{"product_id":"lewden-hppo-07mg-a-pro65-7-way-ip65-heat-pump-consumer-unit-with-b6-b20-rcbos-and-type-2-spd","title":"Lewden HPPO-07MG-A PRO65 7 Way IP65 Heat Pump Consumer Unit with B6 \u0026 B20 RCBOs and Type 2 SPD","description":"\u003ch1 data-section-id=\"ahuakx\" dir=\"auto\" data-start=\"0\" data-end=\"96\" class=\"PDq2pG_selectionAnchorContainer\"\u003eLewden HPPO-07MG-A PRO65 7 Way IP65 Heat Pump Consumer Unit with B6 \u0026amp; B20 RCBOs and Type 2 SPD\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2 data-section-id=\"vhc6vt\" dir=\"auto\" data-start=\"98\" data-end=\"165\"\u003eRobust IP65 Consumer Unit for Air Source Heat Pump Installations\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"167\" data-end=\"563\"\u003eThe \u003cstrong data-start=\"171\" data-end=\"193\"\u003eLewden HPPO-07MG-A\u003c\/strong\u003e is a purpose-configured \u003cstrong data-start=\"218\" data-end=\"257\"\u003ePRO65 7 way heat pump consumer unit\u003c\/strong\u003e designed for modern \u003cstrong data-start=\"278\" data-end=\"323\"\u003eair source heat pump (ASHP) installations\u003c\/strong\u003e. Supplied with a \u003cstrong data-start=\"341\" data-end=\"423\"\u003e100A main switch, B6 and B20 Type A RCBOs and built-in Type 2 surge protection\u003c\/strong\u003e, it provides a practical dedicated distribution solution for heat pump controls, immersion heater circuits and additional associated loads.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"565\" data-end=\"925\"\u003eWith \u003cstrong data-start=\"570\" data-end=\"587\"\u003e7 usable ways\u003c\/strong\u003e, the HPPO-07MG-A offers generous capacity for expanding the heat pump installation, while its \u003cstrong data-start=\"682\" data-end=\"700\"\u003eIP65 enclosure\u003c\/strong\u003e provides enhanced protection against dust and water ingress. The exact model is specified at \u003cstrong data-start=\"794\" data-end=\"825\"\u003e230V, single phase and 100A\u003c\/strong\u003e, with a compact 10-module format measuring 264 x 240 x 105mm. \u003cspan class=\"contents\" data-content-reference-start=\"888\" data-content-reference-end=\"907\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" dir=\"auto\" data-start=\"927\" data-end=\"942\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"944\" data-end=\"1674\"\u003e\n\u003cli data-section-id=\"1sgyq7\" data-start=\"944\" data-end=\"982\"\u003eLewden PRO65 heat pump consumer unit\u003c\/li\u003e\n\u003cli data-section-id=\"tkbh5x\" data-start=\"983\" data-end=\"1009\"\u003eProduct code HPPO-07MG-A\u003c\/li\u003e\n\u003cli data-section-id=\"1qjm99k\" data-start=\"1010\" data-end=\"1059\"\u003eDesigned for air source heat pump installations\u003c\/li\u003e\n\u003cli data-section-id=\"1mf1vpr\" data-start=\"1060\" data-end=\"1075\"\u003e7 usable ways\u003c\/li\u003e\n\u003cli data-section-id=\"1giucg4\" data-start=\"1076\" data-end=\"1097\"\u003e10-module enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"duu41y\" data-start=\"1098\" data-end=\"1123\"\u003eIP65 ingress protection\u003c\/li\u003e\n\u003cli data-section-id=\"z8prfb\" data-start=\"1124\" data-end=\"1144\"\u003e100A rated current\u003c\/li\u003e\n\u003cli data-section-id=\"1etcv0i\" data-start=\"1145\" data-end=\"1174\"\u003e230V single-phase operation\u003c\/li\u003e\n\u003cli data-section-id=\"1uihn1b\" data-start=\"1175\" data-end=\"1204\"\u003e100A main switch \/ isolator\u003c\/li\u003e\n\u003cli data-section-id=\"nkmmap\" data-start=\"1205\" data-end=\"1230\"\u003eB6 Type A RCBO included\u003c\/li\u003e\n\u003cli data-section-id=\"10pyvo5\" data-start=\"1231\" data-end=\"1257\"\u003eB20 Type A RCBO included\u003c\/li\u003e\n\u003cli data-section-id=\"1to4a53\" data-start=\"1258\" data-end=\"1299\"\u003eType 2 Surge Protection Device included\u003c\/li\u003e\n\u003cli data-section-id=\"1u6sjso\" data-start=\"1300\" data-end=\"1336\"\u003eB6 RCBO intended for ASHP controls\u003c\/li\u003e\n\u003cli data-section-id=\"1u35jfr\" data-start=\"1337\" data-end=\"1391\"\u003eB20 RCBO intended for immersion heater final circuit\u003c\/li\u003e\n\u003cli data-section-id=\"a3xryb\" data-start=\"1392\" data-end=\"1438\"\u003eSpare ways for additional heat pump circuits\u003c\/li\u003e\n\u003cli data-section-id=\"hepged\" data-start=\"1439\" data-end=\"1468\"\u003eRound cable-entry knockouts\u003c\/li\u003e\n\u003cli data-section-id=\"18ofjxc\" data-start=\"1469\" data-end=\"1524\"\u003eSuitable for cable glands, conduit and cable grommets\u003c\/li\u003e\n\u003cli data-section-id=\"1m7nogq\" data-start=\"1525\" data-end=\"1561\"\u003eSuitable for SWA cable termination\u003c\/li\u003e\n\u003cli data-section-id=\"1xw5t75\" data-start=\"1562\" data-end=\"1579\"\u003eTop-hinged door\u003c\/li\u003e\n\u003cli data-section-id=\"9sy9bb\" data-start=\"1580\" data-end=\"1617\"\u003eCompact 264 x 240 x 105mm enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"es85do\" data-start=\"1618\" data-end=\"1674\"\u003e1-year guarantee \u003cspan class=\"contents\" data-content-reference-start=\"1619\" data-content-reference-end=\"1638\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"zmqdi5\" dir=\"auto\" data-start=\"1676\" data-end=\"1716\"\u003ePre-Configured for ASHP Installations\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"1718\" data-end=\"1848\"\u003eThe HPPO-07MG-A brings the principal distribution components for a dedicated heat pump installation together within one enclosure.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1850\" data-end=\"2130\"\u003eIt is supplied with a \u003cstrong data-start=\"1872\" data-end=\"1892\"\u003e100A main switch\u003c\/strong\u003e, plus \u003cstrong data-start=\"1899\" data-end=\"1934\"\u003e6A and 20A B Curve Type A RCBOs\u003c\/strong\u003e intended for the ASHP controls and immersion heater final circuits respectively. An integrated \u003cstrong data-start=\"2030\" data-end=\"2044\"\u003eType 2 SPD\u003c\/strong\u003e provides surge protection for the installation. \u003cspan class=\"contents\" data-content-reference-start=\"2057\" data-content-reference-end=\"2076\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2132\" data-end=\"2293\"\u003eThis pre-populated arrangement can reduce the amount of individual component selection required while still leaving spare ways available for additional circuits.\u003c\/p\u003e\n\u003ch2 data-section-id=\"5thnkr\" dir=\"auto\" data-start=\"2295\" data-end=\"2335\"\u003eB6 Type A RCBO for Heat Pump Controls\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"2337\" data-end=\"2451\"\u003eA \u003cstrong data-start=\"2339\" data-end=\"2365\"\u003e6A B Curve Type A RCBO\u003c\/strong\u003e is pre-fitted for the \u003cstrong data-start=\"2388\" data-end=\"2412\"\u003eASHP control circuit\u003c\/strong\u003e. \u003cspan class=\"contents\" data-content-reference-start=\"2360\" data-content-reference-end=\"2379\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2453\" data-end=\"2703\"\u003eThe RCBO combines residual-current protection with overload and short-circuit protection for its individual circuit, providing a dedicated protective device for the heat pump controls rather than placing multiple final circuits behind one shared RCD.\u003c\/p\u003e\n\u003ch2 data-section-id=\"ofi1bl\" dir=\"auto\" data-start=\"2705\" data-end=\"2744\"\u003eB20 Type A RCBO for Immersion Heater\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"2746\" data-end=\"2910\"\u003eThe consumer unit also includes a \u003cstrong data-start=\"2780\" data-end=\"2807\"\u003e20A B Curve Type A RCBO\u003c\/strong\u003e, specified for an associated \u003cstrong data-start=\"2837\" data-end=\"2871\"\u003eimmersion heater final circuit\u003c\/strong\u003e. \u003cspan class=\"contents\" data-content-reference-start=\"2801\" data-content-reference-end=\"2820\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2912\" data-end=\"3065\"\u003eTogether, the B6 and B20 devices provide a useful starting configuration for the associated circuits commonly required alongside an air source heat pump.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3067\" data-end=\"3235\"\u003eThe final circuit arrangement and protective-device selection should always follow the requirements of the specific heat pump manufacturer and electrical system design.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1dzm5me\" dir=\"auto\" data-start=\"3237\" data-end=\"3272\"\u003eBuilt-In Type 2 Surge Protection\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"3274\" data-end=\"3485\"\u003eA \u003cstrong data-start=\"3276\" data-end=\"3316\"\u003eType 2 Surge Protection Device (SPD)\u003c\/strong\u003e is incorporated into the HPPO-07MG-A to help protect connected electrical and electronic equipment against transient overvoltages. \u003cspan class=\"contents\" data-content-reference-start=\"3358\" data-content-reference-end=\"3377\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3487\" data-end=\"3688\"\u003eModern heat pumps can contain sophisticated electronic controls and inverter technology, making properly selected surge protection an important consideration within the overall electrical installation.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3690\" data-end=\"3821\"\u003eIntegrating the SPD into the dedicated heat pump consumer unit creates a neat, centralised distribution and protection arrangement.\u003c\/p\u003e\n\u003ch2 data-section-id=\"r8559o\" dir=\"auto\" data-start=\"3823\" data-end=\"3842\"\u003e100A Main Switch\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"3844\" data-end=\"3988\"\u003eThe HPPO-07MG-A incorporates a \u003cstrong data-start=\"3875\" data-end=\"3906\"\u003e100A main switch \/ isolator\u003c\/strong\u003e, providing a convenient means of isolating the dedicated heat pump consumer unit.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3990\" data-end=\"4123\"\u003eThe incoming switch features \u003cstrong data-start=\"4019\" data-end=\"4043\"\u003edual screw terminals\u003c\/strong\u003e for secure termination of incoming tails. \u003cspan class=\"contents\" data-content-reference-start=\"3978\" data-content-reference-end=\"3997\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"16lh6nw\" dir=\"auto\" data-start=\"4125\" data-end=\"4169\"\u003eSeven Usable Ways for Additional Circuits\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"4171\" data-end=\"4290\"\u003eWith \u003cstrong data-start=\"4176\" data-end=\"4193\"\u003e7 usable ways\u003c\/strong\u003e, this PRO65 consumer unit provides useful flexibility for more involved heat pump installations.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4292\" data-end=\"4581\"\u003eOnce the supplied B6 and B20 RCBOs and associated devices are accounted for, spare capacity is available for additional heat pump circuits. Lewden's product information identifies \u003cstrong data-start=\"4472\" data-end=\"4500\"\u003eintegral heater circuits\u003c\/strong\u003e as one potential use for these spare ways. \u003cspan class=\"contents\" data-content-reference-start=\"4418\" data-content-reference-end=\"4437\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4583\" data-end=\"4724\"\u003eAny additional protective devices should be selected according to the connected load, cable design and heat pump manufacturer's requirements.\u003c\/p\u003e\n\u003ch2 data-section-id=\"yxyia6\" dir=\"auto\" data-start=\"4726\" data-end=\"4768\"\u003eIP65 Protection for Demanding Locations\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"4770\" data-end=\"4891\"\u003eA major advantage of the \u003cstrong data-start=\"4795\" data-end=\"4810\"\u003eHPPO-07MG-A\u003c\/strong\u003e over standard indoor heat pump consumer units is its \u003cstrong data-start=\"4864\" data-end=\"4890\"\u003eIP65 protection rating\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4893\" data-end=\"5060\"\u003eThe enclosure therefore offers enhanced resistance to dust and water ingress, making it a strong choice where the consumer unit needs greater environmental protection.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5062\" data-end=\"5196\"\u003eCorrect installation and suitably rated cable glands and entry accessories are essential to maintaining the specified IP65 protection.\u003c\/p\u003e\n\u003ch2 data-section-id=\"fnafds\" dir=\"auto\" data-start=\"5198\" data-end=\"5234\"\u003eCompact 10-Module PRO65 Enclosure\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"5236\" data-end=\"5413\"\u003eThe HPPO-07MG-A provides its 7 usable ways within a compact \u003cstrong data-start=\"5296\" data-end=\"5319\"\u003e10-module enclosure\u003c\/strong\u003e, helping minimise the wall space required for the dedicated heat pump distribution equipment.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5415\" data-end=\"5452\"\u003eThe enclosure measures approximately:\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5454\" data-end=\"5491\"\u003e\u003cstrong data-start=\"5454\" data-end=\"5491\"\u003e264mm (H) x 240mm (W) x 105mm (D)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5493\" data-end=\"5596\"\u003eIt also incorporates a \u003cstrong data-start=\"5516\" data-end=\"5535\"\u003etop-hinged door\u003c\/strong\u003e for convenient access. \u003cspan class=\"contents\" data-content-reference-start=\"5415\" data-content-reference-end=\"5434\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1acmvl9\" dir=\"auto\" data-start=\"5598\" data-end=\"5621\"\u003eFlexible Cable Entry\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"5623\" data-end=\"5772\"\u003eThe enclosure features \u003cstrong data-start=\"5646\" data-end=\"5665\"\u003eround knockouts\u003c\/strong\u003e designed to simplify professional cable entry and termination. These are suitable for installations using:\u003c\/p\u003e\n\u003cul data-start=\"5774\" data-end=\"5839\"\u003e\n\u003cli data-section-id=\"14jo5ea\" data-start=\"5774\" data-end=\"5788\"\u003eCable glands\u003c\/li\u003e\n\u003cli data-section-id=\"60eoh2\" data-start=\"5789\" data-end=\"5798\"\u003eConduit\u003c\/li\u003e\n\u003cli data-section-id=\"yyq8zd\" data-start=\"5799\" data-end=\"5815\"\u003eCable grommets\u003c\/li\u003e\n\u003cli data-section-id=\"1lump1s\" data-start=\"5816\" data-end=\"5839\"\u003eSWA cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"5841\" data-end=\"5993\"\u003eThis gives installers flexibility when integrating the consumer unit into different heat pump wiring arrangements. \u003cspan class=\"contents\" data-content-reference-start=\"5794\" data-content-reference-end=\"5813\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1q4jsk6\" dir=\"auto\" data-start=\"5995\" data-end=\"6032\"\u003eImportant Protection Consideration\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"6034\" data-end=\"6397\"\u003eUnlike the \u003cstrong data-start=\"6045\" data-end=\"6060\"\u003eHPPO-05MG-1\u003c\/strong\u003e, which incorporates a Type B RCD, and the HPPO-07MG-AC16\/AC25 variants, which incorporate specialist heat pump RCBOs, the \u003cstrong data-start=\"6183\" data-end=\"6286\"\u003eHPPO-07MG-A is supplied with B6 and B20 Type A RCBOs and does not include a Type B RCD or B-HP RCBO\u003c\/strong\u003e. Current listings distinguish these models as separate configurations. \u003cspan class=\"contents\" data-content-reference-start=\"6178\" data-content-reference-end=\"6210\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"6399\" data-end=\"6653\"\u003eThis distinction is important when specifying a consumer unit for an inverter-driven heat pump. The HPPO-07MG-A should only be selected where its protective-device arrangement satisfies the heat pump manufacturer's requirements and the electrical design.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1cgu054\" dir=\"auto\" data-start=\"6655\" data-end=\"6682\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"6684\" data-end=\"7393\"\u003e\n\u003cli data-section-id=\"1wxzd3s\" data-start=\"6684\" data-end=\"6703\"\u003e\n\u003cstrong data-start=\"6686\" data-end=\"6696\"\u003eBrand:\u003c\/strong\u003e Lewden\u003c\/li\u003e\n\u003cli data-section-id=\"1kgvwj\" data-start=\"6704\" data-end=\"6722\"\u003e\n\u003cstrong data-start=\"6706\" data-end=\"6716\"\u003eRange:\u003c\/strong\u003e PRO65\u003c\/li\u003e\n\u003cli data-section-id=\"13askcf\" data-start=\"6723\" data-end=\"6754\"\u003e\n\u003cstrong data-start=\"6725\" data-end=\"6742\"\u003eProduct Code:\u003c\/strong\u003e HPPO-07MG-A\u003c\/li\u003e\n\u003cli data-section-id=\"v3k6s9\" data-start=\"6755\" data-end=\"6798\"\u003e\n\u003cstrong data-start=\"6757\" data-end=\"6774\"\u003eProduct Type:\u003c\/strong\u003e Heat Pump Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"6w8qmk\" data-start=\"6799\" data-end=\"6860\"\u003e\n\u003cstrong data-start=\"6801\" data-end=\"6825\"\u003ePrimary Application:\u003c\/strong\u003e Air Source Heat Pump Installations\u003c\/li\u003e\n\u003cli data-section-id=\"1pszmq4\" data-start=\"6861\" data-end=\"6896\"\u003e\n\u003cstrong data-start=\"6863\" data-end=\"6891\"\u003eRated Operating Voltage:\u003c\/strong\u003e 230V\u003c\/li\u003e\n\u003cli data-section-id=\"1cl61ag\" data-start=\"6897\" data-end=\"6922\"\u003e\n\u003cstrong data-start=\"6899\" data-end=\"6909\"\u003ePhase:\u003c\/strong\u003e Single Phase\u003c\/li\u003e\n\u003cli data-section-id=\"fb648d\" data-start=\"6923\" data-end=\"6948\"\u003e\n\u003cstrong data-start=\"6925\" data-end=\"6943\"\u003eRated Current:\u003c\/strong\u003e 100A\u003c\/li\u003e\n\u003cli data-section-id=\"np00l1\" data-start=\"6949\" data-end=\"6969\"\u003e\n\u003cstrong data-start=\"6951\" data-end=\"6967\"\u003eUsable Ways:\u003c\/strong\u003e 7\u003c\/li\u003e\n\u003cli data-section-id=\"18hzmts\" data-start=\"6970\" data-end=\"6997\"\u003e\n\u003cstrong data-start=\"6972\" data-end=\"6994\"\u003eNumber of Modules:\u003c\/strong\u003e 10\u003c\/li\u003e\n\u003cli data-section-id=\"jwgf9y\" data-start=\"6998\" data-end=\"7019\"\u003e\n\u003cstrong data-start=\"7000\" data-end=\"7014\"\u003eIP Rating:\u003c\/strong\u003e IP65\u003c\/li\u003e\n\u003cli data-section-id=\"1gwjw9n\" data-start=\"7020\" data-end=\"7070\"\u003e\n\u003cstrong data-start=\"7022\" data-end=\"7042\"\u003eIncoming Device:\u003c\/strong\u003e 100A Main Switch \/ Isolator\u003c\/li\u003e\n\u003cli data-section-id=\"o34f0g\" data-start=\"7071\" data-end=\"7116\"\u003e\n\u003cstrong data-start=\"7073\" data-end=\"7093\"\u003eIncluded RCBO 1:\u003c\/strong\u003e 6A B Curve Type A RCBO\u003c\/li\u003e\n\u003cli data-section-id=\"v7u8c7\" data-start=\"7117\" data-end=\"7163\"\u003e\n\u003cstrong data-start=\"7119\" data-end=\"7139\"\u003eIncluded RCBO 2:\u003c\/strong\u003e 20A B Curve Type A RCBO\u003c\/li\u003e\n\u003cli data-section-id=\"151lfrc\" data-start=\"7164\" data-end=\"7191\"\u003e\n\u003cstrong data-start=\"7166\" data-end=\"7187\"\u003eSurge Protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli data-section-id=\"1oxpy3r\" data-start=\"7192\" data-end=\"7214\"\u003e\n\u003cstrong data-start=\"7194\" data-end=\"7207\"\u003eSPD Type:\u003c\/strong\u003e Type 2\u003c\/li\u003e\n\u003cli data-section-id=\"plhsah\" data-start=\"7215\" data-end=\"7266\"\u003e\n\u003cstrong data-start=\"7217\" data-end=\"7232\"\u003eDimensions:\u003c\/strong\u003e 264mm (H) x 240mm (W) x 105mm (D)\u003c\/li\u003e\n\u003cli data-section-id=\"1el1dge\" data-start=\"7267\" data-end=\"7294\"\u003e\n\u003cstrong data-start=\"7269\" data-end=\"7283\"\u003eDoor Type:\u003c\/strong\u003e Top Hinged\u003c\/li\u003e\n\u003cli data-section-id=\"oho93m\" data-start=\"7295\" data-end=\"7329\"\u003e\n\u003cstrong data-start=\"7297\" data-end=\"7313\"\u003eCable Entry:\u003c\/strong\u003e Round Knockouts\u003c\/li\u003e\n\u003cli data-section-id=\"10x8pxn\" data-start=\"7330\" data-end=\"7393\"\u003e\n\u003cstrong data-start=\"7332\" data-end=\"7346\"\u003eGuarantee:\u003c\/strong\u003e 1 Year \u003cspan class=\"contents\" data-content-reference-start=\"7167\" data-content-reference-end=\"7186\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"11cc03h\" dir=\"auto\" data-start=\"7395\" data-end=\"7419\"\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul data-start=\"7421\" data-end=\"7837\"\u003e\n\u003cli data-section-id=\"1bc001s\" data-start=\"7421\" data-end=\"7457\"\u003eAir Source Heat Pump Installations\u003c\/li\u003e\n\u003cli data-section-id=\"ipb992\" data-start=\"7458\" data-end=\"7488\"\u003eASHP Electrical Distribution\u003c\/li\u003e\n\u003cli data-section-id=\"1ggy3ie\" data-start=\"7489\" data-end=\"7519\"\u003eDedicated Heat Pump Supplies\u003c\/li\u003e\n\u003cli data-section-id=\"z5dl1r\" data-start=\"7520\" data-end=\"7548\"\u003eHeat Pump Control Circuits\u003c\/li\u003e\n\u003cli data-section-id=\"s4lcsi\" data-start=\"7549\" data-end=\"7576\"\u003eImmersion Heater Circuits\u003c\/li\u003e\n\u003cli data-section-id=\"sdh37t\" data-start=\"7577\" data-end=\"7613\"\u003eIntegral Heat Pump Heater Circuits\u003c\/li\u003e\n\u003cli data-section-id=\"f5jc1p\" data-start=\"7614\" data-end=\"7644\"\u003eIP65 Heat Pump Installations\u003c\/li\u003e\n\u003cli data-section-id=\"1spauvk\" data-start=\"7645\" data-end=\"7673\"\u003eDomestic Heat Pump Systems\u003c\/li\u003e\n\u003cli data-section-id=\"oz85yb\" data-start=\"7674\" data-end=\"7705\"\u003eResidential Renewable Heating\u003c\/li\u003e\n\u003cli data-section-id=\"4llumz\" data-start=\"7706\" data-end=\"7742\"\u003eCommercial Heat Pump Installations\u003c\/li\u003e\n\u003cli data-section-id=\"1xpve3w\" data-start=\"7743\" data-end=\"7771\"\u003eLow-Carbon Heating Systems\u003c\/li\u003e\n\u003cli data-section-id=\"2lbvu3\" data-start=\"7772\" data-end=\"7801\"\u003eHeat Pump Retrofit Projects\u003c\/li\u003e\n\u003cli data-section-id=\"l467wg\" data-start=\"7802\" data-end=\"7837\"\u003eNew-Build Heat Pump Installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1j3mllu\" dir=\"auto\" data-start=\"7839\" data-end=\"7876\"\u003eWhy Choose the Lewden HPPO-07MG-A?\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"7878\" data-end=\"8107\"\u003eThe \u003cstrong data-start=\"7882\" data-end=\"7904\"\u003eLewden HPPO-07MG-A\u003c\/strong\u003e offers a convenient way to create a dedicated electrical distribution point for a heat pump installation while providing significantly more environmental protection than a conventional indoor enclosure.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"8109\" data-end=\"8372\"\u003eIts \u003cstrong data-start=\"8113\" data-end=\"8173\"\u003e100A main switch, B6 and B20 Type A RCBOs and Type 2 SPD\u003c\/strong\u003e are already incorporated, providing protection for the intended ASHP control and immersion heater circuits alongside surge protection for sensitive equipment. \u003cspan class=\"contents\" data-content-reference-start=\"8126\" data-content-reference-end=\"8145\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"8374\" data-end=\"8718\"\u003eWith \u003cstrong data-start=\"8379\" data-end=\"8396\"\u003e7 usable ways\u003c\/strong\u003e, there is also capacity for additional heat pump-related circuits where required. Combined with its \u003cstrong data-start=\"8497\" data-end=\"8563\"\u003e230V single-phase, 100A specification and IP65 PRO65 enclosure\u003c\/strong\u003e, the HPPO-07MG-A is a versatile choice for compatible ASHP installations where additional enclosure protection and future circuit capacity are priorities.\u003c\/p\u003e","brand":"Lewden","offers":[{"title":"Default Title","offer_id":54919745798490,"sku":"BHPPO-07MG-A","price":131.81,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/BHPPO-07MG-A_CAL-open.png?v=1791375932","url":"https:\/\/account.alertelectrical.com\/products\/lewden-hppo-07mg-a-pro65-7-way-ip65-heat-pump-consumer-unit-with-b6-b20-rcbos-and-type-2-spd","provider":"Alert Electrical","version":"1.0","type":"link"}