{"product_id":"lewden-hppo-05mg-1-pro65-5-way-ip65-heat-pump-consumer-unit-with-100a-type-b-rcd-b6-b20-rcbos-and-spd","title":"Lewden HPPO-05MG-1 PRO65 5 Way IP65 Heat Pump Consumer Unit with 100A Type B RCD, B6 \u0026 B20 RCBOs and SPD","description":"\u003ch1 data-section-id=\"11hj93s\" dir=\"auto\" data-start=\"0\" data-end=\"106\" class=\"PDq2pG_selectionAnchorContainer\"\u003eLewden HPPO-05MG-1 PRO65 5 Way IP65 Heat Pump Consumer Unit with 100A Type B RCD, B6 \u0026amp; B20 RCBOs and SPD\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2 data-section-id=\"1ryrktl\" dir=\"auto\" data-start=\"108\" data-end=\"166\"\u003eIP65 Heat Pump Consumer Unit with Type B RCD Protection\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"168\" data-end=\"609\"\u003eThe \u003cstrong data-start=\"172\" data-end=\"194\"\u003eLewden HPPO-05MG-1\u003c\/strong\u003e is a robust \u003cstrong data-start=\"207\" data-end=\"236\"\u003ePRO65 5 way consumer unit\u003c\/strong\u003e purpose-designed for \u003cstrong data-start=\"258\" data-end=\"348\"\u003eair source heat pump (ASHP) installations requiring Type B residual-current protection\u003c\/strong\u003e. Supplied pre-configured with a \u003cstrong data-start=\"381\" data-end=\"480\"\u003e100A main switch, 100A Type B RCD, B6 and B20 Type A RCBOs and a Type 2 Surge Protection Device\u003c\/strong\u003e, it provides a comprehensive dedicated distribution solution for modern heat pump systems. \u003cspan class=\"contents\" data-content-reference-start=\"572\" data-content-reference-end=\"591\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"611\" data-end=\"896\"\u003eUnlike Lewden's indoor PRO heat pump consumer units, the HPPO-05MG-1 uses a durable \u003cstrong data-start=\"695\" data-end=\"732\"\u003eIP65 die-cast aluminium enclosure\u003c\/strong\u003e, making it suitable for indoor or outdoor applications where increased protection against dust and water ingress is required. \u003cspan class=\"contents\" data-content-reference-start=\"841\" data-content-reference-end=\"860\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" dir=\"auto\" data-start=\"898\" data-end=\"913\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"915\" data-end=\"1662\"\u003e\n\u003cli data-section-id=\"1sgyq7\" data-start=\"915\" data-end=\"953\"\u003eLewden PRO65 heat pump consumer unit\u003c\/li\u003e\n\u003cli data-section-id=\"tlnbrr\" data-start=\"954\" data-end=\"980\"\u003eProduct code HPPO-05MG-1\u003c\/li\u003e\n\u003cli data-section-id=\"1qjm99k\" data-start=\"981\" data-end=\"1030\"\u003eDesigned for air source heat pump installations\u003c\/li\u003e\n\u003cli data-section-id=\"1o6dtql\" data-start=\"1031\" data-end=\"1046\"\u003e5 usable ways\u003c\/li\u003e\n\u003cli data-section-id=\"1giucg4\" data-start=\"1047\" data-end=\"1068\"\u003e10-module enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"duu41y\" data-start=\"1069\" data-end=\"1094\"\u003eIP65 ingress protection\u003c\/li\u003e\n\u003cli data-section-id=\"181bw58\" data-start=\"1095\" data-end=\"1132\"\u003eRobust die-cast aluminium enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"1ywhm6h\" data-start=\"1133\" data-end=\"1179\"\u003eSuitable for indoor and outdoor applications\u003c\/li\u003e\n\u003cli data-section-id=\"z8prfb\" data-start=\"1180\" data-end=\"1200\"\u003e100A rated current\u003c\/li\u003e\n\u003cli data-section-id=\"fakzhz\" data-start=\"1201\" data-end=\"1220\"\u003e230V single-phase\u003c\/li\u003e\n\u003cli data-section-id=\"1uihn1b\" data-start=\"1221\" data-end=\"1250\"\u003e100A main switch \/ isolator\u003c\/li\u003e\n\u003cli data-section-id=\"198jl5b\" data-start=\"1251\" data-end=\"1277\"\u003e100A Type B RCD included\u003c\/li\u003e\n\u003cli data-section-id=\"1vw75av\" data-start=\"1278\" data-end=\"1311\"\u003e6A B Curve Type A RCBO included\u003c\/li\u003e\n\u003cli data-section-id=\"14zkt5v\" data-start=\"1312\" data-end=\"1346\"\u003e20A B Curve Type A RCBO included\u003c\/li\u003e\n\u003cli data-section-id=\"1to4a53\" data-start=\"1347\" data-end=\"1388\"\u003eType 2 Surge Protection Device included\u003c\/li\u003e\n\u003cli data-section-id=\"1u6sjso\" data-start=\"1389\" data-end=\"1425\"\u003eB6 RCBO intended for ASHP controls\u003c\/li\u003e\n\u003cli data-section-id=\"1u35jfr\" data-start=\"1426\" data-end=\"1480\"\u003eB20 RCBO intended for immersion heater final circuit\u003c\/li\u003e\n\u003cli data-section-id=\"a3xryb\" data-start=\"1481\" data-end=\"1527\"\u003eSpare ways for additional heat pump circuits\u003c\/li\u003e\n\u003cli data-section-id=\"hepged\" data-start=\"1528\" data-end=\"1557\"\u003eRound cable-entry knockouts\u003c\/li\u003e\n\u003cli data-section-id=\"76lip5\" data-start=\"1558\" data-end=\"1607\"\u003eSuitable for cable glands, conduit and grommets\u003c\/li\u003e\n\u003cli data-section-id=\"1m7nogq\" data-start=\"1608\" data-end=\"1644\"\u003eSuitable for SWA cable termination\u003c\/li\u003e\n\u003cli data-section-id=\"1xw5t75\" data-start=\"1645\" data-end=\"1662\"\u003eTop-hinged door\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"dng6qh\" dir=\"auto\" data-start=\"1664\" data-end=\"1693\"\u003e100A Type B RCD Protection\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"1695\" data-end=\"1969\"\u003eA key feature of the HPPO-05MG-1 is its included \u003cstrong data-start=\"1744\" data-end=\"1763\"\u003e100A Type B RCD\u003c\/strong\u003e, making this model suitable for heat pump installations where the equipment manufacturer or electrical design specifically requires Type B residual-current protection. \u003cspan class=\"contents\" data-content-reference-start=\"1896\" data-content-reference-end=\"1915\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1971\" data-end=\"2318\"\u003eModern inverter-driven heat pumps contain sophisticated power electronics that can produce residual-current waveforms beyond those associated with conventional electrical loads. Type B protection is designed for applications where residual currents may include smooth DC and other waveforms within the device's specified operating characteristics.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2320\" data-end=\"2489\"\u003eThe required RCD type should always be confirmed against the particular heat pump manufacturer's instructions rather than assuming every ASHP requires Type B protection.\u003c\/p\u003e\n\u003ch2 data-section-id=\"5thnkr\" dir=\"auto\" data-start=\"2491\" data-end=\"2531\"\u003eB6 Type A RCBO for Heat Pump Controls\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"2533\" data-end=\"2672\"\u003eThe HPPO-05MG-1 is supplied with a \u003cstrong data-start=\"2568\" data-end=\"2594\"\u003e6A B Curve Type A RCBO\u003c\/strong\u003e, intended for the ASHP control circuit. \u003cspan class=\"contents\" data-content-reference-start=\"2581\" data-content-reference-end=\"2600\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2674\" data-end=\"2874\"\u003eAs an RCBO, this device provides both residual-current and overcurrent protection for its individual final circuit, giving the heat pump controls dedicated circuit protection within the consumer unit.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1a4fbmq\" dir=\"auto\" data-start=\"2876\" data-end=\"2923\"\u003eB20 Type A RCBO for Immersion Heater Circuit\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"2925\" data-end=\"3063\"\u003eA \u003cstrong data-start=\"2927\" data-end=\"2954\"\u003e20A B Curve Type A RCBO\u003c\/strong\u003e is also supplied for an associated \u003cstrong data-start=\"2990\" data-end=\"3024\"\u003eimmersion heater final circuit\u003c\/strong\u003e. \u003cspan class=\"contents\" data-content-reference-start=\"2954\" data-content-reference-end=\"2973\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3065\" data-end=\"3252\"\u003eTogether, the B6 and B20 RCBOs provide a practical pre-populated arrangement for common associated heat pump circuits while leaving additional ways available for expansion where required.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1dzm5me\" dir=\"auto\" data-start=\"3254\" data-end=\"3289\"\u003eBuilt-In Type 2 Surge Protection\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"3291\" data-end=\"3493\"\u003eThe Lewden HPPO-05MG-1 incorporates a \u003cstrong data-start=\"3329\" data-end=\"3369\"\u003eType 2 Surge Protection Device (SPD)\u003c\/strong\u003e to help protect the installation and connected equipment from transient overvoltages. \u003cspan class=\"contents\" data-content-reference-start=\"3366\" data-content-reference-end=\"3385\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3495\" data-end=\"3646\"\u003eThis is particularly valuable for modern heat pump systems containing electronic control equipment, inverter technology and other sensitive components.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3648\" data-end=\"3798\"\u003eIntegrating the SPD within the consumer unit provides a neat, centralised protection solution without requiring a separate surge-protection enclosure.\u003c\/p\u003e\n\u003ch2 data-section-id=\"ak1dmu\" dir=\"auto\" data-start=\"3800\" data-end=\"3836\"\u003eIP65 Die-Cast Aluminium Enclosure\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"3838\" data-end=\"3948\"\u003eOne of the major advantages of the \u003cstrong data-start=\"3873\" data-end=\"3894\"\u003ePRO65 HPPO-05MG-1\u003c\/strong\u003e is its durable \u003cstrong data-start=\"3910\" data-end=\"3947\"\u003eIP65 die-cast aluminium enclosure\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3950\" data-end=\"4189\"\u003eThe IP65 rating provides a high degree of protection against dust and water ingress, making the consumer unit suitable for appropriately installed \u003cstrong data-start=\"4097\" data-end=\"4150\"\u003eexternal applications as well as indoor locations\u003c\/strong\u003e. \u003cspan class=\"contents\" data-content-reference-start=\"4044\" data-content-reference-end=\"4063\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4191\" data-end=\"4386\"\u003eThis makes it particularly useful where the dedicated heat pump distribution equipment needs to be positioned in a more demanding environment than a standard indoor consumer unit can accommodate.\u003c\/p\u003e\n\u003ch2 data-section-id=\"r8559o\" dir=\"auto\" data-start=\"4388\" data-end=\"4407\"\u003e100A Main Switch\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"4409\" data-end=\"4567\"\u003eThe consumer unit incorporates a \u003cstrong data-start=\"4442\" data-end=\"4473\"\u003e100A main switch \/ isolator\u003c\/strong\u003e, providing convenient isolation of the complete dedicated heat pump distribution arrangement.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4569\" data-end=\"4708\"\u003eLewden's configuration uses \u003cstrong data-start=\"4597\" data-end=\"4621\"\u003edual screw terminals\u003c\/strong\u003e to provide secure termination of incoming tails. \u003cspan class=\"contents\" data-content-reference-start=\"4545\" data-content-reference-end=\"4564\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1dd3bnt\" dir=\"auto\" data-start=\"4710\" data-end=\"4729\"\u003eFive Usable Ways\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"4731\" data-end=\"4889\"\u003eThe HPPO-05MG-1 provides \u003cstrong data-start=\"4756\" data-end=\"4773\"\u003e5 usable ways\u003c\/strong\u003e, allowing the supplied protective devices to be combined with additional heat pump-related circuits where required.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4891\" data-end=\"5111\"\u003eLewden identifies spare ways as suitable for additional circuits such as \u003cstrong data-start=\"4964\" data-end=\"4994\"\u003eintegral heat pump heaters\u003c\/strong\u003e, subject to the requirements of the connected equipment and electrical design. \u003cspan class=\"contents\" data-content-reference-start=\"4930\" data-content-reference-end=\"4949\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5113\" data-end=\"5226\"\u003eThis makes the unit more flexible than a tightly populated dedicated enclosure with no room for future expansion.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1u0fy84\" dir=\"auto\" data-start=\"5228\" data-end=\"5261\"\u003eInstaller-Friendly Cable Entry\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"5263\" data-end=\"5380\"\u003eThe enclosure incorporates \u003cstrong data-start=\"5290\" data-end=\"5309\"\u003eround knockouts\u003c\/strong\u003e designed for straightforward cable entry and professional termination.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5382\" data-end=\"5403\"\u003eThey can accommodate:\u003c\/p\u003e\n\u003cul data-start=\"5405\" data-end=\"5476\"\u003e\n\u003cli data-section-id=\"bs56cw\" data-start=\"5405\" data-end=\"5425\"\u003eRound cable glands\u003c\/li\u003e\n\u003cli data-section-id=\"60eoh2\" data-start=\"5426\" data-end=\"5435\"\u003eConduit\u003c\/li\u003e\n\u003cli data-section-id=\"yyq8zd\" data-start=\"5436\" data-end=\"5452\"\u003eCable grommets\u003c\/li\u003e\n\u003cli data-section-id=\"1lump1s\" data-start=\"5453\" data-end=\"5476\"\u003eSWA cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"5478\" data-end=\"5705\"\u003eThis is especially useful for an IP65 heat pump consumer unit, where correctly selected cable-entry accessories are important for maintaining the required level of environmental protection. \u003cspan class=\"contents\" data-content-reference-start=\"5506\" data-content-reference-end=\"5525\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1pyi2s1\" dir=\"auto\" data-start=\"5707\" data-end=\"5736\"\u003eCompact PRO65 Construction\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"5738\" data-end=\"5941\"\u003eDespite its robust metal construction and comprehensive protective-device configuration, the HPPO-05MG-1 maintains relatively compact dimensions of approximately \u003cstrong data-start=\"5900\" data-end=\"5940\"\u003e264mm high x 240mm wide x 105mm deep\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5943\" data-end=\"6074\"\u003eThe enclosure provides \u003cstrong data-start=\"5966\" data-end=\"5998\"\u003e10 modules and 5 usable ways\u003c\/strong\u003e, with a top-hinged door for access. \u003cspan class=\"contents\" data-content-reference-start=\"5855\" data-content-reference-end=\"5874\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1cgu054\" dir=\"auto\" data-start=\"6076\" data-end=\"6103\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"6105\" data-end=\"6949\"\u003e\n\u003cli data-section-id=\"1wxzd3s\" data-start=\"6105\" data-end=\"6124\"\u003e\n\u003cstrong data-start=\"6107\" data-end=\"6117\"\u003eBrand:\u003c\/strong\u003e Lewden\u003c\/li\u003e\n\u003cli data-section-id=\"1kgvwj\" data-start=\"6125\" data-end=\"6143\"\u003e\n\u003cstrong data-start=\"6127\" data-end=\"6137\"\u003eRange:\u003c\/strong\u003e PRO65\u003c\/li\u003e\n\u003cli data-section-id=\"13exwct\" data-start=\"6144\" data-end=\"6175\"\u003e\n\u003cstrong data-start=\"6146\" data-end=\"6163\"\u003eProduct Code:\u003c\/strong\u003e HPPO-05MG-1\u003c\/li\u003e\n\u003cli data-section-id=\"v3k6s9\" data-start=\"6176\" data-end=\"6219\"\u003e\n\u003cstrong data-start=\"6178\" data-end=\"6195\"\u003eProduct Type:\u003c\/strong\u003e Heat Pump Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"6w8qmk\" data-start=\"6220\" data-end=\"6281\"\u003e\n\u003cstrong data-start=\"6222\" data-end=\"6246\"\u003ePrimary Application:\u003c\/strong\u003e Air Source Heat Pump Installations\u003c\/li\u003e\n\u003cli data-section-id=\"1pszmq4\" data-start=\"6282\" data-end=\"6317\"\u003e\n\u003cstrong data-start=\"6284\" data-end=\"6312\"\u003eRated Operating Voltage:\u003c\/strong\u003e 230V\u003c\/li\u003e\n\u003cli data-section-id=\"1cl61ag\" data-start=\"6318\" data-end=\"6343\"\u003e\n\u003cstrong data-start=\"6320\" data-end=\"6330\"\u003ePhase:\u003c\/strong\u003e Single Phase\u003c\/li\u003e\n\u003cli data-section-id=\"fb648d\" data-start=\"6344\" data-end=\"6369\"\u003e\n\u003cstrong data-start=\"6346\" data-end=\"6364\"\u003eRated Current:\u003c\/strong\u003e 100A\u003c\/li\u003e\n\u003cli data-section-id=\"1b30mvx\" data-start=\"6370\" data-end=\"6400\"\u003e\n\u003cstrong data-start=\"6372\" data-end=\"6398\"\u003eNumber of Usable Ways:\u003c\/strong\u003e 5\u003c\/li\u003e\n\u003cli data-section-id=\"18hzmts\" data-start=\"6401\" data-end=\"6428\"\u003e\n\u003cstrong data-start=\"6403\" data-end=\"6425\"\u003eNumber of Modules:\u003c\/strong\u003e 10\u003c\/li\u003e\n\u003cli data-section-id=\"jwgf9y\" data-start=\"6429\" data-end=\"6450\"\u003e\n\u003cstrong data-start=\"6431\" data-end=\"6445\"\u003eIP Rating:\u003c\/strong\u003e IP65\u003c\/li\u003e\n\u003cli data-section-id=\"1ieae0w\" data-start=\"6451\" data-end=\"6495\"\u003e\n\u003cstrong data-start=\"6453\" data-end=\"6476\"\u003eEnclosure Material:\u003c\/strong\u003e Die-Cast Aluminium\u003c\/li\u003e\n\u003cli data-section-id=\"1gwjw9n\" data-start=\"6496\" data-end=\"6546\"\u003e\n\u003cstrong data-start=\"6498\" data-end=\"6518\"\u003eIncoming Device:\u003c\/strong\u003e 100A Main Switch \/ Isolator\u003c\/li\u003e\n\u003cli data-section-id=\"126mfh4\" data-start=\"6547\" data-end=\"6573\"\u003e\n\u003cstrong data-start=\"6549\" data-end=\"6557\"\u003eRCD:\u003c\/strong\u003e 100A Type B RCD\u003c\/li\u003e\n\u003cli data-section-id=\"o34f0g\" data-start=\"6574\" data-end=\"6619\"\u003e\n\u003cstrong data-start=\"6576\" data-end=\"6596\"\u003eIncluded RCBO 1:\u003c\/strong\u003e 6A B Curve Type A RCBO\u003c\/li\u003e\n\u003cli data-section-id=\"v7u8c7\" data-start=\"6620\" data-end=\"6666\"\u003e\n\u003cstrong data-start=\"6622\" data-end=\"6642\"\u003eIncluded RCBO 2:\u003c\/strong\u003e 20A B Curve Type A RCBO\u003c\/li\u003e\n\u003cli data-section-id=\"151lfrc\" data-start=\"6667\" data-end=\"6694\"\u003e\n\u003cstrong data-start=\"6669\" data-end=\"6690\"\u003eSurge Protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli data-section-id=\"1oxpy3r\" data-start=\"6695\" data-end=\"6717\"\u003e\n\u003cstrong data-start=\"6697\" data-end=\"6710\"\u003eSPD Type:\u003c\/strong\u003e Type 2\u003c\/li\u003e\n\u003cli data-section-id=\"plhsah\" data-start=\"6718\" data-end=\"6769\"\u003e\n\u003cstrong data-start=\"6720\" data-end=\"6735\"\u003eDimensions:\u003c\/strong\u003e 264mm (H) x 240mm (W) x 105mm (D)\u003c\/li\u003e\n\u003cli data-section-id=\"1el1dge\" data-start=\"6770\" data-end=\"6797\"\u003e\n\u003cstrong data-start=\"6772\" data-end=\"6786\"\u003eDoor Type:\u003c\/strong\u003e Top Hinged\u003c\/li\u003e\n\u003cli data-section-id=\"oho93m\" data-start=\"6798\" data-end=\"6832\"\u003e\n\u003cstrong data-start=\"6800\" data-end=\"6816\"\u003eCable Entry:\u003c\/strong\u003e Round Knockouts\u003c\/li\u003e\n\u003cli data-section-id=\"1tlw64k\" data-start=\"6833\" data-end=\"6925\"\u003e\n\u003cstrong data-start=\"6835\" data-end=\"6858\"\u003eIndoor\/Outdoor Use:\u003c\/strong\u003e Yes, subject to correct installation and maintaining the IP rating\u003c\/li\u003e\n\u003cli data-section-id=\"50imk6\" data-start=\"6926\" data-end=\"6949\"\u003e\n\u003cstrong data-start=\"6928\" data-end=\"6942\"\u003eGuarantee:\u003c\/strong\u003e 1 Year\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"6951\" data-end=\"7154\"\u003eThe exact HPPO-05MG-1 configuration is independently listed with the \u003cstrong data-start=\"7020\" data-end=\"7113\"\u003e100A Type B RCD, B6 and B20 Type A RCBOs, Type 2 SPD, five usable ways and IP65 enclosure\u003c\/strong\u003e. \u003cspan class=\"contents\" data-content-reference-start=\"6915\" data-content-reference-end=\"6947\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"11cc03h\" dir=\"auto\" data-start=\"7156\" data-end=\"7180\"\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul data-start=\"7182\" data-end=\"7653\"\u003e\n\u003cli data-section-id=\"1bc001s\" data-start=\"7182\" data-end=\"7218\"\u003eAir Source Heat Pump Installations\u003c\/li\u003e\n\u003cli data-section-id=\"ipb992\" data-start=\"7219\" data-end=\"7249\"\u003eASHP Electrical Distribution\u003c\/li\u003e\n\u003cli data-section-id=\"74meq9\" data-start=\"7250\" data-end=\"7278\"\u003eInverter-Driven Heat Pumps\u003c\/li\u003e\n\u003cli data-section-id=\"9vx5hb\" data-start=\"7279\" data-end=\"7323\"\u003eHeat Pumps Requiring Type B RCD Protection\u003c\/li\u003e\n\u003cli data-section-id=\"dwefi3\" data-start=\"7324\" data-end=\"7358\"\u003eOutdoor Heat Pump Consumer Units\u003c\/li\u003e\n\u003cli data-section-id=\"rkr7pw\" data-start=\"7359\" data-end=\"7394\"\u003eExternal Electrical Installations\u003c\/li\u003e\n\u003cli data-section-id=\"z5dl1r\" data-start=\"7395\" data-end=\"7423\"\u003eHeat Pump Control Circuits\u003c\/li\u003e\n\u003cli data-section-id=\"s4lcsi\" data-start=\"7424\" data-end=\"7451\"\u003eImmersion Heater Circuits\u003c\/li\u003e\n\u003cli data-section-id=\"sdh37t\" data-start=\"7452\" data-end=\"7488\"\u003eIntegral Heat Pump Heater Circuits\u003c\/li\u003e\n\u003cli data-section-id=\"1t0x32h\" data-start=\"7489\" data-end=\"7523\"\u003eDomestic Heat Pump Installations\u003c\/li\u003e\n\u003cli data-section-id=\"4llumz\" data-start=\"7524\" data-end=\"7560\"\u003eCommercial Heat Pump Installations\u003c\/li\u003e\n\u003cli data-section-id=\"18xptev\" data-start=\"7561\" data-end=\"7588\"\u003eRenewable Heating Systems\u003c\/li\u003e\n\u003cli data-section-id=\"1d0mm9h\" data-start=\"7589\" data-end=\"7623\"\u003eLow-Carbon Heating Installations\u003c\/li\u003e\n\u003cli data-section-id=\"2lbvu3\" data-start=\"7624\" data-end=\"7653\"\u003eHeat Pump Retrofit Projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1kbhms0\" dir=\"auto\" data-start=\"7655\" data-end=\"7692\"\u003eWhy Choose the Lewden HPPO-05MG-1?\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"7694\" data-end=\"7881\"\u003eThe \u003cstrong data-start=\"7698\" data-end=\"7720\"\u003eLewden HPPO-05MG-1\u003c\/strong\u003e provides a particularly useful solution where a dedicated heat pump consumer unit needs both \u003cstrong data-start=\"7814\" data-end=\"7880\"\u003eType B residual-current protection and a robust IP65 enclosure\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"7883\" data-end=\"8142\"\u003eIts pre-configured arrangement brings together a \u003cstrong data-start=\"7932\" data-end=\"8009\"\u003e100A Type B RCD, B6 and B20 Type A RCBOs, 100A main switch and Type 2 SPD\u003c\/strong\u003e, reducing the need to assemble the principal heat pump distribution components individually. \u003cspan class=\"contents\" data-content-reference-start=\"7896\" data-content-reference-end=\"7915\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"8144\" data-end=\"8356\"\u003eThe \u003cstrong data-start=\"8148\" data-end=\"8191\"\u003eIP65 die-cast aluminium PRO65 enclosure\u003c\/strong\u003e is a key advantage over standard indoor consumer units, providing increased environmental protection for correctly installed external or demanding indoor locations.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"8358\" data-end=\"8614\"\u003eWith \u003cstrong data-start=\"8363\" data-end=\"8380\"\u003e5 usable ways\u003c\/strong\u003e, spare capacity for additional heat pump circuits and installer-friendly round knockouts for glands, conduit and SWA termination, the HPPO-05MG-1 provides a robust and flexible distribution solution for compatible ASHP installations.\u003c\/p\u003e","brand":"Lewden","offers":[{"title":"Default Title","offer_id":54919742357850,"sku":"BHPPO-05MG-1","price":220.48,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/BHPPO-05MG-1_CAL-open.png?v=1791375828","url":"https:\/\/account.alertelectrical.com\/products\/lewden-hppo-05mg-1-pro65-5-way-ip65-heat-pump-consumer-unit-with-100a-type-b-rcd-b6-b20-rcbos-and-spd","provider":"Alert Electrical","version":"1.0","type":"link"}