{"product_id":"lewden-hppi-r06w-ac16-pro-6-way-heat-pump-ip20-consumer-unit-with-16a-type-b-hp-rcbo-b6-b20-rcbos-and-spd","title":"Lewden HPPI-R06W-AC16 PRO 6 Way Heat Pump IP20 Consumer Unit with 16A Type B-HP RCBO, B6 \u0026 B20 RCBOs and SPD","description":"\u003ch1 data-section-id=\"nxrti\" dir=\"auto\" data-start=\"0\" data-end=\"105\" class=\"PDq2pG_selectionAnchorContainer\"\u003eLewden HPPI-R06W-AC16 PRO 6 Way Heat Pump Consumer Unit with 16A Type B-HP RCBO, B6 \u0026amp; B20 RCBOs and SPD\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2 data-section-id=\"1cs64g8\" dir=\"auto\" data-start=\"107\" data-end=\"182\"\u003ePurpose-Built Heat Pump Consumer Unit with Enhanced Type B-HP Protection\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"184\" data-end=\"559\"\u003eThe \u003cstrong data-start=\"188\" data-end=\"213\"\u003eLewden HPPI-R06W-AC16\u003c\/strong\u003e is a purpose-configured \u003cstrong data-start=\"238\" data-end=\"272\"\u003ePRO Series 6 way consumer unit\u003c\/strong\u003e designed for modern \u003cstrong data-start=\"293\" data-end=\"338\"\u003eair source heat pump (ASHP) installations\u003c\/strong\u003e. Supplied with a \u003cstrong data-start=\"356\" data-end=\"447\"\u003e16A Type B-HP heat pump RCBO, B6 and B20 Type A RCBOs, main switch and surge protection\u003c\/strong\u003e, it brings the key protective devices for a dedicated heat pump installation together in one compact enclosure.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"561\" data-end=\"925\"\u003eAt the heart of this configuration is Lewden's specialist \u003cstrong data-start=\"619\" data-end=\"636\"\u003e16A B-HP RCBO\u003c\/strong\u003e, designed for heat pump applications requiring enhanced Type B residual-current performance at higher frequencies. This makes the HPPI-R06W-AC16 particularly useful where the heat pump manufacturer's instructions call for this specialist protection rather than a conventional Type A RCBO.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" dir=\"auto\" data-start=\"927\" data-end=\"942\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"944\" data-end=\"1740\"\u003e\n\u003cli data-section-id=\"u6tkbb\" data-start=\"944\" data-end=\"987\"\u003eLewden PRO Series heat pump consumer unit\u003c\/li\u003e\n\u003cli data-section-id=\"gqnl1l\" data-start=\"988\" data-end=\"1017\"\u003eProduct code HPPI-R06W-AC16\u003c\/li\u003e\n\u003cli data-section-id=\"1cgv6kh\" data-start=\"1018\" data-end=\"1039\"\u003e6 way configuration\u003c\/li\u003e\n\u003cli data-section-id=\"1qh27mf\" data-start=\"1040\" data-end=\"1091\"\u003eSpecifically designed for heat pump installations\u003c\/li\u003e\n\u003cli data-section-id=\"bpox1\" data-start=\"1092\" data-end=\"1131\"\u003e16A Type B-HP Heat Pump RCBO included\u003c\/li\u003e\n\u003cli data-section-id=\"nkmmap\" data-start=\"1132\" data-end=\"1157\"\u003eB6 Type A RCBO included\u003c\/li\u003e\n\u003cli data-section-id=\"10pyvo5\" data-start=\"1158\" data-end=\"1184\"\u003eB20 Type A RCBO included\u003c\/li\u003e\n\u003cli data-section-id=\"lzjx2h\" data-start=\"1185\" data-end=\"1207\"\u003eMain switch included\u003c\/li\u003e\n\u003cli data-section-id=\"yo69el\" data-start=\"1208\" data-end=\"1242\"\u003eSurge Protection Device included\u003c\/li\u003e\n\u003cli data-section-id=\"dbpvgm\" data-start=\"1243\" data-end=\"1322\"\u003eEnhanced high-frequency residual-current protection for the heat pump circuit\u003c\/li\u003e\n\u003cli data-section-id=\"1lgfh6b\" data-start=\"1323\" data-end=\"1379\"\u003eType B-HP RCBO combines RCD and overcurrent protection\u003c\/li\u003e\n\u003cli data-section-id=\"1bmqwgl\" data-start=\"1380\" data-end=\"1416\"\u003e6kA breaking capacity on B-HP RCBO\u003c\/li\u003e\n\u003cli data-section-id=\"6v4md7\" data-start=\"1417\" data-end=\"1464\"\u003e30mA residual-current protection on B-HP RCBO\u003c\/li\u003e\n\u003cli data-section-id=\"o7olbh\" data-start=\"1465\" data-end=\"1491\"\u003eBi-directional B-HP RCBO\u003c\/li\u003e\n\u003cli data-section-id=\"10p0cfd\" data-start=\"1492\" data-end=\"1529\"\u003e1 pole + switched neutral B-HP RCBO\u003c\/li\u003e\n\u003cli data-section-id=\"42q9vg\" data-start=\"1530\" data-end=\"1576\"\u003eCompact single-module B-HP protective device\u003c\/li\u003e\n\u003cli data-section-id=\"sybliz\" data-start=\"1577\" data-end=\"1628\"\u003eSpare capacity for additional associated circuits\u003c\/li\u003e\n\u003cli data-section-id=\"c2bx2c\" data-start=\"1629\" data-end=\"1651\"\u003ePRO Series enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"1a4alxj\" data-start=\"1652\" data-end=\"1681\"\u003eDIN rail protective devices\u003c\/li\u003e\n\u003cli data-section-id=\"d70l13\" data-start=\"1682\" data-end=\"1740\"\u003eDedicated solution for modern inverter-driven heat pumps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1m9k1pk\" dir=\"auto\" data-start=\"1742\" data-end=\"1772\"\u003e16A Type B-HP RCBO Included\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"1774\" data-end=\"1870\"\u003eThe defining feature of the \u003cstrong data-start=\"1802\" data-end=\"1820\"\u003eHPPI-R06W-AC16\u003c\/strong\u003e is its included \u003cstrong data-start=\"1837\" data-end=\"1869\"\u003e16A Type B-HP Heat Pump RCBO\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1872\" data-end=\"2170\"\u003eRather than relying solely on a conventional Type A protective device for the main heat pump circuit, this configuration incorporates Lewden's specialist B-HP technology, developed for heat pump applications where the manufacturer's requirements specify enhanced Type B residual-current protection.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2172\" data-end=\"2341\"\u003eThe 16A device combines \u003cstrong data-start=\"2196\" data-end=\"2275\"\u003e30mA residual-current protection with overload and short-circuit protection\u003c\/strong\u003e, eliminating the need to pair a separate Type B RCCB with an MCB.\u003c\/p\u003e\n\u003ch2 data-section-id=\"hciofz\" dir=\"auto\" data-start=\"2343\" data-end=\"2402\"\u003eEnhanced Protection for High-Frequency Residual Currents\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"2404\" data-end=\"2641\"\u003eModern heat pumps frequently use inverter technology to control compressor operation. Depending on the equipment design, these systems can generate residual currents across a wider range of frequencies than conventional electrical loads.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2643\" data-end=\"2950\"\u003eLewden's B-HP range has been developed for heat pump manufacturers requiring enhanced Type B protection capable of catering for higher-frequency residual currents. The B-HP technology is designed for operation at frequencies of \u003cstrong data-start=\"2871\" data-end=\"2890\"\u003e20kHz and above\u003c\/strong\u003e, while addressing enhanced Type B requirements up to 20kHz.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2952\" data-end=\"3151\"\u003eWhere specified by the heat pump manufacturer, this provides a dedicated solution for residual-current characteristics that may not be appropriately addressed by more conventional protective devices.\u003c\/p\u003e\n\u003ch2 data-section-id=\"3evio7\" dir=\"auto\" data-start=\"3153\" data-end=\"3199\"\u003eCompact B-HP RCBO Saves Consumer Unit Space\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"3201\" data-end=\"3280\"\u003eA major advantage of Lewden's B-HP RCBO technology is its compact construction.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3282\" data-end=\"3421\"\u003eThe specialist heat pump RCBO occupies just \u003cstrong data-start=\"3326\" data-end=\"3345\"\u003eone 18mm module\u003c\/strong\u003e, despite combining residual-current, overload and short-circuit protection.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3423\" data-end=\"3680\"\u003eA conventional arrangement using a Type B RCCB alongside separate overcurrent protection can occupy approximately three modules. The B-HP RCBO therefore helps keep the HPPI-R06W-AC16 compact while retaining useful capacity for associated heat pump circuits.\u003c\/p\u003e\n\u003ch2 data-section-id=\"zsxqrm\" dir=\"auto\" data-start=\"3682\" data-end=\"3715\"\u003eB6 RCBO for Heat Pump Controls\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"3717\" data-end=\"3815\"\u003eAlongside the specialist 16A B-HP device, the consumer unit includes a \u003cstrong data-start=\"3788\" data-end=\"3814\"\u003e6A B Curve Type A RCBO\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3817\" data-end=\"3968\"\u003eThis device is intended for the associated \u003cstrong data-start=\"3860\" data-end=\"3889\"\u003eheat pump control circuit\u003c\/strong\u003e, providing individual residual-current, overload and short-circuit protection.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3970\" data-end=\"4122\"\u003eSeparate RCBO protection helps ensure that associated circuits are individually protected rather than relying on one shared RCD for every final circuit.\u003c\/p\u003e\n\u003ch2 data-section-id=\"b41zcr\" dir=\"auto\" data-start=\"4124\" data-end=\"4164\"\u003eB20 RCBO for Immersion Heater Circuit\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"4166\" data-end=\"4298\"\u003eA \u003cstrong data-start=\"4168\" data-end=\"4195\"\u003e20A B Curve Type A RCBO\u003c\/strong\u003e is also supplied, providing dedicated protection for an associated \u003cstrong data-start=\"4263\" data-end=\"4297\"\u003eimmersion heater final circuit\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4300\" data-end=\"4506\"\u003eTogether, the 16A B-HP RCBO, B6 RCBO and B20 RCBO provide a practical starting configuration for a heat pump installation comprising the principal heat pump supply, controls and associated immersion heater.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4508\" data-end=\"4627\"\u003eFinal circuit allocation must always follow the heat pump manufacturer's instructions and the electrical system design.\u003c\/p\u003e\n\u003ch2 data-section-id=\"10poo1z\" dir=\"auto\" data-start=\"4629\" data-end=\"4659\"\u003eIntegrated Surge Protection\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"4661\" data-end=\"4808\"\u003eThe HPPI-R06W-AC16 also incorporates \u003cstrong data-start=\"4698\" data-end=\"4718\"\u003esurge protection\u003c\/strong\u003e, helping protect the installation and connected equipment against transient overvoltages.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4810\" data-end=\"4970\"\u003eThis is particularly valuable for heat pump systems containing sophisticated electronic controls, inverter technology and other sensitive electronic components.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4972\" data-end=\"5108\"\u003eIntegrating the SPD within the dedicated consumer unit provides a neat solution without requiring a separate surge-protection enclosure.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1qna26w\" dir=\"auto\" data-start=\"5110\" data-end=\"5134\"\u003eMain Switch Isolation\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"5136\" data-end=\"5228\"\u003eA \u003cstrong data-start=\"5138\" data-end=\"5153\"\u003emain switch\u003c\/strong\u003e is included to provide isolation of the dedicated heat pump consumer unit.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5230\" data-end=\"5415\"\u003eThis allows the complete heat pump distribution arrangement to be isolated from one location while individual RCBOs provide protection and switching for their respective final circuits.\u003c\/p\u003e\n\u003ch2 data-section-id=\"qw7vqb\" dir=\"auto\" data-start=\"5417\" data-end=\"5452\"\u003eSix-Way PRO Series Configuration\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"5454\" data-end=\"5596\"\u003eThe \u003cstrong data-start=\"5458\" data-end=\"5481\"\u003e6 way configuration\u003c\/strong\u003e provides useful flexibility for heat pump installations involving more than the three supplied protected circuits.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5598\" data-end=\"5825\"\u003eIn addition to the included B-HP, B6 and B20 RCBOs, available capacity can be used for additional associated circuits where required by the heat pump system design and where compatible protective devices are correctly selected.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5827\" data-end=\"5953\"\u003ePotential additional circuits can include auxiliary or integral heater supplies, depending on the particular heat pump system.\u003c\/p\u003e\n\u003ch2 data-section-id=\"5gmtys\" dir=\"auto\" data-start=\"5955\" data-end=\"5997\"\u003eDesigned for Inverter-Driven Heat Pumps\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"5999\" data-end=\"6175\"\u003eThe HPPI-R06W-AC16 is particularly relevant to \u003cstrong data-start=\"6046\" data-end=\"6087\"\u003einverter-driven air source heat pumps\u003c\/strong\u003e where the equipment manufacturer specifies enhanced Type B residual-current protection.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"6177\" data-end=\"6453\"\u003eNot every heat pump requires Type B-HP protection. The RCD classification, RCBO current rating and overcurrent characteristic must therefore be selected according to the \u003cstrong data-start=\"6347\" data-end=\"6452\"\u003especific heat pump manufacturer's instructions, cable design and electrical installation requirements\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1cgu054\" dir=\"auto\" data-start=\"6455\" data-end=\"6482\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"6484\" data-end=\"7301\"\u003e\n\u003cli data-section-id=\"1wxzd3s\" data-start=\"6484\" data-end=\"6503\"\u003e\n\u003cstrong data-start=\"6486\" data-end=\"6496\"\u003eBrand:\u003c\/strong\u003e Lewden\u003c\/li\u003e\n\u003cli data-section-id=\"1e9tj8j\" data-start=\"6504\" data-end=\"6551\"\u003e\n\u003cstrong data-start=\"6506\" data-end=\"6516\"\u003eRange:\u003c\/strong\u003e PRO Series Heat Pump Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"5p6wnn\" data-start=\"6552\" data-end=\"6586\"\u003e\n\u003cstrong data-start=\"6554\" data-end=\"6571\"\u003eProduct Code:\u003c\/strong\u003e HPPI-R06W-AC16\u003c\/li\u003e\n\u003cli data-section-id=\"v3k6s9\" data-start=\"6587\" data-end=\"6630\"\u003e\n\u003cstrong data-start=\"6589\" data-end=\"6606\"\u003eProduct Type:\u003c\/strong\u003e Heat Pump Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"1ah4r0y\" data-start=\"6631\" data-end=\"6654\"\u003e\n\u003cstrong data-start=\"6633\" data-end=\"6652\"\u003eNumber of Ways:\u003c\/strong\u003e 6\u003c\/li\u003e\n\u003cli data-section-id=\"1mnzo4z\" data-start=\"6655\" data-end=\"6682\"\u003e\n\u003cstrong data-start=\"6657\" data-end=\"6673\"\u003eMain Switch:\u003c\/strong\u003e Included\u003c\/li\u003e\n\u003cli data-section-id=\"19g2xsm\" data-start=\"6683\" data-end=\"6713\"\u003e\n\u003cstrong data-start=\"6685\" data-end=\"6704\"\u003eHeat Pump RCBO:\u003c\/strong\u003e Included\u003c\/li\u003e\n\u003cli data-section-id=\"mpek27\" data-start=\"6714\" data-end=\"6746\"\u003e\n\u003cstrong data-start=\"6716\" data-end=\"6742\"\u003eHeat Pump RCBO Rating:\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli data-section-id=\"1cr1pnm\" data-start=\"6747\" data-end=\"6801\"\u003e\n\u003cstrong data-start=\"6749\" data-end=\"6773\"\u003eHeat Pump RCBO Type:\u003c\/strong\u003e Type B-HP \/ Enhanced Type B\u003c\/li\u003e\n\u003cli data-section-id=\"doj63d\" data-start=\"6802\" data-end=\"6845\"\u003e\n\u003cstrong data-start=\"6804\" data-end=\"6840\"\u003eHeat Pump RCBO Residual Current:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n\u003cli data-section-id=\"11ir7ix\" data-start=\"6846\" data-end=\"6889\"\u003e\n\u003cstrong data-start=\"6848\" data-end=\"6885\"\u003eHeat Pump RCBO Breaking Capacity:\u003c\/strong\u003e 6kA\u003c\/li\u003e\n\u003cli data-section-id=\"9rhn5u\" data-start=\"6890\" data-end=\"6956\"\u003e\n\u003cstrong data-start=\"6892\" data-end=\"6930\"\u003eHeat Pump RCBO Pole Configuration:\u003c\/strong\u003e 1 Pole + Switched Neutral\u003c\/li\u003e\n\u003cli data-section-id=\"w7o85r\" data-start=\"6957\" data-end=\"6997\"\u003e\n\u003cstrong data-start=\"6959\" data-end=\"6993\"\u003eHeat Pump RCBO Bi-Directional:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli data-section-id=\"1go6339\" data-start=\"6998\" data-end=\"7041\"\u003e\n\u003cstrong data-start=\"7000\" data-end=\"7025\"\u003eHeat Pump RCBO Width:\u003c\/strong\u003e 1 Module \/ 18mm\u003c\/li\u003e\n\u003cli data-section-id=\"1bl535t\" data-start=\"7042\" data-end=\"7089\"\u003e\n\u003cstrong data-start=\"7044\" data-end=\"7066\"\u003eAdditional RCBO 1:\u003c\/strong\u003e 6A B Curve Type A RCBO\u003c\/li\u003e\n\u003cli data-section-id=\"thss9i\" data-start=\"7090\" data-end=\"7138\"\u003e\n\u003cstrong data-start=\"7092\" data-end=\"7114\"\u003eAdditional RCBO 2:\u003c\/strong\u003e 20A B Curve Type A RCBO\u003c\/li\u003e\n\u003cli data-section-id=\"m92zen\" data-start=\"7139\" data-end=\"7171\"\u003e\n\u003cstrong data-start=\"7141\" data-end=\"7162\"\u003eSurge Protection:\u003c\/strong\u003e Included\u003c\/li\u003e\n\u003cli data-section-id=\"jci4bs\" data-start=\"7172\" data-end=\"7220\"\u003e\n\u003cstrong data-start=\"7174\" data-end=\"7187\"\u003eMounting:\u003c\/strong\u003e Surface \/ DIN Rail Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"1jpoh0w\" data-start=\"7221\" data-end=\"7301\"\u003e\n\u003cstrong data-start=\"7223\" data-end=\"7247\"\u003ePrimary Application:\u003c\/strong\u003e Heat Pump \/ ASHP Electrical Distribution \u0026amp; Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"11cc03h\" dir=\"auto\" data-start=\"7303\" data-end=\"7327\"\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul data-start=\"7329\" data-end=\"7733\"\u003e\n\u003cli data-section-id=\"fqu7i4\" data-start=\"7329\" data-end=\"7352\"\u003eAir Source Heat Pumps\u003c\/li\u003e\n\u003cli data-section-id=\"4lbrfx\" data-start=\"7353\" data-end=\"7373\"\u003eASHP Installations\u003c\/li\u003e\n\u003cli data-section-id=\"74meq9\" data-start=\"7374\" data-end=\"7402\"\u003eInverter-Driven Heat Pumps\u003c\/li\u003e\n\u003cli data-section-id=\"ff8tkv\" data-start=\"7403\" data-end=\"7446\"\u003eHeat Pumps Requiring Type B-HP Protection\u003c\/li\u003e\n\u003cli data-section-id=\"1ggy3ie\" data-start=\"7447\" data-end=\"7477\"\u003eDedicated Heat Pump Supplies\u003c\/li\u003e\n\u003cli data-section-id=\"z5dl1r\" data-start=\"7478\" data-end=\"7506\"\u003eHeat Pump Control Circuits\u003c\/li\u003e\n\u003cli data-section-id=\"s4lcsi\" data-start=\"7507\" data-end=\"7534\"\u003eImmersion Heater Circuits\u003c\/li\u003e\n\u003cli data-section-id=\"1t0x32h\" data-start=\"7535\" data-end=\"7569\"\u003eDomestic Heat Pump Installations\u003c\/li\u003e\n\u003cli data-section-id=\"1xpve3w\" data-start=\"7570\" data-end=\"7598\"\u003eLow-Carbon Heating Systems\u003c\/li\u003e\n\u003cli data-section-id=\"18wn2\" data-start=\"7599\" data-end=\"7632\"\u003eRenewable Heating Installations\u003c\/li\u003e\n\u003cli data-section-id=\"2lbvu3\" data-start=\"7633\" data-end=\"7662\"\u003eHeat Pump Retrofit Projects\u003c\/li\u003e\n\u003cli data-section-id=\"l467wg\" data-start=\"7663\" data-end=\"7698\"\u003eNew-Build Heat Pump Installations\u003c\/li\u003e\n\u003cli data-section-id=\"1svo5e1\" data-start=\"7699\" data-end=\"7733\"\u003eDedicated Heat Pump Distribution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1sprglq\" dir=\"auto\" data-start=\"7735\" data-end=\"7775\"\u003eWhy Choose the Lewden HPPI-R06W-AC16?\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"7777\" data-end=\"8137\"\u003eThe \u003cstrong data-start=\"7781\" data-end=\"7806\"\u003eLewden HPPI-R06W-AC16\u003c\/strong\u003e offers a significant advantage for heat pump installations requiring more than a standard collection of Type A RCBOs. Its inclusion of a dedicated \u003cstrong data-start=\"7954\" data-end=\"7976\"\u003e16A Type B-HP RCBO\u003c\/strong\u003e provides specialist residual-current protection for compatible inverter-driven heat pumps, while simultaneously providing overload and short-circuit protection.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"8139\" data-end=\"8387\"\u003eThe supplied \u003cstrong data-start=\"8152\" data-end=\"8179\"\u003eB6 and B20 Type A RCBOs\u003c\/strong\u003e provide individual protection for associated circuits such as heat pump controls and an immersion heater, while the \u003cstrong data-start=\"8296\" data-end=\"8330\"\u003emain switch and integrated SPD\u003c\/strong\u003e complete a practical dedicated distribution arrangement.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"8389\" data-end=\"8663\"\u003eFor installers, this means the principal heat pump protection components are brought together in a purpose-configured \u003cstrong data-start=\"8507\" data-end=\"8541\"\u003eLewden PRO 6 way consumer unit\u003c\/strong\u003e, reducing the need to assemble the arrangement from separate components while retaining capacity for additional circuits.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"8665\" data-end=\"8911\"\u003eMost importantly, the HPPI-R06W-AC16 should be selected where the \u003cstrong data-start=\"8731\" data-end=\"8910\"\u003eheat pump manufacturer's requirements and electrical design specify a 16A circuit with the enhanced Type B-HP protection characteristics provided by the included Lewden device\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Lewden","offers":[{"title":"Default Title","offer_id":54919737966938,"sku":"BHPPI-R06W-AC16","price":244.86,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/BHPPI-R06W-AC16_CAR_open_38e46177-9d53-4ab3-b40c-e2804651c3e5.png?v=1791375235","url":"https:\/\/account.alertelectrical.com\/products\/lewden-hppi-r06w-ac16-pro-6-way-heat-pump-ip20-consumer-unit-with-16a-type-b-hp-rcbo-b6-b20-rcbos-and-spd","provider":"Alert Electrical","version":"1.0","type":"link"}