{"product_id":"lewden-hppo-07mg-ac16-pro65-7-way-ip65-heat-pump-consumer-unit-with-c16-type-b-hp-rcbo-b6-b20-rcbos-and-spd","title":"Lewden HPPO-07MG-AC16 PRO65 7 Way IP65 Heat Pump Consumer Unit with C16 Type B-HP RCBO, B6 \u0026 B20 RCBOs and SPD","description":"\u003ch1 data-section-id=\"15zfvyc\" dir=\"auto\" data-start=\"0\" data-end=\"112\" class=\"PDq2pG_selectionAnchorContainer\"\u003eLewden HPPO-07MG-AC16 PRO65 7 Way IP65 Heat Pump Consumer Unit with C16 Type B-HP RCBO, B6 \u0026amp; B20 RCBOs and SPD\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2 data-section-id=\"uvbjtb\" dir=\"auto\" data-start=\"114\" data-end=\"175\"\u003eIP65 Heat Pump Consumer Unit with 16A Type B-HP Protection\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"177\" data-end=\"591\"\u003eThe \u003cstrong data-start=\"181\" data-end=\"206\"\u003eLewden HPPO-07MG-AC16\u003c\/strong\u003e is a purpose-configured \u003cstrong data-start=\"231\" data-end=\"270\"\u003ePRO65 7 way heat pump consumer unit\u003c\/strong\u003e designed for modern \u003cstrong data-start=\"291\" data-end=\"336\"\u003eair source heat pump (ASHP) installations\u003c\/strong\u003e. Combining a specialist \u003cstrong data-start=\"361\" data-end=\"401\"\u003e16A C Curve Type B-HP Heat Pump RCBO\u003c\/strong\u003e, B6 and B20 Type A RCBOs, a \u003cstrong data-start=\"430\" data-end=\"450\"\u003e100A main switch\u003c\/strong\u003e and integrated \u003cstrong data-start=\"466\" data-end=\"493\"\u003eType 2 surge protection\u003c\/strong\u003e, it provides a comprehensive distribution and protection solution within a robust IP65 enclosure.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"593\" data-end=\"873\"\u003eDesigned for inverter-driven heat pump systems where enhanced Type B residual-current protection is specified, the HPPO-07MG-AC16 provides \u003cstrong data-start=\"732\" data-end=\"749\"\u003e7 usable ways\u003c\/strong\u003e, leaving useful capacity for additional associated circuits such as integral heaters. \u003cspan class=\"contents\" data-content-reference-start=\"836\" data-content-reference-end=\"868\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" dir=\"auto\" data-start=\"875\" data-end=\"890\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"892\" data-end=\"1770\"\u003e\n\u003cli data-section-id=\"1sgyq7\" data-start=\"892\" data-end=\"930\"\u003eLewden PRO65 heat pump consumer unit\u003c\/li\u003e\n\u003cli data-section-id=\"1ayz6xt\" data-start=\"931\" data-end=\"960\"\u003eProduct code HPPO-07MG-AC16\u003c\/li\u003e\n\u003cli data-section-id=\"1qjm99k\" data-start=\"961\" data-end=\"1010\"\u003eDesigned for air source heat pump installations\u003c\/li\u003e\n\u003cli data-section-id=\"1mf1vpr\" data-start=\"1011\" data-end=\"1026\"\u003e7 usable ways\u003c\/li\u003e\n\u003cli data-section-id=\"1giucg4\" data-start=\"1027\" data-end=\"1048\"\u003e10-module enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"duu41y\" data-start=\"1049\" data-end=\"1074\"\u003eIP65 ingress protection\u003c\/li\u003e\n\u003cli data-section-id=\"z8prfb\" data-start=\"1075\" data-end=\"1095\"\u003e100A rated current\u003c\/li\u003e\n\u003cli data-section-id=\"1etcv0i\" data-start=\"1096\" data-end=\"1125\"\u003e230V single-phase operation\u003c\/li\u003e\n\u003cli data-section-id=\"1uihn1b\" data-start=\"1126\" data-end=\"1155\"\u003e100A main switch \/ isolator\u003c\/li\u003e\n\u003cli data-section-id=\"1jke4lj\" data-start=\"1156\" data-end=\"1195\"\u003eC16 Type B-HP Heat Pump RCBO included\u003c\/li\u003e\n\u003cli data-section-id=\"nkmmap\" data-start=\"1196\" data-end=\"1221\"\u003eB6 Type A RCBO included\u003c\/li\u003e\n\u003cli data-section-id=\"10pyvo5\" data-start=\"1222\" data-end=\"1248\"\u003eB20 Type A RCBO included\u003c\/li\u003e\n\u003cli data-section-id=\"1to4a53\" data-start=\"1249\" data-end=\"1290\"\u003eType 2 Surge Protection Device included\u003c\/li\u003e\n\u003cli data-section-id=\"1monl3o\" data-start=\"1291\" data-end=\"1371\"\u003eEnhanced residual-current protection for compatible inverter-driven heat pumps\u003c\/li\u003e\n\u003cli data-section-id=\"c2tewb\" data-start=\"1372\" data-end=\"1420\"\u003eHigh-frequency operation up to 20kHz and above\u003c\/li\u003e\n\u003cli data-section-id=\"e1v1q3\" data-start=\"1421\" data-end=\"1465\"\u003eMinimum tripping point of 150mA above 1kHz\u003c\/li\u003e\n\u003cli data-section-id=\"1u6sjso\" data-start=\"1466\" data-end=\"1502\"\u003eB6 RCBO intended for ASHP controls\u003c\/li\u003e\n\u003cli data-section-id=\"1u35jfr\" data-start=\"1503\" data-end=\"1557\"\u003eB20 RCBO intended for immersion heater final circuit\u003c\/li\u003e\n\u003cli data-section-id=\"a3xryb\" data-start=\"1558\" data-end=\"1604\"\u003eSpare ways for additional heat pump circuits\u003c\/li\u003e\n\u003cli data-section-id=\"hepged\" data-start=\"1605\" data-end=\"1634\"\u003eRound cable-entry knockouts\u003c\/li\u003e\n\u003cli data-section-id=\"1ddsail\" data-start=\"1635\" data-end=\"1695\"\u003eSuitable for glands, conduit, grommets and SWA termination\u003c\/li\u003e\n\u003cli data-section-id=\"1xw5t75\" data-start=\"1696\" data-end=\"1713\"\u003eTop-hinged door\u003c\/li\u003e\n\u003cli data-section-id=\"9sy9bb\" data-start=\"1714\" data-end=\"1751\"\u003eCompact 264 x 240 x 105mm enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"m7tnnl\" data-start=\"1752\" data-end=\"1770\"\u003e1-year guarantee\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"11ma8k2\" dir=\"auto\" data-start=\"1772\" data-end=\"1803\"\u003eC16 Type B-HP Heat Pump RCBO\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"1805\" data-end=\"1904\"\u003eThe key protective device within the HPPO-07MG-AC16 is the supplied \u003cstrong data-start=\"1873\" data-end=\"1903\"\u003e16A C Curve Heat Pump RCBO\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1906\" data-end=\"2177\"\u003eLewden's specialist \u003cstrong data-start=\"1926\" data-end=\"1955\"\u003eType B-HP RCBO technology\u003c\/strong\u003e is designed for heat pump applications requiring enhanced residual-current protection at higher frequencies. The RCBO combines \u003cstrong data-start=\"2083\" data-end=\"2142\"\u003eresidual-current, overload and short-circuit protection\u003c\/strong\u003e within a single protective device.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2179\" data-end=\"2532\"\u003eCurrent product information for the exact HPPO-07MG-AC16 confirms a \u003cstrong data-start=\"2247\" data-end=\"2269\"\u003eC16 Heat Pump RCBO\u003c\/strong\u003e, so the \"C\" designation should not be confused with its residual-current classification: \u003cstrong data-start=\"2359\" data-end=\"2370\"\u003eC Curve\u003c\/strong\u003e refers to its overcurrent tripping characteristic, while \u003cstrong data-start=\"2428\" data-end=\"2441\"\u003eType B-HP\u003c\/strong\u003e describes its specialist residual-current behaviour. \u003cspan class=\"contents\" data-content-reference-start=\"2490\" data-content-reference-end=\"2509\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"5gmtys\" dir=\"auto\" data-start=\"2534\" data-end=\"2576\"\u003eDesigned for Inverter-Driven Heat Pumps\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"2578\" data-end=\"2816\"\u003eModern heat pumps frequently incorporate variable-speed inverter-driven compressors and sophisticated power electronics. These can produce residual-current characteristics across a wider frequency range than conventional electrical loads.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2818\" data-end=\"3063\"\u003eThe HPPO-07MG-AC16 is specifically described for \u003cstrong data-start=\"2867\" data-end=\"2969\"\u003eASHP installations with inverter-driven compressors operating at frequencies up to 20kHz and above\u003c\/strong\u003e, with a minimum tripping point of \u003cstrong data-start=\"3004\" data-end=\"3024\"\u003e150mA above 1kHz\u003c\/strong\u003e. \u003cspan class=\"contents\" data-content-reference-start=\"3003\" data-content-reference-end=\"3022\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3065\" data-end=\"3186\"\u003eThis makes the consumer unit particularly suitable where the heat pump manufacturer specifies enhanced Type B protection.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3188\" data-end=\"3396\"\u003eNot every heat pump requires Type B-HP protection, so the required RCBO type and rating should always be selected in accordance with the heat pump manufacturer's instructions and the electrical system design.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1a77h0x\" dir=\"auto\" data-start=\"3398\" data-end=\"3433\"\u003eB6 Type A RCBO for ASHP Controls\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"3435\" data-end=\"3591\"\u003eIn addition to the specialist C16 heat pump RCBO, the consumer unit is supplied with a \u003cstrong data-start=\"3522\" data-end=\"3548\"\u003e6A B Curve Type A RCBO\u003c\/strong\u003e intended for the \u003cstrong data-start=\"3566\" data-end=\"3590\"\u003eASHP control circuit\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3593\" data-end=\"3815\"\u003eThe RCBO provides individual residual-current, overload and short-circuit protection for this associated circuit, helping create a clearly organised heat pump distribution arrangement. \u003cspan class=\"contents\" data-content-reference-start=\"3737\" data-content-reference-end=\"3756\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"ofi1bl\" dir=\"auto\" data-start=\"3817\" data-end=\"3856\"\u003eB20 Type A RCBO for Immersion Heater\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"3858\" data-end=\"3974\"\u003eA \u003cstrong data-start=\"3860\" data-end=\"3887\"\u003e20A B Curve Type A RCBO\u003c\/strong\u003e is also supplied and is intended for an associated \u003cstrong data-start=\"3939\" data-end=\"3973\"\u003eimmersion heater final circuit\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3976\" data-end=\"4219\"\u003eTogether, the C16 B-HP RCBO, B6 Type A RCBO and B20 Type A RCBO provide dedicated protection for three key elements of a typical heat pump installation while leaving spare capacity for additional circuits. \u003cspan class=\"contents\" data-content-reference-start=\"4123\" data-content-reference-end=\"4142\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1dzm5me\" dir=\"auto\" data-start=\"4221\" data-end=\"4256\"\u003eBuilt-In Type 2 Surge Protection\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"4258\" data-end=\"4432\"\u003eThe HPPO-07MG-AC16 incorporates a \u003cstrong data-start=\"4292\" data-end=\"4332\"\u003eType 2 Surge Protection Device (SPD)\u003c\/strong\u003e to help protect the installation and connected electronic equipment against transient overvoltages.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4434\" data-end=\"4638\"\u003eHeat pump systems can incorporate sensitive inverter electronics, controllers and other electronic components, making properly selected surge protection an important part of the overall electrical design.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4640\" data-end=\"4844\"\u003eWith the SPD integrated into the consumer unit, the installation benefits from a neat centralised arrangement without requiring a separate surge-protection enclosure. \u003cspan class=\"contents\" data-content-reference-start=\"4730\" data-content-reference-end=\"4749\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"r8559o\" dir=\"auto\" data-start=\"4846\" data-end=\"4865\"\u003e100A Main Switch\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"4867\" data-end=\"4981\"\u003eA \u003cstrong data-start=\"4869\" data-end=\"4900\"\u003e100A main switch \/ isolator\u003c\/strong\u003e provides convenient isolation of the complete dedicated heat pump consumer unit.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4983\" data-end=\"5123\"\u003eThe main switch incorporates \u003cstrong data-start=\"5012\" data-end=\"5036\"\u003edual screw terminals\u003c\/strong\u003e to provide secure termination of incoming tails. \u003cspan class=\"contents\" data-content-reference-start=\"4991\" data-content-reference-end=\"5010\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1k0cp0q\" dir=\"auto\" data-start=\"5125\" data-end=\"5169\"\u003eSeven Usable Ways for Greater Flexibility\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"5171\" data-end=\"5316\"\u003eThe \u003cstrong data-start=\"5175\" data-end=\"5192\"\u003e7 usable ways\u003c\/strong\u003e make the HPPO-07MG-AC16 particularly flexible for heat pump installations requiring several associated electrical circuits.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5318\" data-end=\"5507\"\u003eWith the principal heat pump, controls and immersion heater protective devices already supplied, the remaining capacity can accommodate additional heat pump-related circuits where required.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5509\" data-end=\"5658\"\u003eLewden specifically identifies the spare ways as suitable for additional circuits such as \u003cstrong data-start=\"5599\" data-end=\"5619\"\u003eintegral heaters\u003c\/strong\u003e. \u003cspan class=\"contents\" data-content-reference-start=\"5508\" data-content-reference-end=\"5527\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"5660\" data-end=\"5816\"\u003eAny additional RCBOs or other protective devices should be selected according to the connected load, cable design and equipment manufacturer's requirements.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1d1021o\" dir=\"auto\" data-start=\"5818\" data-end=\"5836\"\u003eIP65 Protection\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"5838\" data-end=\"6016\"\u003eA major benefit of the \u003cstrong data-start=\"5861\" data-end=\"5881\"\u003ePRO65 HPPO range\u003c\/strong\u003e is the \u003cstrong data-start=\"5889\" data-end=\"5907\"\u003eIP65 enclosure\u003c\/strong\u003e, providing increased protection against dust and water ingress compared with standard indoor consumer units.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"6018\" data-end=\"6183\"\u003eThis makes the HPPO-07MG-AC16 particularly useful where the dedicated heat pump electrical distribution equipment needs to be installed in a more demanding location.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"6185\" data-end=\"6307\"\u003eCorrect installation, cable glands and entry accessories are essential to maintaining the enclosure's specified IP rating.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1xwnqa6\" dir=\"auto\" data-start=\"6309\" data-end=\"6339\"\u003eCompact 10-Module Enclosure\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"6341\" data-end=\"6460\"\u003eDespite providing \u003cstrong data-start=\"6359\" data-end=\"6376\"\u003e7 usable ways\u003c\/strong\u003e, the HPPO-07MG-AC16 uses a compact \u003cstrong data-start=\"6412\" data-end=\"6435\"\u003e10-module enclosure\u003c\/strong\u003e measuring approximately:\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"6462\" data-end=\"6502\"\u003e\u003cstrong data-start=\"6462\" data-end=\"6502\"\u003e264mm high x 240mm wide x 105mm deep\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"6504\" data-end=\"6704\"\u003eThe compact format helps reduce the wall space required for a dedicated heat pump distribution arrangement while retaining room for additional protective devices. \u003cspan class=\"contents\" data-content-reference-start=\"6536\" data-content-reference-end=\"6555\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1u0fy84\" dir=\"auto\" data-start=\"6706\" data-end=\"6739\"\u003eInstaller-Friendly Cable Entry\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"6741\" data-end=\"6859\"\u003eThe enclosure features \u003cstrong data-start=\"6764\" data-end=\"6783\"\u003eround knockouts\u003c\/strong\u003e designed to accommodate common professional cable-entry methods, including:\u003c\/p\u003e\n\u003cul data-start=\"6861\" data-end=\"6926\"\u003e\n\u003cli data-section-id=\"14jo5ea\" data-start=\"6861\" data-end=\"6875\"\u003eCable glands\u003c\/li\u003e\n\u003cli data-section-id=\"60eoh2\" data-start=\"6876\" data-end=\"6885\"\u003eConduit\u003c\/li\u003e\n\u003cli data-section-id=\"yyq8zd\" data-start=\"6886\" data-end=\"6902\"\u003eCable grommets\u003c\/li\u003e\n\u003cli data-section-id=\"1lump1s\" data-start=\"6903\" data-end=\"6926\"\u003eSWA cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"6928\" data-end=\"7164\"\u003eThis gives installers flexibility when positioning and wiring the consumer unit while allowing correctly selected glands and accessories to be used to maintain the required environmental protection. \u003cspan class=\"contents\" data-content-reference-start=\"6978\" data-content-reference-end=\"6997\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1cgu054\" dir=\"auto\" data-start=\"7166\" data-end=\"7193\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"7195\" data-end=\"8098\"\u003e\n\u003cli data-section-id=\"1wxzd3s\" data-start=\"7195\" data-end=\"7214\"\u003e\n\u003cstrong data-start=\"7197\" data-end=\"7207\"\u003eBrand:\u003c\/strong\u003e Lewden\u003c\/li\u003e\n\u003cli data-section-id=\"1kgvwj\" data-start=\"7215\" data-end=\"7233\"\u003e\n\u003cstrong data-start=\"7217\" data-end=\"7227\"\u003eRange:\u003c\/strong\u003e PRO65\u003c\/li\u003e\n\u003cli data-section-id=\"a2ks1n\" data-start=\"7234\" data-end=\"7268\"\u003e\n\u003cstrong data-start=\"7236\" data-end=\"7253\"\u003eProduct Code:\u003c\/strong\u003e HPPO-07MG-AC16\u003c\/li\u003e\n\u003cli data-section-id=\"v3k6s9\" data-start=\"7269\" data-end=\"7312\"\u003e\n\u003cstrong data-start=\"7271\" data-end=\"7288\"\u003eProduct Type:\u003c\/strong\u003e Heat Pump Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"6w8qmk\" data-start=\"7313\" data-end=\"7374\"\u003e\n\u003cstrong data-start=\"7315\" data-end=\"7339\"\u003ePrimary Application:\u003c\/strong\u003e Air Source Heat Pump Installations\u003c\/li\u003e\n\u003cli data-section-id=\"1pszmq4\" data-start=\"7375\" data-end=\"7410\"\u003e\n\u003cstrong data-start=\"7377\" data-end=\"7405\"\u003eRated Operating Voltage:\u003c\/strong\u003e 230V\u003c\/li\u003e\n\u003cli data-section-id=\"1cl61ag\" data-start=\"7411\" data-end=\"7436\"\u003e\n\u003cstrong data-start=\"7413\" data-end=\"7423\"\u003ePhase:\u003c\/strong\u003e Single Phase\u003c\/li\u003e\n\u003cli data-section-id=\"fb648d\" data-start=\"7437\" data-end=\"7462\"\u003e\n\u003cstrong data-start=\"7439\" data-end=\"7457\"\u003eRated Current:\u003c\/strong\u003e 100A\u003c\/li\u003e\n\u003cli data-section-id=\"np00l1\" data-start=\"7463\" data-end=\"7483\"\u003e\n\u003cstrong data-start=\"7465\" data-end=\"7481\"\u003eUsable Ways:\u003c\/strong\u003e 7\u003c\/li\u003e\n\u003cli data-section-id=\"18hzmts\" data-start=\"7484\" data-end=\"7511\"\u003e\n\u003cstrong data-start=\"7486\" data-end=\"7508\"\u003eNumber of Modules:\u003c\/strong\u003e 10\u003c\/li\u003e\n\u003cli data-section-id=\"jwgf9y\" data-start=\"7512\" data-end=\"7533\"\u003e\n\u003cstrong data-start=\"7514\" data-end=\"7528\"\u003eIP Rating:\u003c\/strong\u003e IP65\u003c\/li\u003e\n\u003cli data-section-id=\"1gwjw9n\" data-start=\"7534\" data-end=\"7584\"\u003e\n\u003cstrong data-start=\"7536\" data-end=\"7556\"\u003eIncoming Device:\u003c\/strong\u003e 100A Main Switch \/ Isolator\u003c\/li\u003e\n\u003cli data-section-id=\"mpek27\" data-start=\"7585\" data-end=\"7617\"\u003e\n\u003cstrong data-start=\"7587\" data-end=\"7613\"\u003eHeat Pump RCBO Rating:\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli data-section-id=\"1ac4o7h\" data-start=\"7618\" data-end=\"7653\"\u003e\n\u003cstrong data-start=\"7620\" data-end=\"7645\"\u003eHeat Pump RCBO Curve:\u003c\/strong\u003e C Curve\u003c\/li\u003e\n\u003cli data-section-id=\"1cr1pnm\" data-start=\"7654\" data-end=\"7708\"\u003e\n\u003cstrong data-start=\"7656\" data-end=\"7680\"\u003eHeat Pump RCBO Type:\u003c\/strong\u003e Type B-HP \/ Enhanced Type B\u003c\/li\u003e\n\u003cli data-section-id=\"1bl535t\" data-start=\"7709\" data-end=\"7756\"\u003e\n\u003cstrong data-start=\"7711\" data-end=\"7733\"\u003eAdditional RCBO 1:\u003c\/strong\u003e 6A B Curve Type A RCBO\u003c\/li\u003e\n\u003cli data-section-id=\"thss9i\" data-start=\"7757\" data-end=\"7805\"\u003e\n\u003cstrong data-start=\"7759\" data-end=\"7781\"\u003eAdditional RCBO 2:\u003c\/strong\u003e 20A B Curve Type A RCBO\u003c\/li\u003e\n\u003cli data-section-id=\"151lfrc\" data-start=\"7806\" data-end=\"7833\"\u003e\n\u003cstrong data-start=\"7808\" data-end=\"7829\"\u003eSurge Protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli data-section-id=\"1oxpy3r\" data-start=\"7834\" data-end=\"7856\"\u003e\n\u003cstrong data-start=\"7836\" data-end=\"7849\"\u003eSPD Type:\u003c\/strong\u003e Type 2\u003c\/li\u003e\n\u003cli data-section-id=\"1bvm9em\" data-start=\"7857\" data-end=\"7912\"\u003e\n\u003cstrong data-start=\"7859\" data-end=\"7890\"\u003eHigh-Frequency Application:\u003c\/strong\u003e Up to 20kHz and Above\u003c\/li\u003e\n\u003cli data-section-id=\"8dfl60\" data-start=\"7913\" data-end=\"7959\"\u003e\n\u003cstrong data-start=\"7915\" data-end=\"7953\"\u003eMinimum Tripping Point Above 1kHz:\u003c\/strong\u003e 150mA\u003c\/li\u003e\n\u003cli data-section-id=\"plhsah\" data-start=\"7960\" data-end=\"8011\"\u003e\n\u003cstrong data-start=\"7962\" data-end=\"7977\"\u003eDimensions:\u003c\/strong\u003e 264mm (H) x 240mm (W) x 105mm (D)\u003c\/li\u003e\n\u003cli data-section-id=\"1el1dge\" data-start=\"8012\" data-end=\"8039\"\u003e\n\u003cstrong data-start=\"8014\" data-end=\"8028\"\u003eDoor Type:\u003c\/strong\u003e Top Hinged\u003c\/li\u003e\n\u003cli data-section-id=\"oho93m\" data-start=\"8040\" data-end=\"8074\"\u003e\n\u003cstrong data-start=\"8042\" data-end=\"8058\"\u003eCable Entry:\u003c\/strong\u003e Round Knockouts\u003c\/li\u003e\n\u003cli data-section-id=\"50imk6\" data-start=\"8075\" data-end=\"8098\"\u003e\n\u003cstrong data-start=\"8077\" data-end=\"8091\"\u003eGuarantee:\u003c\/strong\u003e 1 Year\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"8100\" data-end=\"8337\"\u003eThe 100A main switch, C16 heat pump RCBO, B6 and B20 Type A RCBOs, Type 2 SPD, seven usable ways, 10-module enclosure and dimensions are confirmed by a current listing for the exact HPPO-07MG-AC16. \u003cspan class=\"contents\" data-content-reference-start=\"8131\" data-content-reference-end=\"8150\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"11cc03h\" dir=\"auto\" data-start=\"8339\" data-end=\"8363\"\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul data-start=\"8365\" data-end=\"8852\"\u003e\n\u003cli data-section-id=\"1bc001s\" data-start=\"8365\" data-end=\"8401\"\u003eAir Source Heat Pump Installations\u003c\/li\u003e\n\u003cli data-section-id=\"ipb992\" data-start=\"8402\" data-end=\"8432\"\u003eASHP Electrical Distribution\u003c\/li\u003e\n\u003cli data-section-id=\"74meq9\" data-start=\"8433\" data-end=\"8461\"\u003eInverter-Driven Heat Pumps\u003c\/li\u003e\n\u003cli data-section-id=\"ff8tkv\" data-start=\"8462\" data-end=\"8505\"\u003eHeat Pumps Requiring Type B-HP Protection\u003c\/li\u003e\n\u003cli data-section-id=\"1ggy3ie\" data-start=\"8506\" data-end=\"8536\"\u003eDedicated Heat Pump Supplies\u003c\/li\u003e\n\u003cli data-section-id=\"f5jc1p\" data-start=\"8537\" data-end=\"8567\"\u003eIP65 Heat Pump Installations\u003c\/li\u003e\n\u003cli data-section-id=\"z5dl1r\" data-start=\"8568\" data-end=\"8596\"\u003eHeat Pump Control Circuits\u003c\/li\u003e\n\u003cli data-section-id=\"s4lcsi\" data-start=\"8597\" data-end=\"8624\"\u003eImmersion Heater Circuits\u003c\/li\u003e\n\u003cli data-section-id=\"1149avd\" data-start=\"8625\" data-end=\"8651\"\u003eIntegral Heater Circuits\u003c\/li\u003e\n\u003cli data-section-id=\"1t0x32h\" data-start=\"8652\" data-end=\"8686\"\u003eDomestic Heat Pump Installations\u003c\/li\u003e\n\u003cli data-section-id=\"4llumz\" data-start=\"8687\" data-end=\"8723\"\u003eCommercial Heat Pump Installations\u003c\/li\u003e\n\u003cli data-section-id=\"18xptev\" data-start=\"8724\" data-end=\"8751\"\u003eRenewable Heating Systems\u003c\/li\u003e\n\u003cli data-section-id=\"1d0mm9h\" data-start=\"8752\" data-end=\"8786\"\u003eLow-Carbon Heating Installations\u003c\/li\u003e\n\u003cli data-section-id=\"2lbvu3\" data-start=\"8787\" data-end=\"8816\"\u003eHeat Pump Retrofit Projects\u003c\/li\u003e\n\u003cli data-section-id=\"l467wg\" data-start=\"8817\" data-end=\"8852\"\u003eNew-Build Heat Pump Installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"rt9486\" dir=\"auto\" data-start=\"8854\" data-end=\"8894\"\u003eWhy Choose the Lewden HPPO-07MG-AC16?\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"8896\" data-end=\"9051\"\u003eThe \u003cstrong data-start=\"8900\" data-end=\"8925\"\u003eLewden HPPO-07MG-AC16\u003c\/strong\u003e combines specialist heat pump circuit protection with the increased environmental protection of the \u003cstrong data-start=\"9026\" data-end=\"9050\"\u003ePRO65 IP65 enclosure\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"9053\" data-end=\"9345\"\u003eIts principal heat pump circuit is protected by a \u003cstrong data-start=\"9103\" data-end=\"9133\"\u003e16A C Curve Type B-HP RCBO\u003c\/strong\u003e, providing the enhanced residual-current characteristics required by compatible inverter-driven heat pumps. Dedicated \u003cstrong data-start=\"9252\" data-end=\"9279\"\u003eB6 and B20 Type A RCBOs\u003c\/strong\u003e are also supplied for the controls and immersion heater circuits.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"9347\" data-end=\"9508\"\u003eA \u003cstrong data-start=\"9349\" data-end=\"9384\"\u003e100A main switch and Type 2 SPD\u003c\/strong\u003e complete the core configuration, while \u003cstrong data-start=\"9424\" data-end=\"9441\"\u003e7 usable ways\u003c\/strong\u003e provide valuable spare capacity for additional heat pump circuits.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"9510\" data-end=\"9835\"\u003eFor installers working with a heat pump manufacturer that specifies a \u003cstrong data-start=\"9580\" data-end=\"9624\"\u003e16A enhanced Type B-HP protective device\u003c\/strong\u003e, the HPPO-07MG-AC16 provides a compact, pre-configured and IP65-rated solution for bringing the principal protection and distribution equipment together in one enclosure.\u003c\/p\u003e","brand":"Lewden","offers":[{"title":"Default Title","offer_id":54919744225626,"sku":"BHPPO-07MG-AC16","price":283.39,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/BHPPO-07MG-AC16__CAL_open.png?v=1791375892","url":"https:\/\/account.alertelectrical.com\/products\/lewden-hppo-07mg-ac16-pro65-7-way-ip65-heat-pump-consumer-unit-with-c16-type-b-hp-rcbo-b6-b20-rcbos-and-spd","provider":"Alert Electrical","version":"1.0","type":"link"}