{"product_id":"hager-single-module-type-2-surge-protection-device-vmes02spd","title":"Hager Single Module Type 2 Surge Protection Device | VMES02SPD","description":"\u003ch1 class=\"MsoNormal\"\u003eHager Single Module Type 2 Surge Protection Device | VMES02SPD\u003c\/h1\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Hager VMES02SPD Single Module Type 2 Surge Protection Device is a compact, high-performance surge protection kit developed specifically for Hager consumer units, helping installers achieve compliance with the 18th Edition BS 7671.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis IEC Type 2 (Class II) SPD is designed for single-phase power supply networks and is suitable for CT2 connection in accordance with BS 7671:2018 Regulation 534.4.3.2. It offers reliable protection against transient overvoltages caused by lightning strikes and switching surges, helping to safeguard sensitive electrical equipment.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe VMES02SPD features an optical status indicator for easy visual inspection, with green indicating healthy operation and red signalling cartridge replacement required. The pluggable surge protection module allows the cartridge to be replaced quickly and safely without interrupting supply to connected loads, ensuring minimal downtime.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eCompatible with common UK earthing arrangements including TN-C-S (PME), TN-S, and TT systems, this SPD does not require secondary back-up protection, simplifying installation. Line connection is made via the consumer unit busbar, with neutral and earth connections provided via supplied 6mm cable links.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003eType 2 (Class II) Surge Protection Device – Suitable for 18th Edition compliance\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003eSingle Module Design – Compact and space-saving\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003eCT2 Connection Compatible – As per BS 7671 Regulation 534.4.3.2\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003eOptical Status Indicator – Green = healthy, Red = replace\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003ePluggable Cartridge – Easy replacement without interrupting supply\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003eNo Back-Up Protection Required – Simplifies installation\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003eCompatible with UK Earthing Systems – TN-C-S, TN-S, and TT\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003eDesigned for Hager Consumer Units – Optimised performance and fit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"MsoNormal\"\u003eTechnical Specification\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list 36.0pt;\"\u003eProduct Code: VMES02SPD\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list 36.0pt;\"\u003eProduct Type: Type 2 Surge Protection Device\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list 36.0pt;\"\u003eNumber of Modules: 1\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list 36.0pt;\"\u003eApplication: Hager consumer units\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list 36.0pt;\"\u003eSPD Classification: IEC Type 2 \/ Class II\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list 36.0pt;\"\u003eNetwork Type: TN-S, TT\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list 36.0pt;\"\u003eFrequency: 50–60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list 36.0pt;\"\u003eRated Operational Voltage (Ue): 230V\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list 36.0pt;\"\u003eContinuous Operating Voltage (Uc): 275V\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list 36.0pt;\"\u003eNominal Discharge Current (In): 20kA\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list 36.0pt;\"\u003eMaximum Discharge Current (Imax): 40kA\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list 36.0pt;\"\u003eVoltage Protection Level (Up): 1.5kV\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list 36.0pt;\"\u003eMaximum Overcurrent Protection (Fuse): 100A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l5 level1 lfo4; tab-stops: list 36.0pt;\"\u003eMounting: DIN rail (consumer unit)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l5 level1 lfo4; tab-stops: list 36.0pt;\"\u003eNominal Tightening Torque: 1.2–2.5 Nm\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l5 level1 lfo4; tab-stops: list 36.0pt;\"\u003eRemote Signalling Contact: No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003ePhysical\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l6 level1 lfo5; tab-stops: list 36.0pt;\"\u003eWidth: 17.5mm\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l6 level1 lfo5; tab-stops: list 36.0pt;\"\u003eHeight: 84mm\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l6 level1 lfo5; tab-stops: list 36.0pt;\"\u003eDepth: 74mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo6; tab-stops: list 36.0pt;\"\u003eOperating Temperature: -40°C to +60°C\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo6; tab-stops: list 36.0pt;\"\u003eStandards: IEC 61643-11 Type 2\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo6; tab-stops: list 36.0pt;\"\u003eREACH Compliant: Yes\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo6; tab-stops: list 36.0pt;\"\u003eRoHS Compliant: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003eReplacement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo7; tab-stops: list 36.0pt;\"\u003eReplacement Cartridge Reference: SPL013Z\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":53336065573210,"sku":"VMES02SPD","price":36.66,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/SPL213Z.webp?v=1768469665","url":"https:\/\/account.alertelectrical.com\/products\/hager-single-module-type-2-surge-protection-device-vmes02spd","provider":"Alert Electrical","version":"1.0","type":"link"}