{"product_id":"live-electrical-cn106b-6a-b-curve-double-pole-bi-directional-mcb-for-srn-consumer-units","title":"Live Electrical CN106B 6A B Curve Double Pole Bi-Directional MCB for SRN Consumer Units","description":"\u003ch1 class=\"MsoNormal\"\u003eLive Electrical CN106B 6A B Curve Double Pole Bi-Directional MCB for SRN Consumer Units\u003c\/h1\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e6A 2 Pole Bi-Directional B Curve MCB for Compatible Live Electrical SRN Consumer Units\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLive Electrical CN106B\u003c\/b\u003e is a \u003cb\u003e6A B Curve double pole bi-directional miniature circuit breaker (MCB)\u003c\/b\u003e designed specifically for use with compatible \u003cb\u003eLive Electrical SRN consumer units and double pole busbar arrangements\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eRated at \u003cb\u003e230V\u003c\/b\u003e with a \u003cb\u003e6kA fault current rating\u003c\/b\u003e, the CN106B provides circuit protection for suitable low-current final circuits while switching both poles. Its \u003cb\u003ebi-directional design\u003c\/b\u003e allows current flow in either direction where required by the compatible installation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe CN106B is intended specifically for the Live Electrical SRN consumer unit system and should be used with the appropriate SRN board and compatible Live Electrical busbar arrangement.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003eLive Electrical CN106B\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003e6A Current Rating\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003eB Curve Tripping Characteristic\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003eDouble Pole \/ 2P Configuration\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003eBi-Directional MCB\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003e6kA Fault Current Rating\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003e230V Rated\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003eMiniature Circuit Breaker\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003eDesigned for Live Electrical SRN Consumer Units\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003eCompatible with Appropriate Live Electrical SRN Busbars\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003eSuitable for Compatible Double Pole Busbar Arrangements\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003eDesigned for Appropriate Low-Current Final Circuits\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003eCircuit Overcurrent Protection\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003eCompact Consumer Unit Protection Device\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e6A Current Rating\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eCN106B has a rated current of 6A\u003c\/b\u003e, making it suitable for appropriately designed circuits requiring a 6A protective device.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eTypical applications for a 6A MCB can include suitable lighting and other low-current final circuits, although the correct protective device must always be determined from the circuit design, cable characteristics, connected load and applicable wiring requirements.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eB Curve Tripping Characteristic\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe CN106B features a \u003cb\u003eB Curve tripping characteristic\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eB Curve MCBs are widely used for suitable circuits with relatively low inrush currents, making this device particularly relevant to appropriately designed general-purpose and lighting applications.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe required MCB curve should always be selected according to the characteristics of the connected load and electrical installation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDouble Pole Protection\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eUnlike a conventional single-pole MCB, the \u003cb\u003eLive Electrical CN106B has a 2P double pole configuration\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis makes it suitable for the compatible double pole arrangement used within the relevant Live Electrical SRN consumer unit system.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eCorrect compatibility with the consumer unit, busbar and circuit arrangement should be confirmed before installation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eBi-Directional Design\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eCN106B is bi-directional\u003c\/b\u003e, allowing it to operate with current flow in either direction when installed as part of a compatible system.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis is an increasingly important consideration when specifying protective devices for modern electrical installations, particularly where the intended circuit arrangement requires a protective device approved for bi-directional operation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe bi-directional capability should not, however, be taken to mean that the CN106B is universally compatible with other consumer unit systems.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDesigned for Live Electrical SRN Consumer Units\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eCN106B is designed specifically for compatible Live Electrical SRN consumer units\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis compatibility is an important part of the product specification. Protective devices should not be assumed to be interchangeable between consumer unit manufacturers or product ranges simply because their physical dimensions appear similar.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor this reason, the CN106B should be selected for an appropriate \u003cb\u003eLive Electrical SRN board and compatible SRN busbar arrangement\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCompatible Double Pole Busbar Arrangement\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe device is intended for use with the appropriate \u003cb\u003eLive Electrical SRN double pole busbar system\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eUsing the correct matched protective device and busbar arrangement helps ensure the consumer unit is assembled in accordance with its intended system design.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWhen replacing or adding an MCB, the exact consumer unit and busbar compatibility should therefore be checked rather than selecting solely by current rating.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e6kA Fault Current Rating\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe CN106B has a stated \u003cb\u003e6kA fault current rating\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis is an important electrical characteristic when selecting a protective device, and suitability must be assessed as part of the overall electrical installation design.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e230V Rated\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe MCB is rated at \u003cb\u003e230V\u003c\/b\u003e, making it suitable for the intended compatible low-voltage electrical distribution application.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eVoltage, prospective fault current, circuit configuration and the characteristics of the connected load should all be considered when specifying the protective device.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eMCB Circuit Protection\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAs a miniature circuit breaker, the CN106B is intended to provide \u003cb\u003eovercurrent protection\u003c\/b\u003e for an appropriately designed circuit.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAn MCB is distinct from an RCBO or RCD. Where additional residual-current protection is required, the complete protective arrangement of the circuit must be considered.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis distinction is particularly important when replacing devices within an existing consumer unit.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eSpecifications\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eBrand:\u003c\/b\u003e Live Electrical\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eProduct Code:\u003c\/b\u003e CN106B\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eProduct Type:\u003c\/b\u003e Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eSeries Compatibility:\u003c\/b\u003e Live Electrical SRN Consumer Units\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eCurrent Rating:\u003c\/b\u003e 6A\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eTripping Curve:\u003c\/b\u003e B Curve\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eNumber of Poles:\u003c\/b\u003e 2P \/ Double Pole\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eDirectionality:\u003c\/b\u003e Bi-Directional\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eFault Current Rating:\u003c\/b\u003e 6kA\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eRated Voltage:\u003c\/b\u003e 230V\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eBusbar Compatibility:\u003c\/b\u003e Compatible Live Electrical SRN Busbar Arrangement\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eApplication:\u003c\/b\u003e Circuit Overcurrent Protection\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eConsumer Unit Compatibility:\u003c\/b\u003e Live Electrical SRN Consumer Units Only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eImportant Compatibility Information\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLive Electrical CN106B is intended for compatible Live Electrical SRN consumer units\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIt should not be described or sold as a universal 6A MCB for arbitrary consumer units.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBefore ordering as a replacement or additional protective device, the existing consumer unit range, busbar arrangement and device compatibility should be confirmed.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSuitable Applications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list 36.0pt;\"\u003eLive Electrical SRN Consumer Units\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list 36.0pt;\"\u003eCompatible Live Electrical SRN Distribution Boards\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list 36.0pt;\"\u003eCompatible Double Pole Busbar Arrangements\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list 36.0pt;\"\u003eAppropriate 6A Final Circuits\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list 36.0pt;\"\u003eSuitable Lighting Circuits\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list 36.0pt;\"\u003eDomestic Electrical Installations\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list 36.0pt;\"\u003eResidential Electrical Distribution\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list 36.0pt;\"\u003eNew-Build Electrical Installations\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list 36.0pt;\"\u003eConsumer Unit Upgrades\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list 36.0pt;\"\u003eReplacement SRN Protective Devices\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list 36.0pt;\"\u003eAppropriate Commercial Electrical Installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eWhy Choose the Live Electrical CN106B?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLive Electrical CN106B\u003c\/b\u003e is the appropriate choice when a \u003cb\u003e6A B Curve double pole bi-directional MCB\u003c\/b\u003e is required for a compatible Live Electrical SRN consumer unit.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIts combination of a \u003cb\u003e6A current rating, B Curve characteristic, 2P configuration, bi-directional operation, 6kA fault current rating and 230V rating\u003c\/b\u003e provides the key characteristics required for its intended SRN application.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eMost importantly, the device is specifically designed around the \u003cb\u003eLive Electrical SRN consumer unit and compatible busbar system\u003c\/b\u003e, helping customers and installers select the correct protective device rather than relying on a visually similar MCB from another range.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor compatible SRN installations requiring a \u003cb\u003e6A double pole B Curve MCB\u003c\/b\u003e, the Live Electrical CN106B provides a purpose-designed solution.\u003c\/p\u003e","brand":"Live Electrical","offers":[{"title":"Default Title","offer_id":54763083268442,"sku":"CN106B","price":7.22,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/Live_Electrical_CN106B_6A_B_Curve_2P_Bi-Directional_MCB.webp?v=1789049291","url":"https:\/\/account.alertelectrical.com\/products\/live-electrical-cn106b-6a-b-curve-double-pole-bi-directional-mcb-for-srn-consumer-units","provider":"Alert Electrical","version":"1.0","type":"link"}