{"product_id":"fusebox-6a-30ma-type-a-b-curve-6ka-rcbo-rta060630b","title":"FuseBox 6A 30mA Type A B Curve 6kA RCBO | RTA060630B","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eFuseBox 6A 30mA Type A B Curve 6kA RCBO | RTA060630B\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2\u003eSingle Module 6A Type A RCBO for FuseBox Consumer Units\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTA060630B\u003c\/strong\u003e is a \u003cstrong\u003e6A 30mA Type A RCBO\u003c\/strong\u003e designed to provide combined \u003cstrong\u003eovercurrent and residual current protection\u003c\/strong\u003e within FuseBox consumer units and compatible modular enclosures.\u003c\/p\u003e\n\u003cp\u003eCombining the functions of an \u003cstrong\u003eMCB and RCD in a single device\u003c\/strong\u003e, this RCBO protects against overloads, short circuits and earth leakage faults. Its \u003cstrong\u003eType A residual current characteristics\u003c\/strong\u003e allow detection of both AC and pulsating DC residual currents, making it suitable for modern electrical installations containing electronic equipment. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWith a \u003cstrong\u003eB Curve characteristic, 6kA short-circuit capacity and 30mA residual operating current\u003c\/strong\u003e, the RTA060630B provides reliable individual circuit protection while occupying just a single module within the consumer unit. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e6A Rated Current\u003c\/li\u003e\n\u003cli\u003e30mA Residual Operating Current\u003c\/li\u003e\n\u003cli\u003eType A Residual Current Protection\u003c\/li\u003e\n\u003cli\u003eB Curve Tripping Characteristic\u003c\/li\u003e\n\u003cli\u003e6kA Short-Circuit Breaking Capacity\u003c\/li\u003e\n\u003cli\u003eCombined Overload \u0026amp; Earth Leakage Protection\u003c\/li\u003e\n\u003cli\u003eProtects Against Short Circuits\u003c\/li\u003e\n\u003cli\u003eDetects AC \u0026amp; Pulsating DC Residual Currents\u003c\/li\u003e\n\u003cli\u003e1 Pole + Neutral Configuration\u003c\/li\u003e\n\u003cli\u003eSingle Module Design\u003c\/li\u003e\n\u003cli\u003e230V AC Rated Voltage\u003c\/li\u003e\n\u003cli\u003e50\/60Hz Frequency\u003c\/li\u003e\n\u003cli\u003eIP20 Rated\u003c\/li\u003e\n\u003cli\u003e35mm DIN Rail Mounting\u003c\/li\u003e\n\u003cli\u003eFlying Neutral Cable\u003c\/li\u003e\n\u003cli\u003eDesigned for FuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eComplies with IEC\/EN 61009-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCombined RCBO Circuit Protection\u003c\/h2\u003e\n\u003cp\u003eAn RCBO combines \u003cstrong\u003eresidual current protection and overcurrent protection\u003c\/strong\u003e within a single protective device.\u003c\/p\u003e\n\u003cp\u003eThe RTA060630B therefore provides protection against:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOverloads\u003c\/li\u003e\n\u003cli\u003eShort Circuits\u003c\/li\u003e\n\u003cli\u003eEarth Leakage \/ Residual Current Faults\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf an appropriate fault condition occurs, the RCBO disconnects the affected circuit, providing individual protection without relying on one shared RCD to protect several outgoing circuits. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eType A Residual Current Protection\u003c\/h2\u003e\n\u003cp\u003eThe RTA060630B is a \u003cstrong\u003eType A RCBO\u003c\/strong\u003e, designed to respond to \u003cstrong\u003eAC and pulsating DC residual currents\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eType A protection is particularly relevant to modern installations because many contemporary electrical and electronic appliances can produce residual currents with a pulsating DC component. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e6A B Curve Protection\u003c\/h2\u003e\n\u003cp\u003eRated at \u003cstrong\u003e6A\u003c\/strong\u003e, this model uses a \u003cstrong\u003eB Curve tripping characteristic\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIts rating makes it suitable for appropriately designed lower-current circuits, including applications such as lighting, subject to circuit design, cable selection and installation requirements. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e6kA Short-Circuit Capacity\u003c\/h2\u003e\n\u003cp\u003eThe RTA060630B has a rated \u003cstrong\u003e6kA short-circuit breaking capacity\u003c\/strong\u003e, providing protection against short-circuit fault currents within installations for which this rating is appropriate.\u003c\/p\u003e\n\u003cp\u003eFuseBox identifies the RTA series as its \u003cstrong\u003e6kA Type A RCBO range manufactured to BS\/IEC EN 61009-1\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSingle Module DIN Rail Design\u003c\/h2\u003e\n\u003cp\u003eThe RCBO uses a compact \u003cstrong\u003esingle-module format\u003c\/strong\u003e, helping maximise available space within the consumer unit.\u003c\/p\u003e\n\u003cp\u003eIt mounts onto a standard \u003cstrong\u003e35mm DIN rail\u003c\/strong\u003e and is specifically designed for use with FuseBox consumer units and modular enclosures. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e FuseBox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Code:\u003c\/strong\u003e RTA060630B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e RCBO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 6A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResidual Operating Current:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCD Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristic:\u003c\/strong\u003e B Curve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Short-Circuit Capacity:\u003c\/strong\u003e 6kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 230V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Rating:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Width:\u003c\/strong\u003e 1 Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e 35mm DIN Rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Incoming Terminal Capacity:\u003c\/strong\u003e 16mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Outgoing Terminal Capacity:\u003c\/strong\u003e 10mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e 114 x 17.8 x 69.6mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFuseBox Consumer Units\u003c\/li\u003e\n\u003cli\u003eDomestic Electrical Installations\u003c\/li\u003e\n\u003cli\u003eLighting Circuits\u003c\/li\u003e\n\u003cli\u003eResidential Properties\u003c\/li\u003e\n\u003cli\u003eNew-Build Installations\u003c\/li\u003e\n\u003cli\u003eConsumer Unit Upgrades\u003c\/li\u003e\n\u003cli\u003eCircuit Extensions\u003c\/li\u003e\n\u003cli\u003eIndividual Circuit Protection\u003c\/li\u003e\n\u003cli\u003eAppropriate Light Commercial Applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eElectrical circuit protection must always be selected according to the requirements of the circuit and applicable wiring regulations.\u003c\/p\u003e\n\u003ch2\u003eWhy Choose the FuseBox RTA060630B?\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFuseBox RTA060630B\u003c\/strong\u003e combines three important forms of circuit protection \u003cstrong\u003eoverload, short-circuit and residual current protection \u003c\/strong\u003ewithin one compact single-module device.\u003c\/p\u003e\n\u003cp\u003eIts \u003cstrong\u003e6A rating, B Curve characteristic, 30mA Type A residual protection and 6kA breaking capacity\u003c\/strong\u003e make it a practical choice for appropriately designed circuits within FuseBox consumer units.\u003c\/p\u003e\n\u003cp\u003eThe single-module DIN rail format also allows individual RCBO protection to be incorporated without unnecessarily consuming valuable space inside the consumer unit.\u003c\/p\u003e","brand":"FuseBox Consumer Units \u0026 Circuit Protection","offers":[{"title":"Default Title","offer_id":54694019793242,"sku":"RTA060630B","price":16.04,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/RTA_060630_B_fef9b50559.webp?v=1788434539","url":"https:\/\/account.alertelectrical.com\/products\/fusebox-6a-30ma-type-a-b-curve-6ka-rcbo-rta060630b","provider":"Alert Electrical","version":"1.0","type":"link"}