{"product_id":"lewden-hppi-r06w-a-pro-6-way-heat-pump-ip20-consumer-unit-with-b6-b20-rcbos-and-type-2-spd","title":"Lewden HPPI-R06W-A PRO 6 Way Heat Pump IP20 Consumer Unit with B6 \u0026 B20 RCBOs and Type 2 SPD","description":"\u003ch1 data-section-id=\"1d8dxm0\" dir=\"auto\" data-start=\"0\" data-end=\"99\" class=\"PDq2pG_selectionAnchorContainer\"\u003eLewden HPPI-R06W-A PRO 6 Way Heat Pump IP20 Consumer Unit with B6 \u0026amp; B20 RCBOs and Type 2 SPD\u003c\/h1\u003e\n\u003ch2 data-section-id=\"1jo0gcs\" dir=\"auto\" data-start=\"91\" data-end=\"162\" class=\"PDq2pG_selectionAnchorContainer\"\u003eDedicated 6 Way Consumer Unit for Air Source Heat Pump Installations\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"164\" data-end=\"568\"\u003eThe \u003cstrong data-start=\"168\" data-end=\"190\"\u003eLewden HPPI-R06W-A\u003c\/strong\u003e is a purpose-configured \u003cstrong data-start=\"215\" data-end=\"249\"\u003ePRO Series 6 way consumer unit\u003c\/strong\u003e designed for modern \u003cstrong data-start=\"270\" data-end=\"315\"\u003eair source heat pump (ASHP) installations\u003c\/strong\u003e. Supplied with a \u003cstrong data-start=\"333\" data-end=\"417\"\u003e100A main switch, B6 and B20 Type A RCBOs and integrated Type 2 surge protection\u003c\/strong\u003e, it provides a compact, installer-friendly distribution solution for heat pump controls, immersion heater circuits and additional associated circuits.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"570\" data-end=\"870\"\u003eThe unit is designed with inverter-driven heat pump systems in mind and provides \u003cstrong data-start=\"651\" data-end=\"668\"\u003e6 usable ways\u003c\/strong\u003e within a compact \u003cstrong data-start=\"686\" data-end=\"708\"\u003e9-module enclosure\u003c\/strong\u003e. Spare ways allow additional heat pump circuits, such as integral heaters, to be added where required by the system design. \u003cspan class=\"contents\" data-content-reference-start=\"833\" data-content-reference-end=\"852\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" dir=\"auto\" data-start=\"872\" data-end=\"887\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"889\" data-end=\"1559\"\u003e\n\u003cli data-section-id=\"u6tkbb\" data-start=\"889\" data-end=\"932\"\u003eLewden PRO Series heat pump consumer unit\u003c\/li\u003e\n\u003cli data-section-id=\"1nn26ml\" data-start=\"933\" data-end=\"959\"\u003eProduct code HPPI-R06W-A\u003c\/li\u003e\n\u003cli data-section-id=\"1qjm99k\" data-start=\"960\" data-end=\"1009\"\u003eDesigned for air source heat pump installations\u003c\/li\u003e\n\u003cli data-section-id=\"121ljgu\" data-start=\"1010\" data-end=\"1025\"\u003e6 usable ways\u003c\/li\u003e\n\u003cli data-section-id=\"11x44v0\" data-start=\"1026\" data-end=\"1046\"\u003e9-module enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"kj9h80\" data-start=\"1047\" data-end=\"1073\"\u003e100A main switch incomer\u003c\/li\u003e\n\u003cli data-section-id=\"yza7ij\" data-start=\"1074\" data-end=\"1109\"\u003ePre-fitted 6A B Curve Type A RCBO\u003c\/li\u003e\n\u003cli data-section-id=\"tm0gan\" data-start=\"1110\" data-end=\"1146\"\u003ePre-fitted 20A B Curve Type A RCBO\u003c\/li\u003e\n\u003cli data-section-id=\"1to4a53\" data-start=\"1147\" data-end=\"1188\"\u003eType 2 Surge Protection Device included\u003c\/li\u003e\n\u003cli data-section-id=\"1u6sjso\" data-start=\"1189\" data-end=\"1225\"\u003eB6 RCBO intended for ASHP controls\u003c\/li\u003e\n\u003cli data-section-id=\"1u35jfr\" data-start=\"1226\" data-end=\"1280\"\u003eB20 RCBO intended for immersion heater final circuit\u003c\/li\u003e\n\u003cli data-section-id=\"a3xryb\" data-start=\"1281\" data-end=\"1327\"\u003eSpare ways for additional heat pump circuits\u003c\/li\u003e\n\u003cli data-section-id=\"1qlp06b\" data-start=\"1328\" data-end=\"1358\"\u003eCompact PRO Series enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"1nvdyrt\" data-start=\"1359\" data-end=\"1371\"\u003e230V rated\u003c\/li\u003e\n\u003cli data-section-id=\"1xw5t75\" data-start=\"1372\" data-end=\"1389\"\u003eTop-hinged door\u003c\/li\u003e\n\u003cli data-section-id=\"hepged\" data-start=\"1390\" data-end=\"1419\"\u003eRound cable-entry knockouts\u003c\/li\u003e\n\u003cli data-section-id=\"76lip5\" data-start=\"1420\" data-end=\"1469\"\u003eSuitable for cable glands, conduit and grommets\u003c\/li\u003e\n\u003cli data-section-id=\"1m7nogq\" data-start=\"1470\" data-end=\"1506\"\u003eSuitable for SWA cable termination\u003c\/li\u003e\n\u003cli data-section-id=\"1isoxn4\" data-start=\"1507\" data-end=\"1559\"\u003eCompact design for space-constrained installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"zmqdi5\" dir=\"auto\" data-start=\"1561\" data-end=\"1601\"\u003ePre-Configured for ASHP Installations\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"1603\" data-end=\"1736\"\u003eThe HPPI-R06W-A has been configured specifically around the requirements of modern \u003cstrong data-start=\"1686\" data-end=\"1735\"\u003eair source heat pump electrical installations\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1738\" data-end=\"2030\"\u003eRather than starting with an empty consumer unit and selecting each component separately, this Lewden PRO unit includes the principal devices required for its intended configuration: a \u003cstrong data-start=\"1923\" data-end=\"1991\"\u003e100A main switch, 6A and 20A B Curve Type A RCBOs and Type 2 SPD\u003c\/strong\u003e. \u003cspan class=\"contents\" data-content-reference-start=\"1975\" data-content-reference-end=\"1994\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2032\" data-end=\"2155\"\u003eThis provides installers with a neat dedicated distribution point for the heat pump and its associated electrical circuits.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1a77h0x\" dir=\"auto\" data-start=\"2157\" data-end=\"2192\"\u003eB6 Type A RCBO for ASHP Controls\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"2194\" data-end=\"2269\"\u003eA \u003cstrong data-start=\"2196\" data-end=\"2222\"\u003e6A B Curve Type A RCBO\u003c\/strong\u003e is supplied for the heat pump control circuit.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2271\" data-end=\"2501\"\u003eAs an RCBO, it combines residual-current protection with overload and short-circuit protection for the individual final circuit, helping provide more targeted protection than arrangements where several circuits share a single RCD.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1a4fbmq\" dir=\"auto\" data-start=\"2503\" data-end=\"2550\"\u003eB20 Type A RCBO for Immersion Heater Circuit\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"2552\" data-end=\"2709\"\u003eThe second supplied device is a \u003cstrong data-start=\"2584\" data-end=\"2611\"\u003e20A B Curve Type A RCBO\u003c\/strong\u003e, intended for an associated immersion heater final circuit. \u003cspan class=\"contents\" data-content-reference-start=\"2636\" data-content-reference-end=\"2655\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2711\" data-end=\"2895\"\u003eHaving separate RCBO protection for the controls and immersion heater helps create a well-organised dedicated heat pump installation while retaining spare ways for additional circuits.\u003c\/p\u003e\n\u003ch2 data-section-id=\"3imtot\" dir=\"auto\" data-start=\"2897\" data-end=\"2934\"\u003eIntegrated Type 2 Surge Protection\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"2936\" data-end=\"3015\"\u003eThe Lewden HPPI-R06W-A incorporates a \u003cstrong data-start=\"2974\" data-end=\"3014\"\u003eType 2 Surge Protection Device (SPD)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3017\" data-end=\"3267\"\u003eThe SPD helps protect the installation and connected equipment against transient overvoltages. This is particularly useful with modern heat pump systems incorporating electronic controls, inverter technology and other sensitive electronic components.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3269\" data-end=\"3384\"\u003eIntegrating the SPD into the consumer unit also avoids the need for a separate external surge-protection enclosure.\u003c\/p\u003e\n\u003ch2 data-section-id=\"r8559o\" dir=\"auto\" data-start=\"3386\" data-end=\"3405\"\u003e100A Main Switch\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"3407\" data-end=\"3535\"\u003eThe incoming device is a \u003cstrong data-start=\"3432\" data-end=\"3463\"\u003e100A main switch \/ isolator\u003c\/strong\u003e, providing a convenient means of isolating the dedicated consumer unit.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3537\" data-end=\"3676\"\u003eLewden's configuration uses \u003cstrong data-start=\"3565\" data-end=\"3589\"\u003edual screw terminals\u003c\/strong\u003e to provide secure termination of incoming tails. \u003cspan class=\"contents\" data-content-reference-start=\"3585\" data-content-reference-end=\"3604\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3678\" data-end=\"3988\"\u003eUnlike the related HPPI-R04W-1 configuration, the \u003cstrong data-start=\"3728\" data-end=\"3774\"\u003eHPPI-R06W-A does not include a Type B RCCB\u003c\/strong\u003e. Its supplied circuit protection consists of the B6 and B20 Type A RCBOs, together with the 100A main switch and Type 2 SPD. This distinction is important when selecting the correct Lewden heat pump consumer unit.\u003c\/p\u003e\n\u003ch2 data-section-id=\"12rn0g3\" dir=\"auto\" data-start=\"3990\" data-end=\"4032\"\u003eSix Usable Ways for Greater Flexibility\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"4034\" data-end=\"4162\"\u003eThe HPPI-R06W-A provides \u003cstrong data-start=\"4059\" data-end=\"4076\"\u003e6 usable ways\u003c\/strong\u003e, offering greater expansion capacity than smaller dedicated heat pump consumer units.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4164\" data-end=\"4379\"\u003eThe supplied B6 and B20 RCBOs provide protection for the intended control and immersion heater circuits, while the remaining capacity can accommodate additional circuits where required by the heat pump installation.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4381\" data-end=\"4506\"\u003eLewden identifies \u003cstrong data-start=\"4399\" data-end=\"4427\"\u003eintegral heater circuits\u003c\/strong\u003e as one potential use for the spare ways. \u003cspan class=\"contents\" data-content-reference-start=\"4397\" data-content-reference-end=\"4416\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4508\" data-end=\"4642\"\u003eAny additional protective devices should be selected according to the heat pump manufacturer's instructions and the electrical design.\u003c\/p\u003e\n\u003ch2 data-section-id=\"cdbxq8\" dir=\"auto\" data-start=\"4644\" data-end=\"4684\"\u003eCompact 9-Module PRO Series Enclosure\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"4686\" data-end=\"4900\"\u003eDespite offering six usable ways, the HPPI-R06W-A is housed within a compact \u003cstrong data-start=\"4763\" data-end=\"4796\"\u003e9-module PRO Series enclosure\u003c\/strong\u003e measuring approximately \u003cstrong data-start=\"4821\" data-end=\"4861\"\u003e268mm high x 208mm wide x 109mm deep\u003c\/strong\u003e. \u003cspan class=\"contents\" data-content-reference-start=\"4773\" data-content-reference-end=\"4792\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4902\" data-end=\"5030\"\u003eThis makes the unit particularly useful where a dedicated heat pump consumer unit is required but installation space is limited.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1u0fy84\" dir=\"auto\" data-start=\"5032\" data-end=\"5065\"\u003eInstaller-Friendly Cable Entry\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"5067\" data-end=\"5186\"\u003eLewden equips the enclosure with \u003cstrong data-start=\"5100\" data-end=\"5119\"\u003eround knockouts\u003c\/strong\u003e, giving installers practical options for different wiring methods.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5188\" data-end=\"5222\"\u003eThe cable entries can accommodate:\u003c\/p\u003e\n\u003cul data-start=\"5224\" data-end=\"5289\"\u003e\n\u003cli data-section-id=\"14jo5ea\" data-start=\"5224\" data-end=\"5238\"\u003eCable glands\u003c\/li\u003e\n\u003cli data-section-id=\"60eoh2\" data-start=\"5239\" data-end=\"5248\"\u003eConduit\u003c\/li\u003e\n\u003cli data-section-id=\"yyq8zd\" data-start=\"5249\" data-end=\"5265\"\u003eCable grommets\u003c\/li\u003e\n\u003cli data-section-id=\"1lump1s\" data-start=\"5266\" data-end=\"5289\"\u003eSWA cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"5291\" data-end=\"5446\"\u003eThis helps make the consumer unit adaptable to different heat pump installation layouts and cable-entry requirements. \u003cspan class=\"contents\" data-content-reference-start=\"5301\" data-content-reference-end=\"5320\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1w0p0w4\" dir=\"auto\" data-start=\"5448\" data-end=\"5490\"\u003eDesigned for Modern Inverter Heat Pumps\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"5492\" data-end=\"5686\"\u003eLewden describes the HPPI-R06W-A as intended for \u003cstrong data-start=\"5541\" data-end=\"5596\"\u003eASHP installations with inverter-driven compressors\u003c\/strong\u003e, including equipment operating at high frequencies. \u003cspan class=\"contents\" data-content-reference-start=\"5523\" data-content-reference-end=\"5542\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5688\" data-end=\"5886\"\u003eHowever, the exact RCD and circuit-protection requirements of the connected heat pump should always be checked against the \u003cstrong data-start=\"5811\" data-end=\"5885\"\u003eheat pump manufacturer's instructions and the electrical system design\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5888\" data-end=\"6101\"\u003eWhere a heat pump specifically requires Lewden's enhanced \u003cstrong data-start=\"5946\" data-end=\"5975\"\u003eType B-HP RCBO protection\u003c\/strong\u003e, an appropriate B-HP protective device or a pre-configured Lewden consumer unit incorporating one should be selected instead.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1cgu054\" dir=\"auto\" data-start=\"6103\" data-end=\"6130\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"6132\" data-end=\"6783\"\u003e\n\u003cli data-section-id=\"1wxzd3s\" data-start=\"6132\" data-end=\"6151\"\u003e\n\u003cstrong data-start=\"6134\" data-end=\"6144\"\u003eBrand:\u003c\/strong\u003e Lewden\u003c\/li\u003e\n\u003cli data-section-id=\"16oaq8r\" data-start=\"6152\" data-end=\"6175\"\u003e\n\u003cstrong data-start=\"6154\" data-end=\"6164\"\u003eRange:\u003c\/strong\u003e PRO Series\u003c\/li\u003e\n\u003cli data-section-id=\"mwp3h3\" data-start=\"6176\" data-end=\"6207\"\u003e\n\u003cstrong data-start=\"6178\" data-end=\"6195\"\u003eProduct Code:\u003c\/strong\u003e HPPI-R06W-A\u003c\/li\u003e\n\u003cli data-section-id=\"v3k6s9\" data-start=\"6208\" data-end=\"6251\"\u003e\n\u003cstrong data-start=\"6210\" data-end=\"6227\"\u003eProduct Type:\u003c\/strong\u003e Heat Pump Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"6w8qmk\" data-start=\"6252\" data-end=\"6313\"\u003e\n\u003cstrong data-start=\"6254\" data-end=\"6278\"\u003ePrimary Application:\u003c\/strong\u003e Air Source Heat Pump Installations\u003c\/li\u003e\n\u003cli data-section-id=\"1b30mvy\" data-start=\"6314\" data-end=\"6344\"\u003e\n\u003cstrong data-start=\"6316\" data-end=\"6342\"\u003eNumber of Usable Ways:\u003c\/strong\u003e 6\u003c\/li\u003e\n\u003cli data-section-id=\"1cpabu0\" data-start=\"6345\" data-end=\"6371\"\u003e\n\u003cstrong data-start=\"6347\" data-end=\"6369\"\u003eNumber of Modules:\u003c\/strong\u003e 9\u003c\/li\u003e\n\u003cli data-section-id=\"1gwjw9n\" data-start=\"6372\" data-end=\"6422\"\u003e\n\u003cstrong data-start=\"6374\" data-end=\"6394\"\u003eIncoming Device:\u003c\/strong\u003e 100A Main Switch \/ Isolator\u003c\/li\u003e\n\u003cli data-section-id=\"najecs\" data-start=\"6423\" data-end=\"6449\"\u003e\n\u003cstrong data-start=\"6425\" data-end=\"6444\"\u003eCurrent Rating:\u003c\/strong\u003e 100A\u003c\/li\u003e\n\u003cli data-section-id=\"o34f0g\" data-start=\"6450\" data-end=\"6495\"\u003e\n\u003cstrong data-start=\"6452\" data-end=\"6472\"\u003eIncluded RCBO 1:\u003c\/strong\u003e 6A B Curve Type A RCBO\u003c\/li\u003e\n\u003cli data-section-id=\"v7u8c7\" data-start=\"6496\" data-end=\"6542\"\u003e\n\u003cstrong data-start=\"6498\" data-end=\"6518\"\u003eIncluded RCBO 2:\u003c\/strong\u003e 20A B Curve Type A RCBO\u003c\/li\u003e\n\u003cli data-section-id=\"151lfrc\" data-start=\"6543\" data-end=\"6570\"\u003e\n\u003cstrong data-start=\"6545\" data-end=\"6566\"\u003eSurge Protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli data-section-id=\"1oxpy3r\" data-start=\"6571\" data-end=\"6593\"\u003e\n\u003cstrong data-start=\"6573\" data-end=\"6586\"\u003eSPD Type:\u003c\/strong\u003e Type 2\u003c\/li\u003e\n\u003cli data-section-id=\"h6nwy8\" data-start=\"6594\" data-end=\"6620\"\u003e\n\u003cstrong data-start=\"6596\" data-end=\"6615\"\u003eVoltage Rating:\u003c\/strong\u003e 230V\u003c\/li\u003e\n\u003cli data-section-id=\"1el1dge\" data-start=\"6621\" data-end=\"6648\"\u003e\n\u003cstrong data-start=\"6623\" data-end=\"6637\"\u003eDoor Type:\u003c\/strong\u003e Top Hinged\u003c\/li\u003e\n\u003cli data-section-id=\"cpcz9\" data-start=\"6649\" data-end=\"6700\"\u003e\n\u003cstrong data-start=\"6651\" data-end=\"6666\"\u003eDimensions:\u003c\/strong\u003e 268mm (H) x 208mm (W) x 109mm (D)\u003c\/li\u003e\n\u003cli data-section-id=\"oho93m\" data-start=\"6701\" data-end=\"6735\"\u003e\n\u003cstrong data-start=\"6703\" data-end=\"6719\"\u003eCable Entry:\u003c\/strong\u003e Round Knockouts\u003c\/li\u003e\n\u003cli data-section-id=\"tn64kq\" data-start=\"6736\" data-end=\"6759\"\u003e\n\u003cstrong data-start=\"6738\" data-end=\"6751\"\u003eMounting:\u003c\/strong\u003e Surface\u003c\/li\u003e\n\u003cli data-section-id=\"50imk6\" data-start=\"6760\" data-end=\"6783\"\u003e\n\u003cstrong data-start=\"6762\" data-end=\"6776\"\u003eGuarantee:\u003c\/strong\u003e 1 Year\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"6785\" data-end=\"6929\"\u003eThe core configuration and dimensions are confirmed by a current UK listing for the exact \u003cstrong data-start=\"6875\" data-end=\"6890\"\u003eHPPI-R06W-A\u003c\/strong\u003e. \u003cspan class=\"contents\" data-content-reference-start=\"6748\" data-content-reference-end=\"6767\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"11cc03h\" dir=\"auto\" data-start=\"6931\" data-end=\"6955\"\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul data-start=\"6957\" data-end=\"7339\"\u003e\n\u003cli data-section-id=\"1bc001s\" data-start=\"6957\" data-end=\"6993\"\u003eAir Source Heat Pump Installations\u003c\/li\u003e\n\u003cli data-section-id=\"v5w0bd\" data-start=\"6994\" data-end=\"7020\"\u003eASHP Electrical Supplies\u003c\/li\u003e\n\u003cli data-section-id=\"1loldjo\" data-start=\"7021\" data-end=\"7056\"\u003eInverter-Driven Heat Pump Systems\u003c\/li\u003e\n\u003cli data-section-id=\"z5dl1r\" data-start=\"7057\" data-end=\"7085\"\u003eHeat Pump Control Circuits\u003c\/li\u003e\n\u003cli data-section-id=\"s4lcsi\" data-start=\"7086\" data-end=\"7113\"\u003eImmersion Heater Circuits\u003c\/li\u003e\n\u003cli data-section-id=\"sdh37t\" data-start=\"7114\" data-end=\"7150\"\u003eIntegral Heat Pump Heater Circuits\u003c\/li\u003e\n\u003cli data-section-id=\"1t0x32h\" data-start=\"7151\" data-end=\"7185\"\u003eDomestic Heat Pump Installations\u003c\/li\u003e\n\u003cli data-section-id=\"1tbd014\" data-start=\"7186\" data-end=\"7218\"\u003eResidential Low-Carbon Heating\u003c\/li\u003e\n\u003cli data-section-id=\"18xptev\" data-start=\"7219\" data-end=\"7246\"\u003eRenewable Heating Systems\u003c\/li\u003e\n\u003cli data-section-id=\"1svo5e1\" data-start=\"7247\" data-end=\"7281\"\u003eDedicated Heat Pump Distribution\u003c\/li\u003e\n\u003cli data-section-id=\"9k3cyp\" data-start=\"7282\" data-end=\"7339\"\u003eHeat Pump Installations Requiring Type 2 SPD Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1gvwdmy\" dir=\"auto\" data-start=\"7341\" data-end=\"7378\"\u003eWhy Choose the Lewden HPPI-R06W-A?\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"7380\" data-end=\"7578\"\u003eThe \u003cstrong data-start=\"7384\" data-end=\"7406\"\u003eLewden HPPI-R06W-A\u003c\/strong\u003e provides a practical way to create a dedicated electrical distribution point for an air source heat pump without assembling the core consumer unit components individually.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"7580\" data-end=\"7856\"\u003eIt comes equipped with a \u003cstrong data-start=\"7605\" data-end=\"7665\"\u003e100A main switch, B6 and B20 Type A RCBOs and Type 2 SPD\u003c\/strong\u003e, providing dedicated protection for heat pump controls and an immersion heater circuit while retaining spare capacity for additional heat pump circuits. \u003cspan class=\"contents\" data-content-reference-start=\"7657\" data-content-reference-end=\"7676\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"7858\" data-end=\"8086\"\u003eIts \u003cstrong data-start=\"7862\" data-end=\"7944\"\u003e6 usable ways, compact 9-module PRO enclosure and flexible round cable entries\u003c\/strong\u003e make it particularly suitable for professional ASHP installations where space, expandability and straightforward installation are priorities.\u003c\/p\u003e","brand":"Lewden","offers":[{"title":"Default Title","offer_id":54919732396378,"sku":"BHPPI-R06W-A","price":93.29,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/BHPPI-R06W-AC16_CAR_open_38e46177-9d53-4ab3-b40c-e2804651c3e5.png?v=1791375235","url":"https:\/\/account.alertelectrical.com\/products\/lewden-hppi-r06w-a-pro-6-way-heat-pump-ip20-consumer-unit-with-b6-b20-rcbos-and-type-2-spd","provider":"Alert Electrical","version":"1.0","type":"link"}