{"product_id":"fusebox-6a-30ma-type-a-b-curve-6ka-bi-directional-mini-rcbo-rtamb06bd","title":"FuseBox 6A 30mA Type A B Curve 6kA Bi-Directional Mini RCBO | RTAMB06BD","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eFuseBox 6A 30mA Type A B Curve 6kA Bi-Directional Mini RCBO | RTAMB06BD\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2\u003e6A Bi-Directional Type A Mini RCBO for FuseBox Consumer Units\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTAMB06BD\u003c\/strong\u003e is a compact \u003cstrong\u003e6A 30mA Type A bi-directional RCBO\u003c\/strong\u003e designed to provide combined overcurrent and residual current protection while allowing current to flow safely in either direction.\u003c\/p\u003e\n\u003cp\u003eFeaturing a \u003cstrong\u003eB Curve tripping characteristic, 6kA short-circuit capacity and 1P+N switched configuration\u003c\/strong\u003e, this mini RCBO protects against \u003cstrong\u003eoverloads, short circuits and earth leakage faults\u003c\/strong\u003e. Its bi-directional design makes it particularly suitable for modern electrical installations incorporating technologies such as \u003cstrong\u003esolar PV and other applications where current may flow in both directions\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eIts compact \u003cstrong\u003esingle-module format\u003c\/strong\u003e also helps maximise working space inside compatible FuseBox consumer units.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e6A Rated Current\u003c\/li\u003e\n\u003cli\u003e30mA Residual Operating Current\u003c\/li\u003e\n\u003cli\u003eType A Residual Current Protection\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBi-Directional Operation\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eB Curve Tripping Characteristic\u003c\/li\u003e\n\u003cli\u003e6kA Short-Circuit Breaking Capacity\u003c\/li\u003e\n\u003cli\u003eCombined RCD \u0026amp; MCB Protection\u003c\/li\u003e\n\u003cli\u003eProtects Against Overloads\u003c\/li\u003e\n\u003cli\u003eProtects Against Short Circuits\u003c\/li\u003e\n\u003cli\u003eProtects Against Earth Leakage Faults\u003c\/li\u003e\n\u003cli\u003eSuitable Where Current Can Flow in Either Direction\u003c\/li\u003e\n\u003cli\u003eIdeal for Appropriate Solar PV Applications\u003c\/li\u003e\n\u003cli\u003e1P + N Switched Configuration\u003c\/li\u003e\n\u003cli\u003eLine \u0026amp; Neutral Switched\u003c\/li\u003e\n\u003cli\u003eCompact Mini RCBO Design\u003c\/li\u003e\n\u003cli\u003eSingle Module Width\u003c\/li\u003e\n\u003cli\u003e230V AC\u003c\/li\u003e\n\u003cli\u003e50\/60Hz\u003c\/li\u003e\n\u003cli\u003eIP20\u003c\/li\u003e\n\u003cli\u003e35mm DIN Rail Mounting\u003c\/li\u003e\n\u003cli\u003eFlying Neutral Cable\u003c\/li\u003e\n\u003cli\u003eSuitable for FuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eIEC 61009-1 \u0026amp; IEC 61009-2-2 Compliant \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBi-Directional Protection for Modern Installations\u003c\/h2\u003e\n\u003cp\u003eOne of the key advantages of the \u003cstrong\u003eRTAMB06BD\u003c\/strong\u003e is its \u003cstrong\u003ebi-directional design\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eUnlike a protective device intended for only one direction of power flow, a bi-directional RCBO can accommodate current flowing in either direction. This makes it particularly relevant to modern installations incorporating \u003cstrong\u003esolar PV generation\u003c\/strong\u003e and other systems where power flow may not always be exclusively from the supply towards the load. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eCombined RCBO Circuit Protection\u003c\/h2\u003e\n\u003cp\u003eThe RTAMB06BD combines the functions of an \u003cstrong\u003eMCB and RCD within one compact device\u003c\/strong\u003e, providing protection against:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOverloads\u003c\/li\u003e\n\u003cli\u003eShort Circuits\u003c\/li\u003e\n\u003cli\u003eResidual Current \/ Earth Leakage Faults\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIndividual RCBO protection also helps improve circuit separation, allowing the affected circuit to have its own dedicated residual current and overcurrent protection.\u003c\/p\u003e\n\u003ch2\u003eType A 30mA Residual Current Protection\u003c\/h2\u003e\n\u003cp\u003eThe RTAMB06BD provides \u003cstrong\u003eType A residual current protection\u003c\/strong\u003e with a rated residual operating current of \u003cstrong\u003e30mA\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eType A devices are designed to respond to AC and pulsating DC residual currents, making them particularly relevant to modern electrical installations incorporating electronic equipment. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e6A B Curve Protection\u003c\/h2\u003e\n\u003cp\u003eThis model has a rated current of \u003cstrong\u003e6A\u003c\/strong\u003e and uses a \u003cstrong\u003eB Curve tripping characteristic\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe B Curve characteristic is specified at \u003cstrong\u003e3–5 In\u003c\/strong\u003e, with the 6A rating making the device suitable for appropriately designed lower-current circuits where this level of overcurrent protection is required. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eCorrect protective device selection should always consider the connected load, cable size, installation method and applicable wiring requirements.\u003c\/p\u003e\n\u003ch2\u003e6kA Short-Circuit Capacity\u003c\/h2\u003e\n\u003cp\u003eThe FuseBox RTAMB06BD has a rated short-circuit breaking capacity of \u003cstrong\u003e6000A \/ 6kA\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis enables the RCBO to provide short-circuit protection in installations where a 6kA rated protective device is appropriate. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e1P+N Switched Mini Design\u003c\/h2\u003e\n\u003cp\u003eThe RTAMB06BD features a \u003cstrong\u003e1P+N switched configuration\u003c\/strong\u003e, meaning both the line and neutral are switched.\u003c\/p\u003e\n\u003cp\u003eDespite providing combined RCBO protection and switched-neutral functionality, the device occupies just \u003cstrong\u003eone module\u003c\/strong\u003e, measuring approximately \u003cstrong\u003e18mm wide\u003c\/strong\u003e. Its compact construction helps increase available working space inside a FuseBox consumer unit. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e FuseBox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Code:\u003c\/strong\u003e RTAMB06BD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Bi-Directional Mini RCBO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 6A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Residual Operating Current:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCD Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperation:\u003c\/strong\u003e Bi-Directional\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristic:\u003c\/strong\u003e B Curve, 3–5 In\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Breaking Capacity:\u003c\/strong\u003e 6000A \/ 6kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 1P + N Switched\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 230V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Rating:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Modules:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e 35mm DIN Rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Incoming Terminal Capacity:\u003c\/strong\u003e 16mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Outgoing Terminal Capacity:\u003c\/strong\u003e 10mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncoming Recommended Tightening Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutgoing Recommended Tightening Torque:\u003c\/strong\u003e 1.2Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNeutral Cable CSA:\u003c\/strong\u003e 2.5mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Endurance:\u003c\/strong\u003e 10,000 Operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e PA6 \/ Nylon 6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e 85 x 18 x 69.5mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Approx. 0.144kg\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eDomestic Electrical Installations\u003c\/li\u003e\n\u003cli\u003eSolar PV Installations\u003c\/li\u003e\n\u003cli\u003eApplications with Bi-Directional Current Flow\u003c\/li\u003e\n\u003cli\u003eAppropriate Renewable Energy Installations\u003c\/li\u003e\n\u003cli\u003eResidential Properties\u003c\/li\u003e\n\u003cli\u003eNew-Build Electrical Installations\u003c\/li\u003e\n\u003cli\u003eConsumer Unit Upgrades\u003c\/li\u003e\n\u003cli\u003eAppropriate 6A Final Circuits\u003c\/li\u003e\n\u003cli\u003eIndividual Circuit Protection\u003c\/li\u003e\n\u003cli\u003eAppropriate Light Commercial Installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose the FuseBox RTAMB06BD?\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTAMB06BD\u003c\/strong\u003e combines compact dimensions with \u003cstrong\u003e6A overcurrent protection, 30mA Type A residual current protection and bi-directional operation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIts bi-directional capability makes it particularly useful for modern installations such as \u003cstrong\u003esolar PV systems\u003c\/strong\u003e, where current can flow in either direction. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWith a \u003cstrong\u003eB Curve characteristic, 6kA breaking capacity, switched line and neutral and single-module format\u003c\/strong\u003e, the RTAMB06BD provides a versatile circuit protection solution while making efficient use of available space within the consumer unit.\u003c\/p\u003e","brand":"FuseBox Consumer Units \u0026 Circuit Protection","offers":[{"title":"Default Title","offer_id":54694334005594,"sku":"RTAMB06BD","price":24.02,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/RTAMB_06_BD_ANGLE_7cb2d2b5c6.webp?v=1788437852","url":"https:\/\/account.alertelectrical.com\/products\/fusebox-6a-30ma-type-a-b-curve-6ka-bi-directional-mini-rcbo-rtamb06bd","provider":"Alert Electrical","version":"1.0","type":"link"}