{"product_id":"lewden-brcbo-b16-30-1hp-16a-b-curve-30ma-type-b-hp-heat-pump-rcbo-6ka","title":"Lewden BRCBO-B16\/30\/1HP 16A B Curve 30mA Type B-HP Heat Pump RCBO 6kA","description":"\u003ch1 data-section-id=\"vukqyg\" dir=\"auto\" data-start=\"0\" data-end=\"71\" class=\"PDq2pG_selectionAnchorContainer\"\u003eLewden BRCBO-B16\/30\/1HP 16A B Curve 30mA Type B-HP Heat Pump RCBO 6kA\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2 data-section-id=\"nrhnoa\" dir=\"auto\" data-start=\"73\" data-end=\"135\"\u003eEnhanced Type B RCBO Protection for Heat Pump Installations\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"137\" data-end=\"471\"\u003eThe \u003cstrong data-start=\"141\" data-end=\"168\"\u003eLewden BRCBO-B16\/30\/1HP\u003c\/strong\u003e is a specialist \u003cstrong data-start=\"185\" data-end=\"215\"\u003e16A B Curve Type B-HP RCBO\u003c\/strong\u003e designed for heat pump installations requiring enhanced residual-current protection. Combining \u003cstrong data-start=\"311\" data-end=\"377\"\u003e30mA RCD protection with overload and short-circuit protection\u003c\/strong\u003e in one compact device, it provides a space-saving solution for compatible heat pump circuits.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"473\" data-end=\"797\"\u003ePart of Lewden's specialist \u003cstrong data-start=\"501\" data-end=\"530\"\u003eB-HP Heat Pump RCBO range\u003c\/strong\u003e, this 16A model is designed to accommodate the higher-frequency residual currents that can occur with modern inverter-driven heat pump technology. Its compact \u003cstrong data-start=\"690\" data-end=\"719\"\u003e18mm single-module design\u003c\/strong\u003e also removes the need for the separate MCB required when using a Type B RCCB.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" dir=\"auto\" data-start=\"799\" data-end=\"814\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"816\" data-end=\"1527\"\u003e\n\u003cli data-section-id=\"13wikpe\" data-start=\"816\" data-end=\"844\"\u003eLewden B-HP Heat Pump RCBO\u003c\/li\u003e\n\u003cli data-section-id=\"cuw53m\" data-start=\"845\" data-end=\"876\"\u003eProduct code BRCBO-B16\/30\/1HP\u003c\/li\u003e\n\u003cli data-section-id=\"1nqvha9\" data-start=\"877\" data-end=\"896\"\u003e16A rated current\u003c\/li\u003e\n\u003cli data-section-id=\"qf5l3b\" data-start=\"897\" data-end=\"933\"\u003eB Curve overcurrent characteristic\u003c\/li\u003e\n\u003cli data-section-id=\"1oljaqy\" data-start=\"934\" data-end=\"991\"\u003eEnhanced Type B \/ Type B-HP residual-current protection\u003c\/li\u003e\n\u003cli data-section-id=\"m16dpx\" data-start=\"992\" data-end=\"1022\"\u003e30mA residual-current rating\u003c\/li\u003e\n\u003cli data-section-id=\"czhp9v\" data-start=\"1023\" data-end=\"1060\"\u003e6kA short-circuit breaking capacity\u003c\/li\u003e\n\u003cli data-section-id=\"1c44py2\" data-start=\"1061\" data-end=\"1106\"\u003ePurpose-designed for heat pump applications\u003c\/li\u003e\n\u003cli data-section-id=\"1vfay8r\" data-start=\"1107\" data-end=\"1156\"\u003eDesigned for higher-frequency residual currents\u003c\/li\u003e\n\u003cli data-section-id=\"1yg45up\" data-start=\"1157\" data-end=\"1204\"\u003eOperational at frequencies of 20kHz and above\u003c\/li\u003e\n\u003cli data-section-id=\"mtushs\" data-start=\"1205\" data-end=\"1246\"\u003eCombines RCD and overcurrent protection\u003c\/li\u003e\n\u003cli data-section-id=\"19zq6mr\" data-start=\"1247\" data-end=\"1273\"\u003eBi-directional operation\u003c\/li\u003e\n\u003cli data-section-id=\"l8d3aa\" data-start=\"1274\" data-end=\"1301\"\u003e1 pole + switched neutral\u003c\/li\u003e\n\u003cli data-section-id=\"1j40hqs\" data-start=\"1302\" data-end=\"1333\"\u003eCompact 1-module construction\u003c\/li\u003e\n\u003cli data-section-id=\"y1wpgq\" data-start=\"1334\" data-end=\"1350\"\u003eOnly 18mm wide\u003c\/li\u003e\n\u003cli data-section-id=\"frteb4\" data-start=\"1351\" data-end=\"1370\"\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli data-section-id=\"1ottkyv\" data-start=\"1371\" data-end=\"1419\"\u003eCompatible with suitable Lewden consumer units\u003c\/li\u003e\n\u003cli data-section-id=\"1239nik\" data-start=\"1420\" data-end=\"1452\"\u003eCertified to BS EN\/IEC 61009-1\u003c\/li\u003e\n\u003cli data-section-id=\"bkuz6n\" data-start=\"1453\" data-end=\"1483\"\u003eCertified to BS EN\/IEC 62423\u003c\/li\u003e\n\u003cli data-section-id=\"ulat75\" data-start=\"1484\" data-end=\"1527\"\u003eOperating temperature from -25°C to +40°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"r5lmxh\" dir=\"auto\" data-start=\"1529\" data-end=\"1576\"\u003eDesigned Specifically for Heat Pump Circuits\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"1578\" data-end=\"1804\"\u003eModern heat pumps frequently incorporate \u003cstrong data-start=\"1619\" data-end=\"1679\"\u003einverter technology and electronic power-control systems\u003c\/strong\u003e. These components can produce residual-current waveforms at frequencies considerably higher than the normal mains frequency.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1806\" data-end=\"2009\"\u003eMany heat pump manufacturers consequently specify \u003cstrong data-start=\"1856\" data-end=\"1904\"\u003eType F or Type B residual-current protection\u003c\/strong\u003e, while some require an enhanced Type B device capable of catering for higher-frequency leakage currents.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2011\" data-end=\"2224\"\u003eThe Lewden B-HP range has been developed specifically for these applications, providing a dedicated protective solution where the heat pump manufacturer's requirements call for its enhanced Type B characteristics.\u003c\/p\u003e\n\u003ch2 data-section-id=\"xv5df6\" dir=\"auto\" data-start=\"2226\" data-end=\"2275\"\u003eEnhanced Type B-HP Residual-Current Protection\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"2277\" data-end=\"2369\"\u003eThe BRCBO-B16\/30\/1HP provides Lewden's specialist \u003cstrong data-start=\"2327\" data-end=\"2368\"\u003eType B-HP residual-current protection\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2371\" data-end=\"2633\"\u003eSome heat pump manufacturers require an enhanced Type B RCD capable of catering for frequencies up to \u003cstrong data-start=\"2473\" data-end=\"2482\"\u003e20kHz\u003c\/strong\u003e, with a minimum trigger point of \u003cstrong data-start=\"2516\" data-end=\"2536\"\u003e150mA above 1kHz\u003c\/strong\u003e. Lewden specifies its B-HP RCBO technology as operational at frequencies of \u003cstrong data-start=\"2613\" data-end=\"2632\"\u003e20kHz and above\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2635\" data-end=\"2842\"\u003eThis enhanced high-frequency capability makes the device particularly relevant for heat pumps where conventional residual-current protection does not meet the equipment manufacturer's specified requirements.\u003c\/p\u003e\n\u003ch2 data-section-id=\"kkm8mq\" dir=\"auto\" data-start=\"2844\" data-end=\"2881\"\u003e16A B Curve Overcurrent Protection\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"2883\" data-end=\"3075\"\u003eThis variant has a \u003cstrong data-start=\"2902\" data-end=\"2923\"\u003e16A rated current\u003c\/strong\u003e with a \u003cstrong data-start=\"2931\" data-end=\"2969\"\u003eB Curve overcurrent characteristic\u003c\/strong\u003e, making it suitable for correctly designed heat pump circuits requiring these particular characteristics.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3077\" data-end=\"3276\"\u003eThe two \"B\" designations should not be confused. \u003cstrong data-start=\"3126\" data-end=\"3137\"\u003eB Curve\u003c\/strong\u003e describes the overcurrent tripping characteristic, whereas \u003cstrong data-start=\"3197\" data-end=\"3210\"\u003eType B-HP\u003c\/strong\u003e relates to the RCBO's residual-current detection characteristics.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3278\" data-end=\"3454\"\u003eThe protective device should always be selected according to the heat pump manufacturer's requirements, circuit design, cable characteristics and applicable wiring regulations.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1iqisos\" dir=\"auto\" data-start=\"3456\" data-end=\"3491\"\u003e30mA Residual-Current Protection\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"3493\" data-end=\"3656\"\u003eThe BRCBO-B16\/30\/1HP has a \u003cstrong data-start=\"3520\" data-end=\"3561\"\u003e30mA rated residual operating current\u003c\/strong\u003e, combining additional residual-current protection with Lewden's enhanced B-HP characteristics.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3658\" data-end=\"3814\"\u003eThis makes it a compact solution where both \u003cstrong data-start=\"3702\" data-end=\"3779\"\u003e16A overcurrent protection and 30mA Type B-HP residual-current protection\u003c\/strong\u003e are required from the same device.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1634e89\" dir=\"auto\" data-start=\"3816\" data-end=\"3861\"\u003eRCD \u0026amp; Overcurrent Protection in One Device\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"3863\" data-end=\"3905\"\u003eAs an RCBO, the BRCBO-B16\/30\/1HP combines:\u003c\/p\u003e\n\u003cul data-start=\"3907\" data-end=\"3985\"\u003e\n\u003cli data-section-id=\"7vl7b2\" data-start=\"3907\" data-end=\"3936\"\u003eResidual-current protection\u003c\/li\u003e\n\u003cli data-section-id=\"1sjnbqb\" data-start=\"3937\" data-end=\"3958\"\u003eOverload protection\u003c\/li\u003e\n\u003cli data-section-id=\"8idazr\" data-start=\"3959\" data-end=\"3985\"\u003eShort-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"3987\" data-end=\"4156\"\u003eThis offers a significant installation advantage over a Type B RCCB, which provides residual-current protection but requires appropriate separate overcurrent protection.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4158\" data-end=\"4301\"\u003eLewden's B-HP RCBO therefore eliminates the need for an additional MCB solely to provide the overcurrent protection required alongside an RCCB.\u003c\/p\u003e\n\u003ch2 data-section-id=\"bb2110\" dir=\"auto\" data-start=\"4303\" data-end=\"4339\"\u003eCompact 18mm Single-Module Design\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"4341\" data-end=\"4453\"\u003eOne of the key advantages of the Lewden B-HP range is its exceptionally compact \u003cstrong data-start=\"4421\" data-end=\"4452\"\u003e1-module, 18mm construction\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4455\" data-end=\"4662\"\u003eA Type B RCCB combined with an appropriate MCB can occupy approximately three consumer-unit modules. The BRCBO-B16\/30\/1HP provides residual-current and overcurrent protection within just \u003cstrong data-start=\"4642\" data-end=\"4661\"\u003eone 18mm module\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4664\" data-end=\"4776\"\u003eThis makes it particularly useful for heat pump installations where available consumer-unit capacity is limited.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1yfqy1q\" dir=\"auto\" data-start=\"4778\" data-end=\"4816\"\u003e6kA Short-Circuit Breaking Capacity\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"4818\" data-end=\"4946\"\u003eThe BRCBO-B16\/30\/1HP provides a \u003cstrong data-start=\"4850\" data-end=\"4889\"\u003e6kA short-circuit breaking capacity\u003c\/strong\u003e, alongside its overload and residual-current protection.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4948\" data-end=\"5133\"\u003eThe integrated design provides the principal RCBO protective functions within one device, reducing the number of individual protective devices required for a correctly designed circuit.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1wp1ljy\" dir=\"auto\" data-start=\"5135\" data-end=\"5162\"\u003eBi-Directional Operation\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"5164\" data-end=\"5301\"\u003eThe Lewden B-HP RCBO range features \u003cstrong data-start=\"5200\" data-end=\"5228\"\u003ebi-directional operation\u003c\/strong\u003e, providing greater flexibility within suitable electrical installations.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5303\" data-end=\"5469\"\u003eCombined with its enhanced Type B-HP characteristics, this makes the device well suited to modern electrical systems incorporating sophisticated electronic equipment.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1p6yvfz\" dir=\"auto\" data-start=\"5471\" data-end=\"5499\"\u003e1 Pole + Switched Neutral\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"5501\" data-end=\"5629\"\u003eThe BRCBO-B16\/30\/1HP uses a \u003cstrong data-start=\"5529\" data-end=\"5575\"\u003e1 pole plus switched neutral configuration\u003c\/strong\u003e while retaining its compact single-module dimensions.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5631\" data-end=\"5745\"\u003eThis provides switched-neutral functionality without requiring additional DIN rail space within the consumer unit.\u003c\/p\u003e\n\u003ch2 data-section-id=\"f743a3\" dir=\"auto\" data-start=\"5747\" data-end=\"5787\"\u003eCompatible with Lewden Consumer Units\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"5789\" data-end=\"5885\"\u003eLewden B-HP RCBOs are designed for installation within a \u003cstrong data-start=\"5846\" data-end=\"5884\"\u003estandard Lewden RCBO consumer unit\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5887\" data-end=\"5981\"\u003eThey can also be installed as one of the \u003cstrong data-start=\"5928\" data-end=\"5955\"\u003eHigh Integrity circuits\u003c\/strong\u003e within compatible Lewden:\u003c\/p\u003e\n\u003cul data-start=\"5983\" data-end=\"6066\"\u003e\n\u003cli data-section-id=\"1azb3cf\" data-start=\"5983\" data-end=\"6009\"\u003eDual RCCB consumer units\u003c\/li\u003e\n\u003cli data-section-id=\"19e6587\" data-start=\"6010\" data-end=\"6037\"\u003eSplit Load consumer units\u003c\/li\u003e\n\u003cli data-section-id=\"1svicmp\" data-start=\"6038\" data-end=\"6066\"\u003eDual Tariff consumer units\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"6068\" data-end=\"6235\"\u003eThis provides flexibility when installing a new dedicated heat pump circuit or incorporating heat pump protection into suitable existing Lewden distribution equipment.\u003c\/p\u003e\n\u003ch2 data-section-id=\"3nxlj6\" dir=\"auto\" data-start=\"6237\" data-end=\"6271\"\u003eCertified to Relevant Standards\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"6273\" data-end=\"6339\"\u003eThe Lewden B-HP Heat Pump RCBO range is specified as certified to:\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"6341\" data-end=\"6454\"\u003e\u003cstrong data-start=\"6341\" data-end=\"6362\"\u003eBS EN\/IEC 61009-1\u003c\/strong\u003e – covering residual-current operated circuit breakers with integral overcurrent protection.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"6456\" data-end=\"6588\"\u003e\u003cstrong data-start=\"6456\" data-end=\"6475\"\u003eBS EN\/IEC 62423\u003c\/strong\u003e – covering additional requirements associated with Type F and Type B residual-current operated circuit breakers.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"6590\" data-end=\"6654\"\u003eThe specified operating temperature range is \u003cstrong data-start=\"6635\" data-end=\"6653\"\u003e-25°C to +40°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1cgu054\" dir=\"auto\" data-start=\"6656\" data-end=\"6683\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"6685\" data-end=\"7553\"\u003e\n\u003cli data-section-id=\"1wxzd3s\" data-start=\"6685\" data-end=\"6704\"\u003e\n\u003cstrong data-start=\"6687\" data-end=\"6697\"\u003eBrand:\u003c\/strong\u003e Lewden\u003c\/li\u003e\n\u003cli data-section-id=\"1ulkgo6\" data-start=\"6705\" data-end=\"6737\"\u003e\n\u003cstrong data-start=\"6707\" data-end=\"6717\"\u003eRange:\u003c\/strong\u003e B-HP Heat Pump RCBO\u003c\/li\u003e\n\u003cli data-section-id=\"m0h5c8\" data-start=\"6738\" data-end=\"6774\"\u003e\n\u003cstrong data-start=\"6740\" data-end=\"6757\"\u003eProduct Code:\u003c\/strong\u003e BRCBO-B16\/30\/1HP\u003c\/li\u003e\n\u003cli data-section-id=\"ylcygt\" data-start=\"6775\" data-end=\"6809\"\u003e\n\u003cstrong data-start=\"6777\" data-end=\"6794\"\u003eProduct Type:\u003c\/strong\u003e Heat Pump RCBO\u003c\/li\u003e\n\u003cli data-section-id=\"1ye49ut\" data-start=\"6810\" data-end=\"6863\"\u003e\n\u003cstrong data-start=\"6812\" data-end=\"6835\"\u003eRCD Classification:\u003c\/strong\u003e Enhanced Type B \/ Type B-HP\u003c\/li\u003e\n\u003cli data-section-id=\"1oqdfvf\" data-start=\"6864\" data-end=\"6888\"\u003e\n\u003cstrong data-start=\"6866\" data-end=\"6884\"\u003eRated Current:\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli data-section-id=\"1pe8t0v\" data-start=\"6889\" data-end=\"6914\"\u003e\n\u003cstrong data-start=\"6891\" data-end=\"6906\"\u003eTrip Curve:\u003c\/strong\u003e B Curve\u003c\/li\u003e\n\u003cli data-section-id=\"1kgjev7\" data-start=\"6915\" data-end=\"6949\"\u003e\n\u003cstrong data-start=\"6917\" data-end=\"6944\"\u003eRated Residual Current:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n\u003cli data-section-id=\"2bbieh\" data-start=\"6950\" data-end=\"6992\"\u003e\n\u003cstrong data-start=\"6952\" data-end=\"6988\"\u003eShort-Circuit Breaking Capacity:\u003c\/strong\u003e 6kA\u003c\/li\u003e\n\u003cli data-section-id=\"2aw0n2\" data-start=\"6993\" data-end=\"7044\"\u003e\n\u003cstrong data-start=\"6995\" data-end=\"7018\"\u003ePole Configuration:\u003c\/strong\u003e 1 Pole + Switched Neutral\u003c\/li\u003e\n\u003cli data-section-id=\"13g7otv\" data-start=\"7045\" data-end=\"7070\"\u003e\n\u003cstrong data-start=\"7047\" data-end=\"7066\"\u003eBi-Directional:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli data-section-id=\"wetad\" data-start=\"7071\" data-end=\"7099\"\u003e\n\u003cstrong data-start=\"7073\" data-end=\"7090\"\u003eModule Width:\u003c\/strong\u003e 1 Module\u003c\/li\u003e\n\u003cli data-section-id=\"16gih25\" data-start=\"7100\" data-end=\"7117\"\u003e\n\u003cstrong data-start=\"7102\" data-end=\"7112\"\u003eWidth:\u003c\/strong\u003e 18mm\u003c\/li\u003e\n\u003cli data-section-id=\"w5r5l7\" data-start=\"7118\" data-end=\"7156\"\u003e\n\u003cstrong data-start=\"7120\" data-end=\"7152\"\u003eResidual-Current Protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli data-section-id=\"kksbti\" data-start=\"7157\" data-end=\"7187\"\u003e\n\u003cstrong data-start=\"7159\" data-end=\"7183\"\u003eOverload Protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli data-section-id=\"g5bqk2\" data-start=\"7188\" data-end=\"7223\"\u003e\n\u003cstrong data-start=\"7190\" data-end=\"7219\"\u003eShort-Circuit Protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli data-section-id=\"wiogj3\" data-start=\"7224\" data-end=\"7271\"\u003e\n\u003cstrong data-start=\"7226\" data-end=\"7255\"\u003eHigh-Frequency Operation:\u003c\/strong\u003e 20kHz and Above\u003c\/li\u003e\n\u003cli data-section-id=\"1wo3hbe\" data-start=\"7272\" data-end=\"7296\"\u003e\n\u003cstrong data-start=\"7274\" data-end=\"7287\"\u003eMounting:\u003c\/strong\u003e DIN Rail\u003c\/li\u003e\n\u003cli data-section-id=\"1dzipgd\" data-start=\"7297\" data-end=\"7340\"\u003e\n\u003cstrong data-start=\"7299\" data-end=\"7325\"\u003eOperating Temperature:\u003c\/strong\u003e -25°C to +40°C\u003c\/li\u003e\n\u003cli data-section-id=\"g1g44v\" data-start=\"7341\" data-end=\"7393\"\u003e\n\u003cstrong data-start=\"7343\" data-end=\"7357\"\u003eStandards:\u003c\/strong\u003e BS EN\/IEC 61009-1 \u0026amp; BS EN\/IEC 62423\u003c\/li\u003e\n\u003cli data-section-id=\"r9uqs4\" data-start=\"7394\" data-end=\"7449\"\u003e\n\u003cstrong data-start=\"7396\" data-end=\"7420\"\u003ePrimary Application:\u003c\/strong\u003e Heat Pump Circuit Protection\u003c\/li\u003e\n\u003cli data-section-id=\"143eaiu\" data-start=\"7450\" data-end=\"7553\"\u003e\n\u003cstrong data-start=\"7452\" data-end=\"7484\"\u003eConsumer Unit Compatibility:\u003c\/strong\u003e Suitable Lewden RCBO Consumer Units \u0026amp; Compatible High Integrity Ways\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"11cc03h\" dir=\"auto\" data-start=\"7555\" data-end=\"7579\"\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul data-start=\"7581\" data-end=\"8009\"\u003e\n\u003cli data-section-id=\"fqu7i4\" data-start=\"7581\" data-end=\"7604\"\u003eAir Source Heat Pumps\u003c\/li\u003e\n\u003cli data-section-id=\"imj7c3\" data-start=\"7605\" data-end=\"7631\"\u003eGround Source Heat Pumps\u003c\/li\u003e\n\u003cli data-section-id=\"74meq9\" data-start=\"7632\" data-end=\"7660\"\u003eInverter-Driven Heat Pumps\u003c\/li\u003e\n\u003cli data-section-id=\"1spauvk\" data-start=\"7661\" data-end=\"7689\"\u003eDomestic Heat Pump Systems\u003c\/li\u003e\n\u003cli data-section-id=\"s3yts2\" data-start=\"7690\" data-end=\"7720\"\u003eCommercial Heat Pump Systems\u003c\/li\u003e\n\u003cli data-section-id=\"qwel2t\" data-start=\"7721\" data-end=\"7755\"\u003eDedicated 16A Heat Pump Circuits\u003c\/li\u003e\n\u003cli data-section-id=\"1xpve3w\" data-start=\"7756\" data-end=\"7784\"\u003eLow-Carbon Heating Systems\u003c\/li\u003e\n\u003cli data-section-id=\"18wn2\" data-start=\"7785\" data-end=\"7818\"\u003eRenewable Heating Installations\u003c\/li\u003e\n\u003cli data-section-id=\"8s2crf\" data-start=\"7819\" data-end=\"7857\"\u003eResidential Electrical Installations\u003c\/li\u003e\n\u003cli data-section-id=\"1aq811x\" data-start=\"7858\" data-end=\"7895\"\u003eCommercial Electrical Installations\u003c\/li\u003e\n\u003cli data-section-id=\"1kpmab6\" data-start=\"7896\" data-end=\"7919\"\u003eLewden Consumer Units\u003c\/li\u003e\n\u003cli data-section-id=\"uawvsp\" data-start=\"7920\" data-end=\"7959\"\u003eHigh Integrity Consumer Unit Circuits\u003c\/li\u003e\n\u003cli data-section-id=\"62a6p0\" data-start=\"7960\" data-end=\"8009\"\u003eHeat Pumps Requiring Enhanced Type B Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1okxjg5\" dir=\"auto\" data-start=\"8011\" data-end=\"8053\"\u003eWhy Choose the Lewden BRCBO-B16\/30\/1HP?\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"8055\" data-end=\"8213\"\u003eThe \u003cstrong data-start=\"8059\" data-end=\"8086\"\u003eLewden BRCBO-B16\/30\/1HP\u003c\/strong\u003e provides a specialist protective solution for heat pump circuits requiring an enhanced Type B residual-current characteristic.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"8215\" data-end=\"8519\"\u003eIt combines \u003cstrong data-start=\"8227\" data-end=\"8341\"\u003e16A B Curve overcurrent protection, 30mA residual-current protection and a 6kA short-circuit breaking capacity\u003c\/strong\u003e in a single RCBO. The specialist \u003cstrong data-start=\"8375\" data-end=\"8403\"\u003eType B-HP characteristic\u003c\/strong\u003e is designed to accommodate the higher-frequency residual currents associated with certain modern heat pump systems.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"8521\" data-end=\"8761\"\u003eIts \u003cstrong data-start=\"8525\" data-end=\"8554\"\u003e18mm single-module design\u003c\/strong\u003e is also a major practical advantage. Rather than using a Type B RCCB together with a separate MCB, installers can provide both residual-current and overcurrent protection from one compact protective device.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"8763\" data-end=\"9081\"\u003eWith \u003cstrong data-start=\"8768\" data-end=\"8894\"\u003ebi-directional operation, 1 pole plus switched neutral configuration and compatibility with suitable Lewden consumer units\u003c\/strong\u003e, the BRCBO-B16\/30\/1HP provides a neat and space-efficient solution where its particular B-HP protection characteristics are specified by the heat pump manufacturer and electrical design.\u003c\/p\u003e","brand":"Lewden","offers":[{"title":"Default Title","offer_id":54919710048602,"sku":"BRCBO-B16\/30\/1HP","price":148.79,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/BRCBO-B16-30-1HP_CAL.png?v=1791375754","url":"https:\/\/account.alertelectrical.com\/products\/lewden-brcbo-b16-30-1hp-16a-b-curve-30ma-type-b-hp-heat-pump-rcbo-6ka","provider":"Alert Electrical","version":"1.0","type":"link"}