's residual current characteristics as \u003cstrong\u003eType A for AC and pulsating DC up to 6mA\u003c\/strong\u003e, making it suitable for many modern electrical installations incorporating electronic loads. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e40A B Curve Protection\u003c\/h2\u003e\n\u003cp\u003eWith a rated current of \u003cstrong\u003e40A\u003c\/strong\u003e, the RTA064030B uses a \u003cstrong\u003eB Curve tripping characteristic of 3–5 In\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe 40A rating makes this model suitable for appropriately designed circuits requiring this level of overcurrent protection. Selection should always be based on the connected load, cable size, installation method and applicable electrical installation requirements.\u003c\/p\u003e\n\u003ch2\u003e6kA Short-Circuit Breaking Capacity\u003c\/h2\u003e\n\u003cp\u003eThe RTA064030B has a rated short-circuit breaking capacity of \u003cstrong\u003e6000A \/ 6kA\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis enables the RCBO to provide short-circuit protection within installations where a 6kA protective device is appropriate. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eCompact Single Module Design\u003c\/h2\u003e\n\u003cp\u003eDespite combining residual current and overcurrent protection, the RTA064030B occupies only \u003cstrong\u003eone module\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIts compact dimensions of approximately \u003cstrong\u003e114 x 17.8 x 69.6mm\u003c\/strong\u003e make efficient use of available consumer unit space, particularly where multiple circuits require individual RCBO protection. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe device mounts onto a standard \u003cstrong\u003e35mm DIN rail\u003c\/strong\u003e and incorporates a \u003cstrong\u003e450mm flying neutral cable\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eIndividual Circuit Protection\u003c\/h2\u003e\n\u003cp\u003eUsing RCBOs allows individual outgoing circuits to receive their own residual current and overcurrent protection.\u003c\/p\u003e\n\u003cp\u003eThis arrangement can help minimise disruption when a fault occurs because the affected circuit has its own dedicated protective device rather than multiple circuits relying upon a shared RCD.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e FuseBox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Code:\u003c\/strong\u003e RTA064030B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e RCBO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 40A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Residual Operating Current:\u003c\/strong\u003e 30mA \/ 0.03A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCD Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResidual Current Characteristics:\u003c\/strong\u003e AC \u0026amp; Pulsating DC up to 6mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristic:\u003c\/strong\u003e B Curve, 3–5 In\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Breaking Capacity:\u003c\/strong\u003e 6000A \/ 6kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 230V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Rating:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Modules:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e 35mm DIN Rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Incoming Terminal Capacity:\u003c\/strong\u003e 1–16mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Outgoing Terminal Capacity:\u003c\/strong\u003e 1–10mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncoming Recommended Tightening Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutgoing Recommended Tightening Torque:\u003c\/strong\u003e 1.2Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlying Neutral Cable Length:\u003c\/strong\u003e 450mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Endurance:\u003c\/strong\u003e 10,000 Operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e PA6 \/ Nylon 6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.2kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBi-Directional:\u003c\/strong\u003e No\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eDomestic Electrical Installations\u003c\/li\u003e\n\u003cli\u003eAppropriate 40A Final Circuits\u003c\/li\u003e\n\u003cli\u003eResidential Properties\u003c\/li\u003e\n\u003cli\u003eNew-Build Electrical Installations\u003c\/li\u003e\n\u003cli\u003eConsumer Unit Replacements\u003c\/li\u003e\n\u003cli\u003eConsumer Unit Upgrades\u003c\/li\u003e\n\u003cli\u003eIndividual Circuit Protection\u003c\/li\u003e\n\u003cli\u003eAppropriate Heating Loads\u003c\/li\u003e\n\u003cli\u003eAppropriate Light Commercial Installations\u003c\/li\u003e\n\u003cli\u003eElectrical Distribution Upgrades\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose the FuseBox RTA064030B?\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTA064030B\u003c\/strong\u003e combines \u003cstrong\u003eoverload, short-circuit and 30mA residual current protection\u003c\/strong\u003e within one compact protective device.\u003c\/p\u003e\n\u003cp\u003eIts combination of a \u003cstrong\u003e40A rating, B Curve characteristic, Type A residual protection and 6kA breaking capacity\u003c\/strong\u003e makes it a practical solution for appropriately designed circuits within FuseBox consumer units.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003esingle-module DIN rail design\u003c\/strong\u003e also makes efficient use of available consumer unit space while providing dedicated RCBO protection to the connected circuit.\u003c\/p\u003e","brand":"FuseBox Consumer Units \u0026 Circuit Protection","offers":[{"title":"Default Title","offer_id":54694319980890,"sku":"RTA064030B","price":16.04,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/RTA_060630_B_fef9b50559_1c4e17f3-dfd9-46ef-ba4e-b0daa00fbf29.webp?v=1788437132","url":"https:\/\/account.alertelectrical.com\/products\/fusebox-40a-30ma-type-a-b-curve-6ka-rcbo-rta064030b","provider":"Alert Electrical","version":"1.0","type":"link"}