{"product_id":"navitas-50a-10ka-single-pole-b-curve-type-a-tall-rcbo-n350br-t","title":"Navitas 50A 10kA Single Pole B Curve Type A Tall RCBO | N350BR-T","description":"\u003ch1 class=\"MsoNormal\"\u003eNavitas 50A 10kA Single Pole B Curve Type A Tall RCBO | N350BR-T\u003c\/h1\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003e50A 30mA Type A 10kA Single Pole \u0026amp; Neutral Tall RCBO – B Curve\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Navitas N350BR-T is a premium 50A Type A 30mA RCBO, providing combined overload, short circuit and residual current protection within a single compact device. Designed with a 10kA breaking capacity, it is ideal for commercial, industrial and higher fault current installations where enhanced circuit protection is required.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFeaturing a B Curve tripping characteristic, the N350BR-T is ideally suited to lighting circuits, control circuits and other low current applications. The integrated Type A residual current protection detects both alternating current (AC) and pulsating direct current (DC) residual faults generated by today's electronic equipment, making it suitable for modern electrical installations.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eLike every device in the Navitas protection range, each RCBO is individually tested and independently certified to deliver reliable, consistent performance. Backed by a 5-year manufacturer's warranty, the N350BR-T provides dependable protection for professional installations.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAvailable now from Alert Electrical your trusted supplier of professional circuit protection products.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003e50A Rated Current\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003e30mA Residual Current Protection\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003eType A RCBO\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003e10kA Breaking Capacity\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003eB Curve Tripping Characteristic\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003eSingle Pole + Neutral (1P+N)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003eIndividual Circuit Protection\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003eFault Current Indicator\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003eDIN Rail Mounted\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003e18mm Wide Tall RCBO\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003eIndividually Tested\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003eBS EN 61009-1 Compliant\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\"\u003e5 Year Manufacturer Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003eCombined Circuit Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe N350BR-T combines three essential protective functions within a single device:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo2; tab-stops: list 36.0pt;\"\u003eOverload Protection\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo2; tab-stops: list 36.0pt;\"\u003eShort Circuit Protection\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo2; tab-stops: list 36.0pt;\"\u003eResidual Current Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eBy protecting each circuit individually, faults can be isolated without unnecessarily disconnecting other circuits within the installation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003eType A Residual Current Detection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe integrated Type A residual current protection detects:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo3; tab-stops: list 36.0pt;\"\u003eAlternating Current (AC) residual faults\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo3; tab-stops: list 36.0pt;\"\u003ePulsating Direct Current (DC) residual faults\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eMaking the RCBO suitable for modern installations containing electronic equipment such as LED lighting, control systems and power supplies.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e10kA Breaking Capacity\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWith a 10kA short circuit capacity, the N350BR-T is designed for installations where higher prospective fault currents may be present.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003eThis makes it particularly suitable for:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l5 level1 lfo4; tab-stops: list 36.0pt;\"\u003eCommercial buildings\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l5 level1 lfo4; tab-stops: list 36.0pt;\"\u003eIndustrial installations\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l5 level1 lfo4; tab-stops: list 36.0pt;\"\u003eLarger distribution systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l5 level1 lfo4; tab-stops: list 36.0pt;\"\u003eHigh fault level electrical networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003eB Curve Performance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe B Curve tripping characteristic is ideal for circuits with standard inrush currents, including:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo5; tab-stops: list 36.0pt;\"\u003eLighting circuits\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo5; tab-stops: list 36.0pt;\"\u003eEmergency lighting\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo5; tab-stops: list 36.0pt;\"\u003eSmoke alarms\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo5; tab-stops: list 36.0pt;\"\u003eControl circuits\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo5; tab-stops: list 36.0pt;\"\u003eBuilding management systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo5; tab-stops: list 36.0pt;\"\u003eSecurity systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo5; tab-stops: list 36.0pt;\"\u003eSmall power circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eFor applications with higher inrush currents, such as large LED drivers or contactors, a C Curve RCBO may be more appropriate.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003eSpecifications\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo6; tab-stops: list 36.0pt;\"\u003eBrand: Navitas\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo6; tab-stops: list 36.0pt;\"\u003eProduct Code: N350BR-T\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo6; tab-stops: list 36.0pt;\"\u003eProduct Type: Tall RCBO\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo6; tab-stops: list 36.0pt;\"\u003eRated Current: 50A\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo6; tab-stops: list 36.0pt;\"\u003eResidual Current Rating: 30mA\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo6; tab-stops: list 36.0pt;\"\u003eRCBO Type: Type A\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo6; tab-stops: list 36.0pt;\"\u003eTripping Curve: B Curve\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo6; tab-stops: list 36.0pt;\"\u003eBreaking Capacity: 10kA\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo6; tab-stops: list 36.0pt;\"\u003ePoles: 1P + N\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo6; tab-stops: list 36.0pt;\"\u003eRated Voltage: 240V AC\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo6; tab-stops: list 36.0pt;\"\u003eFrequency: 50\/60Hz\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo6; tab-stops: list 36.0pt;\"\u003eMounting: DIN Rail EN 60715 (35mm)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo6; tab-stops: list 36.0pt;\"\u003eWidth: 18mm\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo6; tab-stops: list 36.0pt;\"\u003eHeight: 113mm\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo6; tab-stops: list 36.0pt;\"\u003eDepth: 73.4mm\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo6; tab-stops: list 36.0pt;\"\u003eWeight: 0.168kg\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo6; tab-stops: list 36.0pt;\"\u003eTightening Torque: 2.0Nm (Line Lower), 1.2Nm (Neutral Upper)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo6; tab-stops: list 36.0pt;\"\u003eFault Current Indicator: Yes\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo6; tab-stops: list 36.0pt;\"\u003eIP Rating: IP20\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo6; tab-stops: list 36.0pt;\"\u003eStandard: BS EN 61009-1\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo6; tab-stops: list 36.0pt;\"\u003eCountry of Origin: PRC\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo6; tab-stops: list 36.0pt;\"\u003eWarranty: 5 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003eIdeal Applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l6 level1 lfo7; tab-stops: list 36.0pt;\"\u003eCommercial Lighting Circuits\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l6 level1 lfo7; tab-stops: list 36.0pt;\"\u003eIndustrial Lighting\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l6 level1 lfo7; tab-stops: list 36.0pt;\"\u003eEmergency Lighting Systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l6 level1 lfo7; tab-stops: list 36.0pt;\"\u003eSmoke Alarm Circuits\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l6 level1 lfo7; tab-stops: list 36.0pt;\"\u003eControl Circuits\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l6 level1 lfo7; tab-stops: list 36.0pt;\"\u003eBuilding Management Systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l6 level1 lfo7; tab-stops: list 36.0pt;\"\u003eSecurity Systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l6 level1 lfo7; tab-stops: list 36.0pt;\"\u003eSmall Power Circuits\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l6 level1 lfo7; tab-stops: list 36.0pt;\"\u003eCommercial Distribution Boards\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l6 level1 lfo7; tab-stops: list 36.0pt;\"\u003eDistribution Board Upgrades\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l6 level1 lfo7; tab-stops: list 36.0pt;\"\u003eNew Commercial Installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003eWhy Buy the Navitas N350BR-T?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Navitas N350BR-T delivers reliable protection for low current circuits by combining overload, short circuit and residual current protection in a single compact device. With its 10kA breaking capacity, Type A residual current detection, B Curve tripping characteristic and individual circuit protection, it is an ideal choice for commercial and industrial electrical installations. Every device is individually tested and backed by a 5-year warranty, ensuring dependable long-term performance.\u003c\/p\u003e","brand":"Navitas Circuit Protection","offers":[{"title":"Default Title","offer_id":54481290330458,"sku":"N350BR-T","price":21.94,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/6232\/6106\/files\/N350BR-T50A30mAATYPE.png?v=1785242724","url":"https:\/\/account.alertelectrical.com\/products\/navitas-50a-10ka-single-pole-b-curve-type-a-tall-rcbo-n350br-t","provider":"Alert Electrical","version":"1.0","type":"link"}